Technical Data
Installation instructions
9
2.3
Voltage and switching capacity - electrical load
Designation
Value
Nominal Voltage
400 V 3 N ~ 50Hz
Oven
3x 230 V~ max. 3x 3 kW (AC1) / 3x 0,55kW (AC3) / 3x 0,75kW (AC15)
(Inrush current max. 30A for 5ms)
Evaporator
1)
230 V~ max. 3 kW (Inrush current max. 30A for 5ms)
Infrared
2)
230 V~ max. 3 kW (Inrush current max. 120A for 5ms)
For full-spectrum emitters max. 1,5kW
PS1 (FLE-STB)
230 V~ max. 60 W (Inrush current max. 30A for 5ms)
Fan
230 V~ max.
15W…120 W (Inrush current max. 10A for 5ms)
Cabin Light
230 V~ max.
15W…120 W (Inrush current max. 10A for 5ms)
Cleaning Light
230 V~ max. 120 W (Inrush current max. 10A for 5ms)
Table 3: Technical data
– voltages and switching capacity consumer
1) Only in controls with the bathing option "Sauna with humidity"
2) Only in controls with the bathing option "Infrared
”
NOTE!
FASEL additionally offers a extension power unit for loads of 9 kW, 18
kW and 24 kW.
2.4
If the sauna control device is installed in the technical room
If the sauna
control device
is not directly
installed on the
outer wall of the
cabin
The control device can be installed directly on the outer side of the cabin or at another
location, however not within the cabin. If the installation is not done directly on the outer
wall of the cabin then the following points should be noted:
◼
Lay the signal cables separately from the power line.
◼
Do not lay the signal cables parallel to the power line.
◼
Install a distribution box for the signal lines and another one for the power lines as
per Figure 1
◼
Note EN 60335-2-53 for remote start