ATTENTION:

Always ensure that the fluid control valve is close before use. 

This bleeder operates under pressure. It is 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FILLING PROCEDURE 

ATTENTION 

                    

POWER SWITCH MUST BE OFF 

1. 

Remove ne fluid cap at the back of the unit and fill the unit with new brake fluid 

2. 

To fill in just enough fluid for each service is recommended to prevent contamination from the air. 

OPERATING INSTRUCTION 

IMPORTANT: 

Each time the bleeder is filled with new brake fluid, air must be purged from the fluid supply hose before

 

connecting to the vehicle. Hold over a waste oil container (to collect any brake fluid that is forced out). Connect the unit 

to battery. Switch on the power switch to allow air to escape. When brake fluid is free flowing, turn off power switch. 

1. 

Install adaptor to the master cylinder of the brake system. 

2. 

Connect the bleeder to the battery and connect quick coupler to the adaptor. The unit woking pressure is setted at 2 

bar.  Adjust  pressure  regulator  on  the  panel  while  the  power  is  on  to  accommodate  the  requirement  of  different 

vehicles. The excess fluid will be return back to the new fluid tank. 

3. 

Open brake nipple and connect to the bleeding bottle. Switch on the power and fluid control valve to start brake fluid 

change. Once seeing new fluid coming into the bottle, turn off the power. Repeat process on all 4 wheels (in any 

order). 

4. 

Once  process  is  complete,  turn  off  the  power  and  fluid  control  valve  to  release  the  pressure.  Disconnect  hose 

assembly from the adaptor and take adaptor off vehicle. Replace the master cylinder cap on the vehicle. 

DESCRIPTION AND OPERATION 

F

G

 1

78

/S

F

 

 B

R

A

K

E

 B

L

E

E

D

E

R

 

Содержание FG 178/SF

Страница 1: ...The reproduction of this document even in partial form is prohibited without the Fasangas S r l authorization BRAKE BLEEDER 12V DC BRAKE BLEEDER Rev 1 012021 FG 178 SF ...

Страница 2: ...mply with the instructions and warnings provided use of non original accessories unauthorized modifications or interventions on the product etc Model FG 178 SF Type automatic brake bleeder Power supply 12V DC Tank capacity 5 liters Size 830x330x290 mm Weight 13 20 kg 29 lbs Max working pressure 2 bar Automatic stop at 10 of the tank ACCESSORIES 12V power cable fluid supply hose 2 adapters for mast...

Страница 3: ...d is free flowing turn off power switch 1 Install adaptor to the master cylinder of the brake system 2 Connect the bleeder to the battery and connect quick coupler to the adaptor The unit woking pressure is setted at 2 bar Adjust pressure regulator on the panel while the power is on to accommodate the requirement of different vehicles The excess fluid will be return back to the new fluid tank 3 Op...

Страница 4: ...ective EN 55014 2 1997 A1 A2 This instrument is warranted to be free from defects in materials and workmanship for a normal use of service for a period of one year Any instrument found detective within one year from the delivery date and returned to the factory with transportation charges prepaid will be repaired adjusted or replaced at no charge to the original purchaser This warranty e defect ha...