Control Panel
】
1.
Indicators
(1). When the power is turned on, the right side of the screen shows the number of
people and the number of alarm, the left side shows the standby lights and alarm
indicator
(2). The panel display in the standby indicator lights and alarm indicator, when
there is no metal objects through, only one to two rows of red and green light;
when a metal object through, all the red alarm light flashes, while the green
standby indicator lights goes out and issue alarm sound
(3). Signal strength meter is to the right of alarm panel. Only one or two LEDs are
lighted when no illicit metal object is passing through. If there are some illicit
metal objects is passing through, all the red LEDs of the signal strength meter will
flash, and the electronics sends out alarm.
The door has four location lights, it is divided into six districts according to the
door from bottom to top, and it is divided into three districts from left to right, a
total of 6/18 locations. Its role is to accurately show the metal objects to be
detected in the corresponding position on the human body.
2.
Digitron Display
It is a LED display. Simple, easy to operate.
3.
Keyboard operation
(1) ENT
The ENT key has 3 functions in normal operation. (1)
Confirmation function
:
After entering the power-on password on the main guide interface, press the ENT
key to confirm the entry into the conventional setting interface; (2)
Save setting
function
: modified menu or parameter saving; (3)
Switch function
. For example:
when the user sets the sensitivity, switch the area where the sensitivity needs to be
adjusted.
(2) SEL
The SEL key has 3 functions in normal operation. (1)
Switching function
. For
example: the user switches the number when setting the password; switches the
number when setting the tone; (2)
Adjustment function
; for example: when the
user adjusts the sensitivity / temperature in the area, the user is given the function
of upward adjustment (
↑
); (3)
To call up the frequency setting
, long press this
button after guiding the main interface to call up the hidden frequency setting
interface.
(3) ADJ
In normal operation, the ADJ key has 3 functions: (1)
Adjustment function
: when
the user adjusts the sensitivity / frequency / temperature, the user is given the
function of down adjustment (
↓
), which can be used Adjust the number; (2)
Enter
the general setting interface
: Press this button on the main interface to call up the