background image

1

GROWSPAN

 GOTHIC PRO GREENHOUSES AND SYSTEMS

Revision date: 06.06.18    113836_37_38_39

STK# 

  DIMENSIONS

113836C 

          20' W x 12' H x 28' L

113837C 

          20' W x 12' H x 36' L

113838C 

          20' W x 12' H x 48' L

113839C 

          20' W x 12' H x 72' L

Photo may show a different but similar model.

Film Cover with Film Roll-Up Side Panels

©2018 Growers Supply

All Rights Reserved. Reproduction 

is prohibited without permission.

GrowSpan

 

Gothic Pro Greenhouses and Systems

Содержание Growers supply GrowSpan Gothic Pro

Страница 1: ...x 12 H x 28 L 113837C 20 W x 12 H x 36 L 113838C 20 W x 12 H x 48 L 113839C 20 W x 12 H x 72 L Photo may show a different but similar model Film Cover with Film Roll Up Side Panels 2018 Growers Suppl...

Страница 2: ...hether your selected location is the best location Never erect the structure under power lines Identify whether underground cables and pipes are present before preparing the site or anchoring the stru...

Страница 3: ...Band Clamp Clamp used to connect end wall framing to rafter pipe In some cases band clamps are also used to connect diagonal struts Clip or Fabric Clip A short half section piece of conduit cut length...

Страница 4: ...diagrams for clarification or contact Customer Service NOTE At this time you do not need to open the plastic bags containing smaller parts such as fasteners or washers if equipped SPECIAL NOTE Baseboa...

Страница 5: ...Channel Spring CC6212 Fabric Clip FA4482B Tek Screw QH1402 Band Clamp 102548 Cross Connector 104074 Square to Round Tube Connect Bracket 102856 End Clamp FAH009B FALB01B Carriage Bolt Hex Nut 104624...

Страница 6: ...channel does not allow channel side out installation Use the diagrams on this page to install H channel with flat side facing out ATTENTION Use only 1 1 2 Tek screws to attach H channel to building f...

Страница 7: ...h assembly procedure 2 Assemble rafters and frame then square the frame 3 Prepare and attach end panels 4 Attach main cover and Twist of the Wrist assembly ATTENTION Position purlins evenly during fra...

Страница 8: ...the length center to center and drive the next corner ground post 6 Repeat the same step for the last corner post NOTE Distance measured diagonally between corner posts must be equal for building to b...

Страница 9: ...s for side struts are installed when the two 2 end rafters are set onto the ground posts 1 Select the five 5 pipes needed to assemble the first end rafter and arrange on a level surface 2 Slide four 4...

Страница 10: ...tead cross connectors are attached during the frame assembly 2 Insert swaged ends of rafter pipes into plain ends and secure each joint with an FA4482B Tek screw NOTE For longer frames it may be easie...

Страница 11: ...o ground posts using 5 16 x 2 1 2 FAG336B bolts and nuts FALB02B Use the top hole in ground post to secure rafter Rafter shown differs in design ATTENTION Stand the rafter so the nuts and bolts of the...

Страница 12: ...ross connector Interior Rafter Purlin 11 Secure cross connector to rafter and to purlin using FA4482B Tek screws See details in Quick Start section if needed 12 Repeat Steps 6 12 to install the first...

Страница 13: ...e customer and is attached at ground level along both sides of the frame Baseboards stabilize ground posts and prevent frame from working into ground when anchored Attach baseboards to frame on the ou...

Страница 14: ...rame If no baseboard is present attach strut to ground post using a FA4484B Tek screws or other customer supplied fasteners 4 Repeat above steps to attach the remaining side struts 5 After securing st...

Страница 15: ...abeled as NON CRITICAL on end frame diagrams when deciding where to install the additional horizontal framing for accessories Consult the diagrams in the Quick Start section showing the polycarbonate...

Страница 16: ...a 104779 tube 9 Measure the required length for the frame tube NOTE Length is measured between top of base tube and band clamp Step 7 on rafter 10 On assembled frame member mark length determined in...

Страница 17: ...FA4482B Tek screw through the back side of each door frame tube to secure the tube splice 19 Choose a 102897 tube for door header and cut length to the width of rough door opening Cut off part of swa...

Страница 18: ...ot tighten 31 Verify that frame member is plumb and use FA4482B Tek screws to secure 104624 fitting to base tube and frame member 32 Tighten band clamp and install an FA4482B short Tek screw through c...

Страница 19: ...optional double door is not present Consult the end frame diagram for additional information 1 Read note regarding installation of optional accessories at the beginning of the end wall installation s...

Страница 20: ...ial to protect them from dirt and damage Seal bottom edge of panels with white vent tape Consult polycarbonate panels Quick Start section for the location and lengths of each panel The diagrams are lo...

Страница 21: ...HANNEL TO END FRAME DO NOT install profile on bottom of end wall panels These edges are sealed with vent tape Always remove protective film Mark and install the UV protected side to the outside toward...

Страница 22: ...anel diagrams Cut upper panel to proper length Outside edges of panels are finished with aluminum u channel profile 104213 Consult diagrams for details U channel profile 104213 is also installed along...

Страница 23: ...needed Install panels with UV protected side to the outside toward the sun 5 Center the panel on the door frame 6 Use FA4484B Tek screws and neo bonded galvanized washers to attach panel to horizontal...

Страница 24: ...other door Locations of door hinges may vary 13 At top and sides of end wall door opening on the inside of the frame attach end cap 104548 and allow it to extend below header and into the frame openin...

Страница 25: ...er to the sides 4 Install inflation fan kit 5 Attach a second cover layer to the frame 6 Test the operation of the inflation fan kit 7 Install roll up side kits and test INSTALL POLYLATCH U CHANNEL 10...

Страница 26: ...rs The steps that follow describe one way to install cover film ATTENTION Install the IR film cover first Examine the IR film and install with the correct side facing in the direction indicated on the...

Страница 27: ...talling spring along top of first end rafter ensure an even amount of film is maintained along edge of greenhouse 7 Continue down both edges of first end rafter until entire length of film is secured...

Страница 28: ...nduit assembly varies with length of greenhouse Roll up conduit assemblies consist of multiple sections of swaged 1 315 pipe at 75 part 131S075 and one 1 additional plain 1 315 pipe at a shorter lengt...

Страница 29: ...m clockwise 5 Ensure that panel is even and secure film to the conduit using FA4482B Tek screws and CC6212 fabric clips evenly spaced along the conduit 6 Continue rolling excess film around conduit 7...

Страница 30: ...et and attach bearings In some instances bearings may come already attached Assemble bearings as follows if shipped unassembled NOTE Attach single bearings to sides of bracket and double bearings to m...

Страница 31: ...follows is applicable when the frame was constructed using wood boards under each rafter foot or if baseboards were installed If the shelter was constructed on concrete footings a concrete slab or on...

Страница 32: ...the tension as needed to prevent damage and wear Check connections and all fasteners to verify that they remain tight and in good condition Check polycarbonate panels if equipped to verify that these...

Страница 33: ...33 GROWSPAN GOTHIC PRO GREENHOUSES AND SYSTEMS Revision date 06 06 18 113836_37_38_39 Space below is reserved for customer notes...

Страница 34: ...8_39 Revision date 06 06 18 QUICK START GUIDE 20 Gothic Pro Greenhouse Frame shown may differ in length from actual frame Finished Grade Finished Grade Shelter Height 11 11 5 8 4 5 Sidewall 20 0 Shelt...

Страница 35: ...01D 20G166SS401D PURLIN CONNECTION SEE CONNECTION NOTE 20G166SS403 PURLIN CONNECTION SEE CONNECTION NOTE 166S064 PURLIN CONNECTION SEE CONNECTION NOTE 166S064 PURLIN CONNECTION SEE CONNECTION NOTE 102...

Страница 36: ...TEMS 36 113836_37_38_39 Revision date 06 06 18 SIDE PROFILE 113836 Baseboards Supplied by Customer 28 0 Shelter Length 4 0 Rafter Spacing 131S075 131S075 131S075 131S075 131P0495 4 Runs of Pipe Assemb...

Страница 37: ...EMS Revision date 06 06 18 113836_37_38_39 SIDE PROFILE 113837 Baseboards Supplied by Customer 36 0 Shelter Length 4 0 Rafter Spacing 131S075 131S075 131S075 131S075 131P0735 131S075 4 Runs of Pipe As...

Страница 38: ...36_37_38_39 Revision date 06 06 18 SIDE PROFILE 113838 48 0 Shelter Length 4 0 Rafter Spacing 131S075 131S075 131S075 131S075 131P0735 4 Runs of Pipe Assembly Used for Purlin runs 131S075 131S075 131S...

Страница 39: ...18 113836_37_38_39 SIDE PROFILE 113839 Baseboards Supplied by Customer 72 0 Shelter Length 4 0 Rafter Spacing 131S075 131S075 131S075 131S075 131P0735 131S075 131S075 131S075 131S075 131S075 131S075 1...

Страница 40: ...NS RAFTER GROUND POST VIEW 7 VERTICAL HORIZONTAL CONNECTION VIEW 4 PURLIN MID RAFTER CONNECTION VIEW 1 RAFTER STRUT CONNECTION VIEW 6 PURLIN END RAFTER CONNECTION VIEW 2 RAFTER ENDWALL CONNECTION VIEW...

Страница 41: ...L COLUMN RAFTER CHORD RAFTER CHORD TEK SCREW 14 X 1 RAFTER CHORD CONNECTION RAFTER STRUT VIEW 6 STRUT QH1304 QH1402 104675 1X 5 16 X 2 1 2 HEX BOLT RAFTER CHORD 1X 5 16 NUT ADDITIONAL HOLE FOR CUSTOME...

Страница 42: ...4 INSIDE DIM 48 C L C L 98 1 4 C L C L 48 C L C L 22 7 8 C L C L 22 7 8 C L C L 48 C L C L 25 1 8 C L C L VIEW 1 VIEW 3 VIEW 2 NOTE COLUMNS NOT DIMENIONED HAVE A NON CRITICAL PLACEMENT AND ARE USED FO...

Страница 43: ...43 GROWSPAN GOTHIC PRO GREENHOUSES AND SYSTEMS Revision date 06 06 18 113836_37_38_39 CONNECTION END WALL DETAILS...

Страница 44: ...ME DIAGRAM 48 C L C L 22 7 8 C L C L 25 1 8 C L C L 47 15 16 C L C L 25 1 8 C L C L 22 7 8 C L C L 48 C L C L NOTE COLUMNS NOT DIMENIONED HAVE A NON CRITICAL PLACEMENT AND ARE USED FOR POLYCARBONATE S...

Страница 45: ...H channel does not allow channel side out installation Use the diagrams on this page to install H channel with flat side facing out ATTENTION Use only 1 1 2 Tek screws to attach H channel to building...

Страница 46: ...06 06 18 POLYCARBONATE PANELS FRONT WITH DOORS H CHANNEL U CHANNEL USE 4 X 8 PANEL TO COVER A B 4 X 8 POLY 4 X 8 POLY ONE HALF 4 X 8 POLY 6 X 10 POLY 4 X 8 POLY ONE HALF 4 X 8 POLY 6 X 10 POLY PANEL B...

Страница 47: ...date 06 06 18 113836_37_38_39 POLYCARBONATE PANELS BACK NO DOORS H CHANNEL USE 4 X 8 PANEL TO COVER A B 6 X 10 POLY 4 X 8 POLY 4 X 8 POLY 4 X 8 POLY 4 X 8 POLY 6 X 10 POLY PANEL B PANEL A NOTE INSTALL...

Отзывы: