Specifications
Dimension (In.)
Rough
-
in Opening
Model
Prop Dia.
A
B
C
D
Height
Width
Ship Wt
Ship. Dims.
E
115236
36”
40 1/8
14
18
3/8
40 3/4
40 3/4
110
44x22x47
-
116188
48”
52 1/8
17
22
3/8
52 7/8
52 7/8
128
56x26x58
-
116193
48”
52 1/8
17
22
3/8
52 7/8
52 7/8
150
56x29x58
25
Getting Started
Tools/Materials Needed:
•
Drill/drill bits
•
5/16” nut driver
•
Construction screws
•
Caulk or sealant
Contents:
•
Galvanized box fan(1)
•
Instruction manual(1)
Inspection:
After unpacking your exhaust fan, carefully inspect for any damage that may have occurred during transit. Inspect for loose, missing or damaged
parts. If there is physical damage to any parts of the fan, a freight claim must be filed with the carrier. Check to assure that all bolts, screws and set
screws are securely tightened and have not become loose during transit. Retighten as required. Rotate propeller by hand to assure it turns freely.
General Safety Instructions
Danger:
Before installing or servicing, always lock out and tag power source. Do not rely on a switch as the only means
of disconnecting power. Failure to disconnect power can result in fire, electrical shock or serious injury. Motor will restart without
warning after thermal protector trips. Do not touch an operating motor as it may be hot enough to cause injury. Do not place any body
parts or objects in fan or drive components while fan is connected to a power source.
Warning:
1. Read and follow all instructions, cautions, dangers and warnings. Failure to do so could result in personal injury, death or property damage.
2. Make sure the electrical power source conforms to the requirement of the fan(s) as well as local codes.
3. Electrical connections, installation and maintenance must be done by qualified electrical personnel in accordance with all applicable codes and
ordinances.
4. Unit must be adequately grounded.
5. To reduce the risk of fire or electrical shock, do not expose this fan to water.
6. Do not touch electrically live components.
7. Free rotation of the propeller is critical. It must not touch any part of the venturi, framework or drive components.
8. Assure that all power cords do not come in contact with any sharp edges, hot surfaces or chemicals. Immediately replace any damaged cords.
Caution
:
OSHA requires OSHA compliant guards when fan is installed within 7ft of the floor or working level.