Copyright 1999 American Eagle Food Machinery, Inc. All Rights Reserved
4
ELECTRICAL CONNECTIONS (Cord Connected Mixers)
Before making the electrical connections, read the specifications on
the nameplate to make sure that they agree with those of your electric
service.
Electrical connections should be made by qualified workmen, who
will observe all applicable Safety Codes and the National Electrical
Code.
Be sure the planetary runs in the direction shown by the arrow in the
planetary head. Reverse direction is forbidden.
To start motor, push ON button. The speed selector handle must be at
one of the numbers indicating a speed, not at an intermediate
position.
BE
SURE
TO
CHECK
MIXING
ROTATION
WHEN
ELECTRICAL
CONNECTS ARE IN PLACE FOR ALL
THREE (3) PHASE RIGGING.
SPECIFICATIONS
Bowl Capacity Weight
(lbs.)
Electrical
H. P.
Speed Range
(RMP)
40 Qt
440
220-60-1
1.5
152-313-573(60HZ)
40 Qt
440
220-50-1
1.5
127-261-478(50HZ)