- 3 -

The keypad allows for the activation of 2
relays with programmable codes.

Technical data
Power supply

12Vac/dc ±10%

Stand-by current

0.06A

Maximum  current  consumption    0.15A
Contact ratings

12Vac - 2A

Number of codes for relay 1

12 (+ direct
activation)

Number of codes for relay 2

12 (+ direct
activation)

Activation time for each relay from 1 to 99 sec.

(or bistable)

Operating temperature

0° ÷ +40°C

Maximum allowable humidity 85% RH

Terminals
NC2

normally closed contact of relay 2

NA2

normally open contact of relay 2

C2

common contact of relay 2

NC1

normally closed contact of relay 1

NA1

normally open contact of relay 1

C1

common contact of relay 1
ground or alternate voltage input
positive or alternate voltage input

P2

activation of the relay 2; if momentarily
connected to ground it allows the activa-
tion for the programmed time

P1

activation of the relay 1; if momentarily
connected to ground it allows the activa-
tion for the programmed time

PROGRAMMING

Default programming
The article is supplied from the factory with
the following codes:

Programming code:

11

Activation code 1 of relay 1:

12345678

Other activation codes of relay 1
(from 2 to 12):

            none

Activation time code of relay 1: 01 (1 sec.)
Operating mode of relay 1: 00 (monostable)
Activation code 1 of relay 2:

90

Other activation codes of relay 2
(from 2 to 12):

            none

ACCESS CONTROL KEYPAD

Activation time code of relay 2: 01 (1 sec.)
Operating mode of relay 2: 00 (monostable)

All codes are user-modifiable.

Operating modes and programming codes
Monostable

00

Bistable

01

Monostable and direct activat. by key A 02
Bistable and direct activation by key A

03

Changing the programming code
To change the programming code:
- enter the actual programming code
- press key A (red LED flashes)
- enter 00
- press key A (red LED on)
- enter the new programming code with 1 to 8

digits (from 0 to 99999999)

- press key A (red LED flashes)
- enter 55
- press key A (red LED off).

Changing the activation codes of relay 1
To change the activation codes of relay 1:
- enter the programming code
- press key A (red LED flashes)
- enter 01 (identification code of relay 1)
- press key A (red LED on)
- enter a number with 1 to 8 digits to pro-

gramme code 1 (from 0 to 99999999)

- press key A
- enter a number with 1 to 8 digits to pro-

gramme code 2 (from 0 to 99999999)

- press key A
- enter a number with 1 to 8 digits to pro-

gramme code 3 (from 0 to 99999999)

- press key A
- repeat the operation to programme all codes

as necessary (max.12). When program-
ming is completed press key repeatedly
until the red LED starts flashing

- enter 55
- press A (red LED off).

Changing the activation codes of relay 2
To change the activation codes of relay 2
follow the procedure described above, chang-
ing the relay identification code (02 instead of
01).

Changing one relay activation code
To change one relay activation code, without
modifying the others:
- enter the programming code
- press key A (red LED flashes)
- enter 01 or 02 (for relay 1 or 2, respectively)
- press key A (red LED on)
- press key repeatedly to reach the code to

be changed

- enter a number with 1 to 8 digits (from 0 to

99999999)

- press key repeatedly until the red LED

starts flashing

- enter 55
- press key A (red LED off).

Example
To change activation code 7 of relay 2:
- enter the programming code
- press key A (red LED flashes)
- enter 02
- press key A (red LED on)
- press key six times
- enter a number with 1 to 8 digits
- press key six times (red LED flashes)
- enter 55
- press key A (red LED off).

Deleting one relay activation code
To delete one relay activation code, without
modifying the others:
- enter the programming code
- press key A (red LED flashes)
- enter 90
- press key A (red LED on)
- enter a 3-digit number “nxx”; indicates the

relay associated with the code to be deleted
(1 or 2); xx indicates the code to be deleted
(from 01 to 12)

- press key A (red LED flashes)
- enter 55
- press key A (red LED off).

Changing the relay activation time and mode
To change the relay activation time and mode:
- enter the programming code
- press key A (red LED flashes)
- enter 03
- press key A (red LED on)

(*) Cable in bold face type.

X . Y

F . H . C . 4 . 10

(*)  F . H

(*)  A . 

-

Terminals

Distance

50m

(mm²)

0.35

0.5

0.75

1.5

165 Ft

(AWG)

22

20

18

16

CABLES

100m

(mm²)

0.35

0.75

1

2.5

330 Ft

(AWG)

22

18

16

14

200m

(mm²)

0.35

1

2

-

660 Ft

(AWG)

22

16

14

-

Note. For distances longer than 100m (330ft) max 200m
(660ft) use twisted pair wire for conductores X and Y.