Faraday 8705 Скачать руководство пользователя страница 2

PAGE 2 OF 4

WIRING

Disconnect BATTERY and AC prior to working on equipment.

Electrical Connections

After you have set the 8705 address, connect the field wiring. There are three basic connections to the 8705:
initiating devices, addressable device circuit, and 24 VDC power. All terminals are power limited.

Initiating Devices  (See Figures 2 and 3)

The 8705 supports one zone of initiating devices in either Class A or Class B. The initiating devices are connected to
terminals 5–8 on the 8705 terminal block.  The 8705 is a polarity insensitive module and terminals 1 and 2 can be
connected to either line of the addressable device circuit. Figure 2 shows the Class A wiring. Figure 3 shows the
Class B wiring.

24 VDC Power

The 8705 receives its power from the 24 VDC power output on the control unit or auxiliary power supply that must be
power limited and UL listed for Fire Protective Signaling use. The 24 VDC power may be wired only as Class B.
Since the 8705 monitors the power at its screw terminals, an End of Line Relay is not required for supervision.

ELECTRICAL RATINGS

1

2

3

4

5

6

7

8

9

+

-

-

+

+

-

-

+

+

-

-

+

From the addressable device
circuit of a compatible control

unit or previous addressable

device

-

-

-

+

+

+

Ground (See notes 4 and 5)

End of Line

Resistor

3.6K, 1/4W

P/N 140-820185

To the next addressable

device

From the auxiliary power

supply output of the control

unit or an external 24VDC

power supply that must be

power limited and UL Listed
for Fire Protective Signaling

use.

Addressable Device Circuit

Initiating Device Circuit
Supervised (See note 3)

Line 1

Line 2

Line 1

Line 2

Figure 2

8705 Initiating Devices Wiring Diagram

Style D (Class A) Installation

Figure 3

8705 Initiating Devices Wiring Diagram

Style B (Class B) Installation

1

2

3

4

5

6

7

8

9

+

-

-

+

+

-

-

+

+

-

-

+

-

-

+

+

End of Line

Resistor

3.6K, 1/4W

P/N 140-820185

From the addressable device
circuit of a compatible control

unit or previous addressable

device

To the next addressable

device

From the auxiliary power

supply output of the control

unit or an external 24VDC

power supply that must be

power limited and UL Listed
for Fire Protective Signaling

use.

Addressable Device Circuit

Not Used

Line 1

Line 2

Line 1

Line 2

Ground (See notes 4 and 5)

Initiating Device Circuit
Supervised (See note 3)

NOTES:
1. All circuits are power limited.
2. See NFPA 72 Standard for the number of normally open contact devies allowed. See

UL Compatible Two-Wire Smoke and Heat Detectors for the list of compatible
devices.

3. Initiating Device Circuit cable requirements: Wire size 18 to 14 AWG
4. If Earth Ground is available, the green wire should be connected to earth ground.
5. If Earth Ground is NOT available, the IDC wiring should be limited to the same room.
6. The 8705 draws 1mA from the addressable device circuit.

:

e

n

o

Z

e

c

i

v

e

D

g

n

i

t

a

i

t

i

n

I

e

c

n

a

t

s

i

s

e

R

e

n

o

Z

.

x

a

M

l

a

t

o

T

s

m

h

o

5

3

e

g

n

a

R

e

g

a

t

l

o

V

y

r

o

s

i

v

r

e

p

u

S

C

D

V

5

.

4

2

-

8

1

t

n

e

r

r

u

C

e

n

o

Z

.

x

a

M

A

m

4

3

r

e

w

o

P

C

D

V

4

2

e

g

n

a

R

e

g

a

t

l

o

V

C

D

V

2

.

8

2

-

8

.

8

1

t

n

e

r

r

u

C

.

x

a

M

A

m

0

0

1

Отзывы: