Farad Super10 Скачать руководство пользователя страница 7

 

Output Voltage 

 
The Super10 super-cap module and transformer are fully optimized at a factory fixed 
voltage output. This output is mentioned at the back, see figure 1, position 3. 

Always 

check and double check

 that this output voltage matches the voltage input of the 

device it will be connected to. If these do not match connecting the power supply can 
result in permanent damage of the device it is connected to. Farad power supplies 
refuses every liability for damage to equipment due to an incorrect connected DC 
output voltage. 
 
Current rating of the Farad power supply should be higher than the factory 
recommended current. If the manufacturer does not give this value, it can be 
calculated from the power figure, as max current = max power / rated voltage. If this 
does not work, it also can be obtained by reading the original adapter. Please keep in 
mind adapter values are mostly very overrated, so mostly will give a far too high value. 
At the Farad website you can find a list of confirmed devices with proper voltage and 
connector ratings.  
 
If you are not sure, you can always try out with a Farad power supply, it is fully 
protected, so nothing will be damaged if too much current will be drawn. If it works it is 
ok. If you don’t feel safe about us, please ask your dealer, or directly at Farad, we are 
there to help you! 
 

Output Cable 

 
The power supply has a gold plated GX25-4 output connector. We have connected the 
+ voltage output to pin 1 and 3 and the GND to pin 2 and 4. 
 
The Super10 is standardly delivered with a Level 2 copper DC power cable, this can 
be upgraded to a silver cable. The Level 2 copper cable contains 2x18 times 24 AWG 
tin plated copper wires, the silver cable uses 12x2 0.4mm 99.9999% pure silver wire. 
Both cables are terminated with gold plated Oyaide 5.5/2.1 mm or 5.5/2.5 mm barrel 
connectors or other connectors at your choice.  
 
Any other connector (within normal connector prices) will be delivered at request at 
thew same price as the stock cables. Since this cable needs to be specially made for 
you delivery time is about 2-4 weeks after order.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Super10

Страница 1: ...1 Super10 Owner s manual...

Страница 2: ...ng Do not place the unit on a bed sofa rug or similar surface that could block the heatsink airflow If the component is placed in a bookcase or cabinet there must be ventilation of the cabinet to allo...

Страница 3: ...ment WEEE The products must be appropriately recycled or processed in accordance with these directives IMPORTANT NOTE Always switch off and mute devices when connecting or disconnecting the Farad powe...

Страница 4: ...ainst and shall have no liability for any failure of its Products to satisfactorily process any externally sourced data where such failure is attributable in whole or in part to the makeup of the data...

Страница 5: ...e original sales receipt of your power supply It is your best record of the date of purchase which you will need in the event warranty service is ever required When you have any problems with our equi...

Страница 6: ...g from you AC outlets Should you move your power supply to a country with other voltages or frequencies it is possible to reconfigure the power supply to these voltages Do not attempt this change of c...

Страница 7: ...alue At the Farad website you can find a list of confirmed devices with proper voltage and connector ratings If you are not sure you can always try out with a Farad power supply it is fully protected...

Страница 8: ...over of the power supply The Super10 needs a 6 3A slow blow 5x20 mm fuse for the 230Vac version and a 10A slow blow fuse for the 115Vac versions Please only do this if you know what you are doing othe...

Страница 9: ...current 3 Reset switch This switch resets the power supplies microprocessor After a reset the supply will start a new startup sequence It can be used to reset the supplied device or when changing betw...

Страница 10: ...ly When you have any questions about our power supplies please contact us at info Faradpowersupplies com with serial number stated at the back see figure 1 position 8 of the power supply We will reply...

Страница 11: ...re occurs contact your dealer or Farad directly at info faradpowersupplies com If the error is solved without anything connected please check the device on which the SUPER10 was connected or the DC c...

Страница 12: ...utput voltage Capacitance Max power consumption 5 16 7F 150W 7 12 5F 170W 9 10 0F 190W 12 8 3F 220W 15 7 1F 250W 19 5 6F 290W 24 4 5F 350W Any other voltage between 5V and 24V available on special req...