![FAR RAC 230 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/far/rac-230/rac-230_operating-instructions-and-spare-parts-list_3446257008.webp)
TOPPING UP THE OIL-DYNAMIC CIRCUIT
(fig.
f7
)
You need to top up the oil-dynamic circuit after a long period of work, when you note a power loss. Proceed as follows: by means
of a short jet of compressed air through hole (
C
) make the piston completely go back, unscrew (
A
) by a 12mm standard spanner
key, extract the seal and continue the oil topping up by means of the oil container (
B
) being part of the equipment which has pre-
liminarily been filled with hydraulic oil
PANOLIN HLP ISO 32.
This operation has to be carried out slowly in order to enabled the
air to come out of the tank. The procedure has been fulfilled when the oil level arrives t the threaded port. Then, fit the O-ring in
his seat and tighten the screw (
A
) with a torque of
min. 5 Nm to max. 8 Nm.
At this point, the topping up operating has been fin-
ished. Screw the riveting tool head (
B
) again on the body (
A
) and continue with the normal work cycle.
WARNING:
it is very important to follow the about mentioned instructions and use gloves. If you need to empty fully the hydraulic
circuit, you must put the oil in a suitable container and contact a Company that is authorized to discharge any waste.
Follow the prescriptions of the national laws for disposing of the riveting tool.
After disconnecting the tool from the pneumatic system, disassemble and split all the components according to the ma-
terial: steel, aluminium, plastic material, etc.
Then proceed to scrap the materials in accordance with current laws.
DISPOSAL OF THE RIVETING TOOL
Before disconnecting the compressed air hose, make
sure that it is not under pressure!
ATTENTION:
Make sure that the oil filter cap (
A
) is tightened at a torque corresponding to
Min. 5 Nm ÷ Max. 8 Nm.
We recommend to use oil
PANOLIN HLP ISO 32 DIN 51524-2/HLP
or similar.