16

 / 

54

Save

 

Auto

 

Provision

 

Information

 

Save

 

the

 

auto

 

provision

 

username

 

and

 

password

 

in

 

the

 

phone

 

until

 

the

 

server

 

url

 

changes

 

DHCP

 

Option

 

Option

 

Value

 

The

 

equipment

 

supports

 

configuration

 

from

 

Option

 

43,

 

Option

 

66,

 

or

 

a

 

Custom

 

DHCP

 

option.

 

It

 

may

 

also

 

be

 

disabled.

 

Custom

 

Option

 

Value

 

Custom

 

option

 

number.

 

Must

 

be

 

from

 

128

 

to

 

254.

 

SIP

 

Plug

 

and

 

Play

 

(PnP)

 

Enable

 

SIP

 

PnP

 

If

 

this

 

is

 

enabled,

 

the

 

equipment

 

will

 

send

 

SIP

 

SUBSCRIBE

 

messages

 

to

 

a

 

multicast

 

address

 

when

 

it

 

boots

 

up.

 

Any

 

SIP

 

server

 

understanding

 

that

 

message

 

will

 

reply

 

with

 

a

 

SIP

 

NOTIFY

 

message

 

containing

 

the

 

Auto

 

Provisioning

 

Server

 

URL

 

where

 

the

 

phones

 

can

 

request

 

their

 

configuration.

 

Server

 

Address

 

PnP

 

Server

 

Address

 

Server

 

Port

 

PnP

 

Server

 

Port

 

Transportation

 

Protocol

 

PnP

 

Transfer

 

protocol

 

 

UDP

 

or

 

TCP

 

Update

 

Interval

 

Interval

 

time

 

for

 

querying

 

PnP

 

server.

 

Default

 

is

 

1

 

hour.

 

Static

 

Provisioning

 

Server

 

Server

 

Address

 

Set

 

FTP/TFTP/HTTP

 

server

 

IP

 

address

 

for

 

auto

 

update.

 

The

 

address

 

can

 

be

 

an

 

IP

 

address

 

or

 

Domain

 

name

 

with

 

subdirectory.

 

Configuration

 

File

 

Name

 

Specify

 

configuration

 

file

 

name.

 

The

 

equipment

 

will

 

use

 

its

 

MAC

 

ID

 

as

 

the

 

config

 

file

 

name

 

if

 

this

 

is

 

blank.

 

Protocol

 

Type

 

Specify

 

the

 

Protocol

 

type

 

FTP,

 

TFTP

 

or

 

HTTP.

 

Update

 

Interval

 

Specify

 

the

 

update

 

interval

 

time.

 

Default

 

is

 

1

 

hour.

 

Update

 

Mode

 

1.

 

Disable

 

 

no

 

update

 

2.

 

Update

 

after

 

reboot

 

 

update

 

only

 

after

 

reboot.

 

3.

 

Update

 

at

 

time

 

interval

 

 

update

 

at

 

periodic

 

update

 

interval

 

TR069

 

Enable

 

TR069

 

Enable/Disable

 

TR069

 

configuration

 

ACS

 

Server

 

Type

 

Select

 

Common

 

or

 

CTC

 

ACS

 

Server

 

Type.

 

ACS

 

Server

 

URL

 

ACS

 

Server

 

URL.

 

ACS

 

User

 

User

 

name

 

for

 

ACS.

 

ACS

 

Password

 

ACS

 

Password.

 

TR069

 

Auto

 

Login

 

Enable/Disable

 

TR069

 

Auto

 

Login.

 

INFORM

 

Sending

 

Period

 

Time

 

between

 

transmissions

 

of

 

“Inform”

 

Unit

 

is

 

seconds.

 

 

Содержание i31S

Страница 1: ... 键入文字 i31S SIP Video DoorPhone User Manual V1 0 ...

Страница 2: ... 键入文字 Document VER Firmware VER Explanation Time V1 0 2 1 1 2898 Initial issue 20170629 ...

Страница 3: ...nternal components produce condense water vapor please open power use it after waiting for this product is natural drying 4 Please do not let non technical staff to remove or repair Improper repair may cause electric shock fire malfunction etc It will lead to injury accident or cause damage to your product 5 Do not use fingers pins wire other metal objects or foreign body into the vents and gaps I...

Страница 4: ...g instructions 8 2 QUICK SETTING 9 III BASIC OPERATION 10 1 ANSWER A CALL 10 2 CALL 10 3 END CALL 10 4 OPEN THE DOOR OPERATION 10 IV PAGE SETTINGS 11 1 BROWSER CONFIGURATION 11 2 PASSWORD CONFIGURATION 11 3 CONFIGURATION VIA WEB 12 1 System 12 a Information 12 b Account 13 c Configurations 14 d Upgrade 14 e Auto Provision 15 f Tools 17 2 Network 19 a Basic 19 b VPN 20 3 Line 22 a SIP 22 b Basic Se...

Страница 5: ... Action URL 39 f Time Date 39 5 EGS Access 41 6 EGS Logs 43 7 Function Key 44 8 Alert 46 V APPENDIX 49 1 TECHNICAL PARAMETERS 49 2 BASIC FUNCTIONS 50 3 SCHEMATIC DIAGRAM 50 VI OTHER INSTRUCTIONS 51 1 OPEN DOOR MODES 51 2 MANAGEMENT OF CARD 51 ...

Страница 6: ...nstallation comfortable keypad and low power consumption i31S voice access supports entrance guard control voice intercom ID card and keypad remote to open the door 1 Appearance of the product 2 Description Buttons and icons Description Function Numeric keyboard Input password to open the door or to call programmable keys Can be set to a variety of functions in order to meet the needs of different...

Страница 7: ...use the equipment please make the following installation 1 Confirm the connection Confirm whether the equipment of the power cord network cable electric lock control line connection and the boot up is normal Check the network state of light 1 Power Electric Lock Indoor switch port Voice access the power supply ways 12v DC or POE CN7 1 2 3 4 5 6 7 12V VSS NC COM NO S_IN S_OUT 12V 1A DC Electric loc...

Страница 8: ...nce can be connected When using the active mode it is 12V DC in output When using the passive mode output is short control normally open mode or normally close mode 3 Wiring instructions NO Normally Open Contact COM Common Contact NC Normally Close Contact Driving Mode Electric lock Jumper port Connections Active Passive No electricity when open When the power to open ...

Страница 9: ...d Internet online can be normal operated and complete the connection of the network hardware The product factory default network mode is DHCP Thus only connect equipment with DHCP network environment that network can be automatically connected Press and hold key for 3 seconds and the door phone will report the IP address by voice or use the iDoorPhoneNetworkScanner exe software to find the IP addr...

Страница 10: ...the list of access configuration and enable for remote calls to open the door 4 Swipe the RFID cards to open the door 5 By means of indoor switch to open the door 6 Private access code to open the door Enable for local authentication and set private access code Input the access code directly under standby mode to open the door In this way the door log will record corresponding card number and user...

Страница 11: ...in interface of the web page management Enter the user name and password and click the logon button to enter the settings screen 2 Password Configuration 设There are two levels of access root level and general level A user with root level access can browse and set all configuration parameters while a user with general level can set all configuration parameters except server parameters for SIP Defau...

Страница 12: ...isplay equipment model hardware version software version uptime Last uptime and MEMinfo Network Shows the configuration information for WAN port including connection mode of WAN port Static DHCP PPPoE MAC address IP address of WAN port SIP Accounts Shows the phone numbers and registration status for the 2 SIP LINES ...

Страница 13: ...sers depends on their needs and can modify existing user permission Account Field Name Explanation Change Web Authentication Password You Can modify the login password to the account Add New User You can add new user User Accounts Show the existing user information ...

Страница 14: ...lick on the choice and then choose Save Link As Import Configurations Browse to the config file and press Update to load it to the equipment Reset to factory defaults This will restore factory default and remove all configuration information d Upgrade Upgrade Field Name Explanation Software upgrade Browse to the firmware and press Update to load it to the equipment ...

Страница 15: ...on If the configuration downloaded and this configuration is the same the auto provision will stop If the endpoints confirm the configuration by the Digest method the configuration will not be upgraded unless it differs from the current configuration CPE Serial Number Serial number of the equipment Authentication Name Username for configuration server Used for FTP HTTP HTTPS If this is blank the p...

Страница 16: ...ol UDP or TCP Update Interval Interval time for querying PnP server Default is 1 hour Static Provisioning Server Server Address Set FTP TFTP HTTP server IP address for auto update The address can be an IP address or Domain name with subdirectory Configuration File Name Specify configuration file name The equipment will use its MAC ID as the config file name if this is blank Protocol Type Specify t...

Страница 17: ...Subscribe information to the FDMS server on a regular basis Unit seconds Doorphone Info Settings Community Name The name of the community where the device is installed Building Number The name of the building where the equipment is installed Room Number The name of the room where the equipment is installed f Tools ...

Страница 18: ...tly but needs attention Level 5 notice It is the normal but significant condition Level 6 Informational It is the normal daily messages Level 7 debug Debug messages normally used by system designer This level can only be displayed via telnet Tools Field Name Explanation Syslog Enable Syslog Enable or disable system log Server Address System log server IP address Server Port System log server port ...

Страница 19: ...he equipment supports three network modes Static IP Network parameters must be entered manually and will not change All parameters are provided by the ISP DHCP Network parameters are provided automatically by a DHCP server PPPoE Account and Password must be input manually These are provided by your ISP If Static IP is chosen the screen below will appear Enter values provided by the ISP DNS Server ...

Страница 20: ...dress is 192 168 1 70 and the port value is 8090 the accessing address is http 192 168 1 70 8090 HTTPS Port Port for HTTPS access Before using https an https authentication certification must be downloaded into the equipment Default value is 443 To enhance security change this from the default Note 1 Any changes made on this page require a reboot to become active 2 It is suggested that changes to ...

Страница 21: ... 键入文字 21 54 ...

Страница 22: ...be activated After the selection is made the configuration should be saved and the phone be rebooted Layer 2 Tunneling Protocol L2TP L2TP Server Address Set VPN L2TP Server IP address Authentication Name Set User Name access to VPN L2TP Server Authentication Password Set Password access to VPN L2TP Server Open VPN Files Upload or delete Open VPN Certification Files 3 Line a SIP Configure a SIP ser...

Страница 23: ... 键入文字 23 54 ...

Страница 24: ... is 5060 Realm Enter the SIP domain if requested by the service provider Codecs Settings Set the priority and availability of the codecs by adding or remove them from the list Advanced Settings Subscribe For Voice Message Enable the device to subscribe a voice message waiting notification if enabled the device will receive notification from the server if there is voice message waiting on the serve...

Страница 25: ...pecific Server Type Set the line to collaborate with specific server type Registration Expiration Set the SIP expiration interval Use VPN Set the line to use VPN restrict route Use STUN Set the line to use STUN for NAT traversal Convert URI Convert not digit and alphabet characters to hh hex code DTMF Type Set the DTMF type to be used for the line DTMF SIP INFO Mode Set the SIP INFO mode to send a...

Страница 26: ...able User Agent URI GRUU BLF Server The registered server will receive the subscription package from ordinary application of BLF phone Please enter the BLF server if the sever does not support subscription package the registered server and subscription server will be separated BLF List Number BLF List allows one BLF key to monitor the status of a group Multiple BLF lists are supported SIP Encrypti...

Страница 27: ... port used to send receive SIP messages Registration Failure Retry Interval Set the retry interval of SIP REGISTRATION when registration failed Enable Strict UA Match Enable or disable Strict UA Match STUN Settings Server Address STUN Server IP address Server Port STUN Server Port Default is 3478 ...

Страница 28: ...l more flexible Import Dial peer Table Field Name Explanation Select File Select an existing dialing rule file The file type must be a CSV Add Dial Peer Number In order to add an outgoing call number the outgoing call number can be divided into two types one is the exact match and after the exact match if the number is exactly the same as the user dialing the called number the device will use the ...

Страница 29: ...ing all number to change the actual call out the number 3 del delete the number before the n bit n by the replacement length set 4 rep xxx the number n before the number is replaced by xxx n is set by the replacement length For example if the user wants to dial the PSTN 010 62281493 through the floor service provided by the VoIP operator and the actual call should be 010 62281493 then we can confi...

Страница 30: ...le there are two actions and statuses door unlocking and door locking Each action might be triggered and changed to the other status After changed the status would be kept Initial Value is Monostable Switch On Duration Door unlocking time for Monostable mode only If the time is up the door would be locked automatically Initial Value is 5 seconds ...

Страница 31: ...cess Table enter Access Code for opening door during calls Disable Access Table enter Remote Password for opening door during calls Default Enable Description Device description displayed on IP scanning tool software Initial Value is i31S IP Door Phone Enable Open Log Server Enable or disable to connect with log server Address of Open Log Server Log server address IP or domain name Port of Open Lo...

Страница 32: ...e Set language of the voice prompt Enable Delay Start Enable or disable the start delay Delay Start Time Set start delay time Voice Read IP Enable or disable voice broadcast IP address Press to Send Enable or disable the Press to Send Initial Value is enable Block Out Settings Add or delete blocked numbers enter the prefix of numbers which should not be dialed by the phone For example if 001 is en...

Страница 33: ...t Ring Type Ring Sound There are 9 standard types and 3 User types G 729AB Payload Length G 729AB Payload Length Adjusts from 10 60 mSec Tone Standard Configure tone standard area G 722 Timestamps Choices are 160 20ms or 320 20ms G 723 1 Bit Rate Choices are 5 3kb s or 6 3kb s Speakerphone Volume Set the speaker calls the volume level MIC Input Volume Set the MIC calls the volume level Broadcast O...

Страница 34: ...mera is located Day Mode The camera s video screen is always colored if there is IR cut will be synchronized to switch Night Mode the camera s video screen is always black and white if there is IR cut will be synchronized switch White Balance Automatic Automatically adjusts according to the actual environment in which the camera is located Outdoor installed in the outdoor preferred Indoor installe...

Страница 35: ... D1 720 576 Frame Rate The larger the value is the more coherent the video would be got not recommend adjusted Bitrate Control CBR If the code rate bandwidth is insufficient it is preferred VBR Image quality is preferred not recommended Quality Video quality adjustment the better the quality needs to transfer faster Bit rate It is proportional to video file size not recommend adjusted I Frame Inte...

Страница 36: ...of the incoming flows of multicast RTP lower precedence than the current common calls device will automatically ignore the group RTP stream If the priority of the incoming flow of multicast RTP is higher than the current common calls priority device will automatically receive the group RTP stream and keep the current common calls in state You can also choose to disable in the receiving threshold d...

Страница 37: ... 1 Group 2 and Group 3 are your setting monitoring multicast name The group name will be displayed on the screen when you answer the multicast If you have not set the screen will display the IP port directly Purple part host port It is a set of addresses and ports to listen separated by a colon Pink part index priority Multicast is a sign of listening but also the monitoring multicast priority The...

Страница 38: ...se The purpose of setting monitoring multicast group 1 or 3 set up listening group of 1 or 3 multicast address multicast call All equipment has been a path or multi path multicast phone such as listening to multicast information group 2 If multicast is a new group of 1 because the priority group 1 is 2 higher than the current call priority group 2 3 so multicast call will can come in If multicast ...

Страница 39: ...4 e Action URL Action URL Event Settings URL for various actions performed by the phone These actions are recorded and sent as xml files to the server Sample format is http InternalServer FileName xml f Time Date ...

Страница 40: ...erver to get time synchronization Time zone Select the time zone Resync Period Time of re synchronization with time server Date Format Date Format Select the time date display format Daylight Saving Time Settings Location Select the user s time zone specific area DST Set Type Select automatic DST according to the preset rules of DST or the manually input rules Offset The DST offset time Month Star...

Страница 41: ... 41 54 Hour End The DST end hour Manual Time Settings The time set by hand need to disable SNTP service first Daylight Saving Time Settings 5 EGS Access EGS Access Field Name Explanation Import Access Table ...

Страница 42: ...ly 2 The user s private password should be input via keypad for local door unlocking The private password format is Location Access Code Position Card holder s position Double Auth When the feature is enabled private password inputting and RFID reading must be matched simultaneously for door unlocking Type Host the door phone would answer all call automatically Guest the door phone would ring for ...

Страница 43: ...lete would delete the admin card list of the selected ID cards Delete All Click Delete All to delete all admin card lists 6 EGS Logs According to open event log the device can record up to 150 thousands open event it would cover the old records after the records exceed 150 thousands Right click on the links to select saving target as the door log can export CSV format Field Name Explanation Door O...

Страница 44: ...s of brushing card feedback results 1 Temporary Card only added the card number without adding other rules 2 Valid Card added access rules 3 Illegal Card Did not add information 7 Function Key Key Event You might set up the key type with the Key Event Type Subtype Usage Key Event None No responding Dial Dialing function Release Delete password input cancel dialing input and end call OK identificat...

Страница 45: ...com In Intercom mode if the caller s IP phone supports Intercom feature the device can automatically answer the Intercom calls Multicast Multicast function is to deliver voice streams to configured multicast address all equipment monitored the multicast address can receive and play it Using multicast functionality would make deliver voice one to many which are in the multicast group simply and con...

Страница 46: ...dress and port When the device make a multicast all devices monitoring the address can receive the multicast data calling configuration If the device is in calls or it is three way conference or initiated multicast communication the device would not be able to launch a new multicast call 8 Alert Field Name Explanation Input settings Input Detect Enable or disable Input Detect ...

Страница 47: ...ng Input trigger When the input port meet to trigger condition the output port will trigger The Port level time change By Output Duration control Remote DTMF trigger By duration Received the terminal equipment to send the DTMF password if correct which triggers the corresponding output port The Port level time change By Output Duration control By Calling State During the call receive the terminal ...

Страница 48: ...quipment will be sent alarm to the corresponding server Reset command When the equipment receives the command of reset from server the equipment will stop alarm Reset Alerting Status Directly stop the alarm from equipment in the Webpage Ring Type Set the Ring Type ...

Страница 49: ... TX s Auto MDIX RJ 45 Camera 1 4 color CMOS 1 megapixel wide angle RFID IC card reader optional EM4100 125Khz Standard configuration MIFARE One 13 56Mhz Custom made Power supply mode 12V 1A DC or PoE PoE PoE 802 3af Class 3 6 49 12 95W Cables CAT5 or better Shell Material Cast aluminium panel Cast aluminium back shell Working temperature 40 C to 70 C Working humidity 10 95 Storage temperature 40 C...

Страница 50: ...ntegrated RFID Card reader 1 indoor switch interface 1 electric lock relay Anti tamper switch External power supply Door phone call password RFID card indoor switch Protection level IP65 IK10 CE FCC 3 Schematic diagram Lock status Call status Ring status Network and registration status Housing Speaker Numeric keypad password and dialing DSS key with LED MICs RFID area Camera Infrared light ...

Страница 51: ...d dial or phone number When set the speed dial key can press it to call direct The owner answers the call with pressing the key to unlock the door for visitors 2 Owner calls to visitors Owner calls to visitors via SIP phone SIP door phone answers the call automatically Owner use keypad to input corresponding Access codes to unlock the door Slot cards Use pre assigned RFID cards to unlock the door ...

Страница 52: ... Select the admin card of need to delete click Delete Add user cards Method 1 used to add cards for starters typically 1 In web page EGS Setting Card Reader Working Mode option select Card Issuing function 2 Click Apply Card Reader would be entered the issuing status 3 Use new card to touch card reader induction area and then you might hear the confirmed indication tone from the device Repeat step...

Страница 53: ...e new card to touch card reader induction area and you might hear the confirmed indication tone from the device Repeat step 2 to add more cards 3 Use Issuer admin card to touch card reader induction area again it would be back to normal working status Methods 3 use to add few cards 1 Input cards number in EGS Setting Add Access Rule ID page and then click Add Note you can also use the USB card rea...

Страница 54: ...e back to the Normal status Method 2 used to batch add cards for intermediates 1 Use Revocation admin card to touch card reader induction area and it would be entered revoking card status 2 Use the cards you want to delete from system to touch card reader induction area and you might hear the card reader confirmed indication tone Repeat step 2 to delete cards 3 Use Revocation admin card to touch c...

Отзывы: