PREPARATIONS BEFORE USE 

WINDING THE POWER CORD

1

Wind the power cord around 
the cord storage hooks.

Secure  the  power
cord plug on the 
power cord. 

Cord  Storage
Hooks

THERMAL SAFETY DEVICE IN MAIN BODY

To protect your vacuum cleaner motor from overheating, a thermal safety device has been 
built in. If your vacuum cleaner hose or air intake clogs up with dust or dirt, or if your dust 
bag becomes full and you continue to run the machine, the vacuum will shut off 
automatically to prevent the motor from overheating. If this happens, turn off slide  switch 
and disconnect your vacuum from power outlet, remove the material clogging the machine 
and let  your vacuum  cool down  for approximately 

45

 minutes.  You can  then restart  your 

vacuum cleaner and use it again.

RELEASING THE POWER CORD

1

2

Rotate the upper cord  
storage hook downward.

Return the hook to the 
upright position before 
attempting to rewind 
the power cord.

Upper Cord
Storage Hook

Содержание FM766HG

Страница 1: ...ATTACHMENTS EMPTYING THE DUST COMPARTMENT CLEANING THE FILTERS CLEARING BLOCKAGES IN THE SUCTION HOSE AND CLEANING THE AGITATOR ASSEMBLY REPLACEMENT INSTRUCTIONS TROUBLESHOOTING LIMITED WARRANTY Cont...

Страница 2: ...ay from heated surfaces 7 Do not unplug by pulling on the cord To unplug grasp the plug not the cord 8 Do not handle the plug or the vacuum cleaner with wet hands 9 Do not put any objects into the ope...

Страница 3: ...for household or commercial use Note to user concerning attachment plug Grounding Instructions This appliance must be grounded If it should malfunction or breakdown grounding provides a path of least...

Страница 4: ...t Compartment Carrying Handle DusterKnob ON OFF Switch Release Button A Release Button B Release Button C Suction Hose B Filter Cover Wand Handle Release Lever Power Cord Upholstery Tool Dusting Brush...

Страница 5: ...ction Hose A Caution Do not connect the power cord plug to the wall outlet until assembly is completed Attaching the handle PREPARATIONS BEFORE USE Attaching the suction hose A attachments 4 1 2 Set t...

Страница 6: ...r if your dust bag becomes full and you continue to run the machine the vacuum will shut off automatically to prevent the motor from overheating If this happens turn off slide switch and disconnect yo...

Страница 7: ...vacuum cleaner can be set to one of three positions Upright Normal Parallel Place your foot on handle release lever as shown and pull back on the handle until it releases from its upright position pos...

Страница 8: ...o the RUG position When cleaning a bare floor or when using one of the attachments set the RUG FLOOR TOOLS selector to the FLOOR position Caution Do not change the setting of the RUG FLOOR TOOLS selec...

Страница 9: ...ion Before using the attachments please make sure the hose is hooked on the holder mount When you have finished using the attachments replace them in their original positions as shown on page 4 Tabs G...

Страница 10: ...Hose Cuff Suction Inlet Suction Hose A USING THE ATTACHMENTS 9 Hose Attachment Line up notches push hose in till it clicks Handle...

Страница 11: ...r cord from the wall outlet before cleaning Empty the dust compartment when contents reach the MAX mark Press the release button A meanwhile press the release button B to remove the dust compartment P...

Страница 12: ...ith a hair dryer or by placing in a clothes dryer Hot air may cause the filters to warp Reattaching the filters Insert the main filter into the prefilter as shown 11 The main filter and prefilter will...

Страница 13: ...the agitator assembly clean the assembly Remove threads caught in the assembly by cutting them with scissors 12 Remove the bottom plate refer to page 15 Set the vacuum cleaner to the upright position...

Страница 14: ...When removing the headlight lamp be careful not to pull on the headlight lamp wiring 4 Remove the lamp by pushing it gently in the direction of the arrow and then turning it counterclockwise 5 Push a...

Страница 15: ...fer to page 15 Lift out the agitator assembly and then remove the flat belt from the motor shaft and the agitator pulley Place the agitator assembly into the grooves in the nozzle head making sure tha...

Страница 16: ...PLATE Insert the projection on the bottom plate into the groove on the nozzle housing and set the bottom plate in place 3 Turn the vacuum over and place in the upright position 2 2Using a Philips scre...

Страница 17: ...eplacement filters 16 REPLACEMENT INSTRUCTIONS REPLACING THE FILTER Caution Do not wash the sub filter in a washing machine and do not use any other equipment such as a hair dryer to dry it Always all...

Страница 18: ...et to the ON position Suction force is weak The agitator does not operate The power cord plug is not securely inserted into the wall outlet Insert the power cord plug securely into the wall outlet 17...

Страница 19: ...y unit that has been tampered with or used for commercial purposes This limited warranty does not cover damage caused by misuse abuse negligent handling or damage due to faulty packaging or mishandlin...

Отзывы: