DIN RAIL WIRED ACTUATOR FOR FAN COIL ROOM THERMOSTAT

CH176D

TECHNICAL FEATURES

Power supply and absorbed power

230Vac 50Hz - 2VA

BUS A/B input

Power thermostat data (default setting: SLAVE)

Relay output features

5(3)A 250V~

Voltage-free switching contacts with mains voltage

2 valve outputs (N-V1 and N-V2)

Mains voltage switching contacts

3 motor contact outputs (M1, M2 and M3)

0 ... 10V output

20 mA - 470Ω

Probe input

NTC 10 KΩ (Fantini EC15-EC18-EC19-EC20)

Protection rating

IP00

Software class

A

Maximum temperature 

T45

Degree of pollution

2

Complies with Standards

EN60730-1 and second parts

Micro-disconnection

1B

Impulse voltage

4000V

Assembly type and dimensions

6-module DIN Rail

Product not made in Italy

Содержание CH176D

Страница 1: ...ONS FOR USE FANTINI COSMI S p A Via dell Osio 6 20090 Caleppio di Settala Milan ITALY Tel 39 02 956821 Fax 39 02 95307006 info fantinicosmi it www fantinicosmi it DIN RAIL WIRED ACTUATOR FOR FAN COIL...

Страница 2: ...o a thermostat for fan coil CH133AR2 CH133RR CH130AR2 CH130ARR CH130RR via a bipolar cable allows to remotely control the two valves the three speed motor or a 0 10V motor and accept a temperature sen...

Страница 3: ...ntacts with mains voltage 2 valve outputs N V1 and N V2 Mains voltage switching contacts 3 motor contact outputs M1 M2 and M3 0 10V output 20 mA 470 Probe input NTC 10 K Fantini EC15 EC18 EC19 EC20 Pr...

Страница 4: ...NTENTS OF PACKAGE 2 TECHNICAL FEATURES 3 1 INSTALLATION 5 2 CONNECTING SEVERAL MODULES TO ONE THERMOSTAT 6 3 OPERATING MODE SELECTION COMPATIBILITY WITH ACTUATOR CH172D 6 4 LUMINOUS STATUS INDICATOR L...

Страница 5: ...ified personnel in compliance with the requirements concerning installation of electrical devices Make sure that the power network is disconnected before making any connections or working on the devic...

Страница 6: ...le set up as MASTER is the one read by the thermostat The connection between the various devices must be made as per the diagram in the following figure 3 OPERATING MODE SELECTION COMPATIBILITY WITH A...

Страница 7: ...LUMINOUS STATUS INDICATOR LED The CH176D unit is equipped with a status indicator made via a two coloured LED diode Flashing red the actuation module is configured as Master and is receiving a command...

Страница 8: ...FANTINI COSMI S p A Via dell Osio 6 20090 Caleppio di Settala Milan ITALY Tel 39 02 956821 Fax 39 02 95307006 info fantinicosmi it www fantinicosmi it 5679956 01 2021...

Отзывы: