background image

 

2.17.- Wheels for the vertical transport of the tower to it’s working location when folded. 

 

 
3.- Safety precautions. 

 

3.1.- Place the tower only on solid and levelled surfaces. 

 
3.2.- Verify that the legs are correctly inserted and fastened. 

 

3.3.- Verify that the tower is in a vertical position by means of the bubble level (F) 

placed in the base profil. Adjust, if necessary, with the plate support (Q), rotating the 

hand crank (H). 
 

3.4.- Verify the tower is in vertical position and is blocked in the working position by 

means of the safety catches (M1, M2, M3). 

3.5 Fix the adjustment handles while the profils are being lifting. 
 

3.6.- If you use the tower open air, you have to place it on a secure surface and protect 

the tower against the wind. 

 

3.7.- Do not use stairways neither over the tower nor leaned in it. 
 

3.8.- Be careful with cables, prominent objects, etc. placed above the tower. 

 

3.9.- Do not stay under the load. 

 
3.10.- Do not move the tower when it is lifted with load. 

 

3.11.- Before you use the tower the first time verify the cable, this must be  free of cuts 

and fraying. Do not use inappropriate cables. 
 

3.12.-  Never dismount the winch hand crank (W) if the tower is loaded. 

 

3.13 The minimum load required for a perfect braking function is 25 kg. The brake will 

not function without this minimum load. 
 

3.14.- Do not apply oil or grease to the winch brake mechanism. 

 

3.15.- Not approved to lift people. 
 

3.16.- For the transport, download all the sections and blockade them with their safety 

catches. 

 

 
4.- Operating. 

 

4.1.- In order to place the tower in their working position, put the tower on a hard and 

levelled surface. 

 
4.2.- Get on the legs (P) of their support for the transport (S) and insert them in their 

working lodging (V) verifying that they are tightly fastened by the safety catches (R). 

 

4.3.- Adjust the vertical position of the tower by means of the plate support (Q) rotating 
the hand crank (H) in the necessary direction to manage the bubble level (F) to the 

centre. 