APPLICATIONS INCLUDE:

• Indoor Pools

• Night Clubs

• Spa's

• Locker Room

• Health Centers

• High humidity Applications

POWER & WEIGHT

• Volts

120V

• Amperage

5.4 Amps Total

• Weight

80.3 Kg (177 Lbs)

• Shipping Weight

98 Kg (217 Lbs)

• Blowers (x2)

115V, 60 Hz, 2.7 Amps

• Phase

Single

SHR 8005R

Light Commercial HRV

The Fantech SHR8005R is
designed to provide an economi-
cal solution for high humidity
applications such as indoor
swimming pools, spas and fit-
ness facilities. The higher humid-
ity generation rate in these appli-
cations leads to annoying window
condensation, mold and struc-

ture deterioration. It’s designed to reduce the occurrence of
condensation in the indoor environment by first operating in
recirculation mode, moving air around the structures, sweeping
windows dry and eliminating troublesome cold spots, then
switching to air exchange mode as needed. Air exchange mode
simply exhausts humid air to the outside and replaces it with
drier air from outside. The airstreams are separated by an
energy efficient heat recovery core which uses the energy in the
exhaust air to lower the load on the HVAC system. Automatic
defrost and provisions for condensation are standard.

SPECIFICATIONS

CASE

20 gauge G90 galvanized steel coated with baked

powder paint, insulated with 25mm (1 inch) and 50mm (2
inch) on outdoor air side foil-faced high density polystyrene
foam for condensation control.

BLOWERS

Two (2) maintenance-free Ebm-Papst™ backward

inclined motorized impellers with permanently lubricated sealed
ball bearings and (TOP) thermal overload protected.

HEAT RECOVERY CORES 

The heat recovery cores are fixed plate

cross-flow heat exchanger using 1100 alloy aluminum and
capable of transferring sensible heat between air streams.
The heat recovery cores are engineered with a turbulence
inducing geometry in order to maximize heat transfer while
allowing an effective evacuation of condensate. The plates are
hemmed to avoid cross-contamination of airstreams.

FILTERS

The exhaust and fresh air streams are protected by

MERV1 washable filters constructed to meet UL Class2.
Optional MERV6 filters are direct replacement to the MERV1.
Use of MERV6 filters will add an additional system pressure
of 72 Pa (0.29in.wg) at 378 l/s (800cfm).

MOUNTING

Unit can be rod mounted or seated on a

platform. Flanged connections are provided for suitable
ductwork connections. Unit shall be adaptable for easy
service of electrical components.

CONTROLS

External three (3) position (Low/Standby/Medium)

rocker switch that will offer continuous ventilation. Compatible
with all Fantech HRV controls.

FROST CONTROL

During the defrost sequence, a motorized

damper temporarily blocks the incoming fresh air stream so
that the warm air from the building can circulate through the
HRV. The exhaust blower shuts down and the supply blower
switches into high speed to maximize the effectiveness of the
defrost strategy.

SERVICEABILITY

Unit has hinged or screwed access panels on

front and back. Cores, filters, motors and drain pan are
serviceable from either sides of the unit. Fan assemblies are
mounted on a removable sliding base. Heat recovery cores are
mounted in slide-out rails for ease of inspection, removal and
cleaning. Accessibility to the electrical box is maintained for
any unit installation.

0

50

100
150
200
250
275
300
350
400
450
500
550
600
650
700
750
800
850
900
950

2007-10-01

Thermal Effectiveness

10%

30%

50%

70%

90%

0

400

800

1200

Airflow (cfm)

Effectiveness

0

189

378

566

Airflow (l/s)

0

50

100
150
200
250
275
300
350
400
450
500
550
600
650
700
750
800
850
900
950

2007-10-01

Airflow Performance

0.0

0.4

0.8

1.2

1.6

0

400

800

1200

Airflow (cfm)

External Static Pressure, (in wg)

0

99

199

298

0

189

378

566

Airflow (l/s)

External Static Pressure (Pa)

High
Medium
Low
Recirculation

Airflow Performance

Airflow (l/s)

Airflow (cfm)

Airflow (cfm)

E

xt

e

rn

a

S

ta

ti

P

re

s

s

u

re

(i

n

 w

g

)

E

xt

e

rn

a

S

ta

ti

P

re

s

s

u

re

 (

P

a

)

Thermal Effectiveness

Airflow (l/s)

E

ff

e

ct

iv

e

n

e

s

s

Содержание SHR 14105R

Страница 1: ...er operating at a higher static After installation the compatibility of the two pieces of equipment must be con firmed by measuring the airflow s of the Heat Recovery Ventilators It is always importan...

Страница 2: ......

Страница 3: ...evacuation of condensate The plates are hemmed to avoid cross contamination of airstreams FILTERS The exhaust and fresh air streams are protected by MERV1 washable filters constructed to meet UL Clas...

Страница 4: ...he unit has access doors on the front and back Also the main control panel may be moved from front to back allowing for ducting layout Outdoor or Recirculated Air Indoor Air Standard Configuration as...

Страница 5: ...LTERS The exhaust and fresh air streams are protected by MERV1 washable filters constructed to meet UL Class2 Optional MERV6 filters are direct replacement to the MERV1 Use of MERV6 filters will add a...

Страница 6: ...ont or the back of the cabinet 63mm 2 5 PORT CONFIGURATION The unit has access doors on the front and back Also the main control panel may be moved from front to back allowing for ducting layout Stale...

Страница 7: ...MODES OF OPERATION Intermittent operation can be obtained by toggling the switch located on outside of cabinet External low voltage contacts allow for high speed operation when an optional remote con...

Страница 8: ...ming required service maintenance Care must be taken to locate the recirculation port in an area that will not cause any unwanted contaminant to be drawn into the liv ing space during recirculation an...

Страница 9: ...nual INSTALLING DUCTS TO FROM INSIDE Direct Connection to Furnace Air handler return duct Should you wish to hard duct the supply air directly into the cold air return of the HVAC systems remember to...

Страница 10: ...eviation of 10 or less is acceptable AIR FLOW BALANCING A Pitot tube and gauge Note A professional air balancer should be contacted to commission the system properly A skilled HVAC Tech may complete t...

Страница 11: ...or light coil solution d Install clean cores making sure the matting sur faces have one sealing edges between each cores to minimize leaks e Install the clean filters f Replace access door Note Core i...

Страница 12: ...D WHITE BLACK WHITE UNI CTRL JUMPER SETTINGS OFF ON ON OFF ON OFF ON J4 J6 J5 J7 J1 J2 J3 GROUND N WHITE L BLACK FUSE SPECIFICATION FAH0800 HCE PCB REPLACEMENT FAH0900 FAH1400 FAH1200 TYPE FUSE RATING...

Отзывы: