Planning the Installation

Choosing the right remote mount blower (see page 7)

Look on page 7 for a list of Fantech fans recommended for use with the SHL & SGHL. Series Range Hood Liners. Some models remotely mount in 
the attic. Other models are used when installation requires a roof mount or wall mount fan.

1. To reduce the risk of fire and to properly exhaust air, the liner must 

be exhausted to the outside. Never exhaust into a wall, an attic or a 
concealed area in the building. This can create a potential hazard.

2. Consult a licensed ventilation contractor or qualified technician for 

proper installation of exhaust ducting. 

3. Locate the cooking area for minimum cross drafts – away from doors 

and windows, when possible.

4. Ducts must be of adequate size and duct runs should be as short as 

possible. Where turns are necessary, keep turning radius as large and 
as smooth as possible.

5. The ducting must be air tight. Use a minimum of 2 sheet metal screws 

at every duct joint. Then, seal the duct joints with high quality duct 
tape.

6. Only use ductwork constructed of materials deemed acceptable by 

state, municipal and local codes.

WARNINGS: Following Are Manufacturer’s Suggestions. Always Observe 
Local Building Codes.

• 

Liners installed in custom canopies constructed of combustible 
materials, should be installed with the combustible material structure 
a minimum of 36” above the surface of the heating element.

• 

Liners installed in custom canopies constructed of non-combustible 
materials, should be installed with the non-combustible material 
structure a minimum of 30” above the surface of the heating element.

• 

Follow all instructions regarding minimum safe clearances and 
installation location. Failure to do so may result in a safety hazard or 
fire.

• 

To reduce the risk of fire use only metal ductwork.

•  The hood liner is designed to install inside a custom hood enclosure 

and operates with a remote mount blower (purchased separately). See 
dimensional drawings (page 3) for hood dimensions. See chart (page 7) 
for Fantech exhaust fans recommended for use with these units.

•  A qualified person must complete the installation of this appliance. 

•  Plan the installation so that all minimum clearance are met or  

exceeded.

•  IMPORTANT: You must provide support framing and backing in the  

areas in which you are securing the liner to in your custom canopy. 
Failure to do so could damage the liner and void the warranty.

• 

The hood liner uses 120VAC, 60 Hz power. Supply wires should be 
installed by a qualified person(s) and must meet all electrical codes. 
The SGHL30 Hood Liner has 6” is desgined for use with 8” duct 
connections, SGHL36 is designed for use with 8” diameter duct, the 
SHL36 is designed for use with 8” diameter duct and the SHL42 & 
SHL48 is designed for use with 10” diameter duct. Use only rigid metal 
duct.

• 

For a truly quiet kitchen ventilation system add a Fantech “duct 
silencer” (LD Series) to the installation. The simple addition of an inline 
duct silencer between the hood liner and the remote fan can typically 
reduce the “perceived” sound level of the system by more than 50%. 
For more information visit www.fantech.net.

• 

A quality cap with built in backdraft damper or an inline damper is 
recommended to minimize cold air return through the duct when the 
product is not in use.

• 

Always install ventilation products with an approved wall or roof cap.

• 

Duct performance is improved by using round, smooth metal duct work 
instead of rectangular.

• 

If multiple elbows must be used, ensure that there is a minimum of 24” 
of straight duct between any two elbows.

• 

Avoid ”S:” or back to back configurations caused by adjacent elbows.

• 

Route ducting to terminate at the hood liner.

Содержание SHL36

Страница 1: ...032 Rev Date 121313 United States 10048 Industrial Blvd Lenexa KS 66215 Tel 800 747 1762 Fax 800 487 9915 Canada 50 Kanalflakt Way Bouctouche NB E4S 3M5 Tel 800 565 3548 Fax 877 747 8116 SHL SGHL Mode...

Страница 2: ...for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Building codes require Makeup air for any hood system exhausting over 400 cfm When cutting or drilling i...

Страница 3: ...ters Speed Light Controls Wiring Location SGHL 30 SGHL 36 Dimensions 7 8 22 23mm 2 25 57 15mm SGHL30 F 15 381mm SGHL36 F 18 457 2mm Front of hood F A B C E Duct 1 25 4mm Dimmable Halogen Lights Washab...

Страница 4: ...in a safety hazard or fire To reduce the risk of fire use only metal ductwork The hood liner is designed to install inside a custom hood enclosure and operates with a remote mount blower purchased se...

Страница 5: ...e for recommendations 5 The Fantech liner has been designed to accommodate several differ ent motor speed controls for example ThermadorTM model CTR3 Q Always consult the manufacturer s installation i...

Страница 6: ...ning should be adjusted according to the type and amount of cooking Best results will be achieved by cleaning soiled components as soon as pos sible 2 Filters must be cleaned regularly SHL Series Remo...

Страница 7: ...interior inline 910 780 FKD 10XL interior inline 1266 1060 FKD 12XL interior inline 2016 1460 RE 10XL exterior roof wall 753 720 SGHL30 Model Location Mounting Airflow at 0 Typical Airflow FG 6 interi...

Страница 8: ...tion for any breach of warranty WARRANTY VALIDATION The user must keep a copy of the bill of sale to verify purchase date These warranties give you specific legal rights and are subject to an applicab...

Страница 9: ...9 fantech Notes...

Страница 10: ...10 fantech Notes...

Страница 11: ...11 fantech Notes...

Страница 12: ...fantech Fantech reserves the right to make technical changes For updated documentation please refer to www fantech net Fantech...

Отзывы: