Fantech RE(C) 54 Скачать руководство пользователя страница 2

2

Note

Warning / 

Important 

note

Information

Technical 

information

Practical tip

WARNINGS

DO NOT CONNECT POWER SUPPLY until fan is completely installed. Make 

sure electrical service to the fan is in the locked “OFF” position.

1. All units are suitable for use with solid-state speed control.

2. WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 

INJURY TO PERSONS – OBSERVE THE FOLLOWING:

a. Use this unit only in the manner intended by the manufacturer. If 

you have any questions, contact your manufacturer's 
representative.

b. CAUTION: Before installation, servicing or cleaning unit, switch 

power off at service panel and lock the service disconnecting 
means to prevent power from being switched on accidentally. When 
the service disconnecting means cannot be locked, securely fasten 
a prominent warning device, such as a tag, to the service panel.

c. Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 
including fire-rated construction.

d. Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to 
prevent back drafting. Follow the heating equipment manufacturer’s 
guideline and safety standards such as those published by the 
National Fire Association (NFPA), and the American Society of 
Heating Refrigeration and Air Conditioning Engineers (ASHRAE), 
and the local code authorities.

e. When cutting or drilling into wall and ceiling, do not damage 

electrical wiring and other hidden utilities.

f. Ducted fans must always be vented to the outdoors.

g. If this unit is to be installed over a tub or shower, it must be 

marked as appropriate for the application and be connected to a 
GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.

h. NEVER place a switch where it can be reached from a tub or 

shower.

3. WARNING! Check voltage at the fan to see if it corresponds to the 

motor name plate.

1. The compactness and adaptability of Models RE(C) fans permit easy 

installation. The straight-thru air flow fans are shipped fully 
assembled and can be mounted at any angle. For various mounting 
and ducting options. (see 

Typical Installations

)

2. Because this unit has rotating parts, safety precautions should be 

exercised during the installation, operation, and maintenance phase.

3.

 CAUTION:

 “For General Ventilation Use Only. Do Not Use To Exhaust 

Hazardous Or Explosive Material and Vapors.”

4. Remove unit from package and inspect within 15 days after receipt. 

If damaged, report damage to carrier. Do Not operate this unit with 
visible damage to the blower or impeller assembly.

5. Ensure centrifugal impeller has free rotation. If impeller hits orifice, 

check screws holding motor bracket. Adjustment can be made by 
loosening motor bracket screws, then pull up on motor bracket while 
tightening screws. Tighten all screws before operating unit. 

WEAR HAND PROTECTION AND STAY CLEAR OF SHARP EDGES.

6. Screen guards must be installed when fan will be within reach of 

personnel, within (7) feet of the working area, or when advisable for 
safety.

Содержание RE(C) 54

Страница 1: ... E4S 3M5 Tel 800 565 3548 Fax 877 747 8116 RE C Series Exterior Roof Wall Centrifugal Fans Fantech Inc certifies that the RE C Series shown herein is licensed to bear the AMCA Seal The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program ...

Страница 2: ...ting or drilling into wall and ceiling do not damage electrical wiring and other hidden utilities f Ducted fans must always be vented to the outdoors g If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit h NEVER place a switch where it can be reached from a tub...

Страница 3: ...Amps RE C 54 10 15 16 6 5 15 1 2 2 3 4 6 11 16 3040 19 0 18 RE C 6 13 15 16 6 1 4 6 15 1 2 3 9 16 2 1 2 2700 87 0 80 RE C 8XL 16 9 16 5 15 16 8 20 6 9 16 2 15 16 2800 153 1 40 RE C 10XL 20 13 16 11 1 2 10 20 3 3 3250 394 3 60 RE C 10XLT 20 13 16 12 11 16 10 20 3 3 2950 531 4 86 All demensions in inches H dimensions is 1 1 2 on model REC only Optional 4 reducer for dimension C B A C D D D X Y ...

Страница 4: ...ong the top edge of the curb 4 Place unit on curb and securely attach with bolts or screws 5 Through the opening attach ductwork to fan inlet orifice by using Fantech FC clamps or duct tape 6 Refer to wiring diagram in this guide to complete electrical connections 7 Once secured and wired generously apply tar or other sealant around edges of base to prevent leakage Be sure to replace any lifted sh...

Страница 5: ...tion for any breach of warranty WARRANTY VALIDATION The user must keep a copy of the bill of sale to verify purchase date These warranties give you specific legal rights and are subject to an applicable consumer protection legislation You may have additional rights which vary from state to state This warranty does not apply to any Fantech product or part which has failed as a result of faulty inst...

Страница 6: ...6 Notes ...

Страница 7: ...7 Notes ...

Страница 8: ...Fantech reserves the right to make technical changes For updated documentation please refer to www fantech net Fantech ...

Отзывы: