WARNINGS
DO NOT CONNECT POWER SUPPLY until fan is completely installed. Make
sure electrical service to the fan is in the locked “OFF” position.
1. All units are suitable for use with solid-state speed control.
2. WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS – OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer. If
you have any questions, contact your manufacturer's
representative.
b. CAUTION: Before installation, servicing or cleaning unit, switch
power off at service panel and lock the service disconnecting
means to prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service panel.
c. Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction.
d. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Association (NFPA), and the American Society of
Heating Refrigeration and Air Conditioning Engineers (ASHRAE),
and the local code authorities.
e. When cutting or drilling into wall and ceiling, do not damage
electrical wiring and other hidden utilities.
f. Ducted fans must always be vented to the outdoors.
g. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
h. NEVER place a switch where it can be reached from a tub or
shower.
3. WARNING! Check voltage at the fan to see if it corresponds to the
motor name plate.
1. The compactness and adaptability of Models RE(C) fans permit easy
installation. The straight-thru air flow fans are shipped fully
assembled and can be mounted at any angle. For various mounting
and ducting options. (see
Typical Installations
)
2. Because this unit has rotating parts, safety precautions should be
exercised during the installation, operation, and maintenance phase.
3.
CAUTION:
“For General Ventilation Use Only. Do Not Use To Exhaust
Hazardous Or Explosive Material and Vapors.”
4. Remove unit from package and inspect within 15 days after receipt.
If damaged, report damage to carrier. Do Not operate this unit with
visible damage to the blower or impeller assembly.
5. Ensure centrifugal impeller has free rotation. If impeller hits orifice,
check screws holding motor bracket. Adjustment can be made by
loosening motor bracket screws, then pull up on motor bracket while
tightening screws. Tighten all screws before operating unit.
WEAR HAND PROTECTION AND STAY CLEAR OF SHARP EDGES.
6. Screen guards must be installed when fan will be within reach of
personnel, within (7) feet of the working area, or when advisable for
safety.