background image

FRD Installation Manual

3

Motor

Leads

Black

Blue

Capacitor

(Ground)

L (Black)

N (White)

Supply

Voltage

Brown

Green/Yellow (     )

Motor

Leads

Black

Blue

Capacitor

(Ground)

L (Black)

N (White)

Supply

Voltage

Brown

Green/Yellow (     )

Model

A

B

C

D

E

F

G

H

J

Weight

FRD 12-6

5⁷₈

6³₄

7⁵₈

11⁷₈

12³₄

13⁵₈

15³₄

11

1³₄

18

FRD 16-8

7³₄

8³₄

9³₈

15³₄

16¹₂

17³₈

19³₄

15

1³₄

23

FRD 16-8XL

7³₄

8³₄

9³₈

15³₄

16¹₂

17³₈

19³₄

15

1³₄

29

FRD 20-10

9³₄

10⁵₈

11³₈

19⁵₈

20¹₂

21³₈

20³₈

18

1³₄

41

FRD 24-14

13³₄

14⁵₈

15³₈

23⁵₈

24³⁄₈

25¹⁄₄

28¹⁄₂

20

62

Dimensions

A

B

C

D

E

F

H

G

J

Dimensional Data

Wiring

FRD 12-6, FRD 16-8, FRD 16-8XL & FRD 20-10

FRD 24-14

Notes:

1. All leads are color coded.
2. Capacitor leads may be reversed. Fan operation will not be affected.

All dimensions in inches, Weight in pounds.

Содержание FRD Series

Страница 1: ... installation servicing or cleaning unit switch power off at service panel and lock the service disconnect ing means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as tag to the service panel c Installation work and electrical wiring must be done by qualified person s in accordance with all ...

Страница 2: ... is secure temporary fixture can be removed 6 Make duct connections Flexible connectors supplied by others are recommended 7 Make electrical connections according to the appropriate diagram on the next page Please follow all applicable codes when installing this unit 1 Determine the fan location and preferred mounting method 2 If needed install the included mounting bracket on fan Be sure to use a...

Страница 3: ...ight FRD 12 6 5 6 7 11 12 13 15 11 1 18 FRD 16 8 7 8 9 15 16 17 19 15 1 23 FRD 16 8XL 7 8 9 15 16 17 19 15 1 29 FRD 20 10 9 10 11 19 20 21 20 18 1 41 FRD 24 14 13 14 15 23 24 25 28 20 62 Dimensions A B C D E F H G J Dimensional Data Wiring FRD 12 6 FRD 16 8 FRD 16 8XL FRD 20 10 FRD 24 14 Notes 1 All leads are color coded 2 Capacitor leads may be reversed Fan operation will not be affected All dime...

Страница 4: ...ou must 1 Have a return materials authorization RMA number This number may be obtained by calling FANTECH INC At 1 800 747 1762 Please have bill of sale available 2 The RMA number must be clearly displayed on the outside of the carton or delivery will be refused 3 All product being returned must be shipped prepaid and be accompanied with a copy of the bill of sale 4 Product will be replaced repair...

Отзывы: