background image

3

fantech

Industrial Dehumidifier

Electrical Requirements

For 115V operation, a common grounded outlet on a 15 amp circuit is required. If used in a wet area, a ground fault interrupter (GFI) is required.

Built in Electrical Safety

For your safety and protection this appliance is manufactured with a grounded plug on its power cord. The power cord  must be plugged into a properly 
grounded receptacle. If a grounded receptacle does not exist, have one installed by a certified electrician. Do not cut or remove the grounding prong 
on the power cord plug if equipped. We recommend that this electrical circuit/receptacle operate under a separate breaker or fuse.

If an extension cord is required, it must have a minimum of 14 gauge conductors if 25 feet long or less and 12 gauge conductors if greater than 25 
feet long.

Limitations of Use

Temperature: 4°C to 35°C (40°F to 95°F)
Relative Humidity: 20 to 80%

Water Removal

The dehumidifier is equipped with an internal condensate pump to remove the water that is collected from the air. This allows the water to be pumped 
20 feet with the attached hose. If the water needs to be pumped more than 20 feet above the unit, a second pump must be added to relay the water. 
The condensate pump automatically purges for 20 seconds every four minutes.

Figure 1

Place dehumidifier inside area to be dried. Make sure all windows and doors are closed to the 
outside and seal off the wet area from any unaffected areas. Route condensate hose into a drain, or 
a very large container. 

OFF Mode

The unit is OFF but plugged in a 120V AC power source. The back light of the display panel in on. 
See figure 1.

Start-up Mode

The dehumidifier is turned on by pressing the power button (figure 2). When the dehumidifier is 
started, the display will briefly show the software version # and the unit status (figure 3), followed 
by a 55 second countdown and unit status (figure 4) then the cumulative hours and unit status 
(figure 5).

Pressing the power button during the first minute will cause the unit to go into OFF Mode 
immediately. Display will show "unit off" (figure 1).

Normal Run Mode

During Normal Run Mode the compressor is running causing the evaporator to get cold resulting in 
condensate forming on the coil. 

The unit will stay in normal run mode for variable length of time depending on the ambient conditions. 

Pressing the power button (figure 1) will send the unit in shut down mode (Figure 6)

Defrost Mode

During the defrost mode, the display show that the unit is in defrost mode (figure 7). Defrost will activate 
when the evaporator coil surface temperature goes below -2oC. The compressor will shut off and remain 
off until the coil surface temperature reaches 10oC of or 15 minutes have elapse (which ever occurs first).

Long defrost mode

Heavy frosting on the coil can be expected during low ambient conditions and will not affect the 
operation of the unit. 

Figure 2

Operation

Unit off

Figure 3

Version 4.11

Compressor Delay

Figure 4

00:54

Compressor Delay

Figure 5

Run Hrs 1332.1

Normal Run

Figure 7

Defrost

Figure 6

14:59

Shutting Down

Figure 8

Long Defrost

Содержание EPD Series

Страница 1: ...che NB E4S 3M5 Tel 800 565 3548 Fax 877 747 8116 EPD Series Industrial Dehumidifier Deshumidificador industrial Industrial Dehumidifier Déshumidificateur industriel Deshumidificador industrial Operating Instructions Guide d utilisation Instrucciones de uso Read and Save These Instructions Lisez et conservez ces instructions Lea y guarde estas instrucciones 1 3 5 405037 Fantech Ltd 1 800 565 3548 E...

Страница 2: ...cte a un contacto de pared de conexión a tierra de 3 terminales No quite la terminal de conexión a tierra No use un adaptador No use un cable elétrico de extensión No seguir estas instrucciones puede ocasional la muerte incendio o choque eléctrico ADVERTENCIA El deshumidificador utiliza un sistema de líquido refriger ante de alta presión y un circuito eléctrico de alto voltaje que podrían resultar...

Страница 3: ...cted areas Route condensate hose into a drain or a very large container OFF Mode The unit is OFF but plugged in a 120V AC power source The back light of the display panel in on See figure 1 Start up Mode The dehumidifier is turned on by pressing the power button figure 2 When the dehumidifier is started the display will briefly show the software version and the unit status figure 3 followed by a 5...

Страница 4: ...humidifier cabinet figure 12 Reverse procedure to re install the filter into the dehumidifier Metal filters should be washed with soap and water and paper filters should be replaced Paper filter size is a nominal 12 x 12 x 1 Operating the unit without the filter in place will cause reduced efficiency due to dirty coils and increase the frequency of internal coil cleaning Stacking The dehumidifiers...

Отзывы: