Fanmaster Ouber PAC500 Скачать руководство пользователя страница 3

 1. Safety Notice

1. Do not put unnecessary things/objects into the air outlet as this will cause 
damage to the fan and could lead to injury.

2. Do not climb up or stack things on the unit. Do not let children or infrm 
persons near or operate the fan. 

3. Do not place burning apparatus near the fan as it may cause carbon monox-
ide poisoning. Precautions must be taken to avoid the back-fow of gases into 
the open fue of gas or other fuel-burning appliances.

4. Do no attempt to make any modifcations to or repair the product yourself. 
Have it installed or repaired by a qualifed person only.

5. Do not place the unit where there is fammable and explosive gas.

6. If this machine will be not used for a long period of time, turn off the water 
supply and drain all the water out of the water tank and then run the fan func-
tion only to completely dry the cooling pads.

6. This unit must have a reliable earth wire connection. If the earth wire is 
incorrectly connected it could cause an electric shock or 

PORTABLE 

fre.

EVAPORATIVE AIR COOLER

1.

 15. Troubleshoot

Failure

phenomenon

Possible causes

Solution

Unable to turn on

1. No Power connection
2. Switch failure
3. Phase failure
4. Low voltage

1. Check power supply
2. Replace switch
3. Check phase
4. Check voltage

Excessive noise

1.  Fan  blade  dirty,  deformed  or 
damaged
2. Motor wear
3. There are sundries blocking the 
outlet

1.  Change  fan  blade  or  adjust 
bracket
2. Replace motor
3. Clear the sundries

Fuse burnt out

1. Water pump damage
2. Synchronous motor damage

1. Replace water pump
2. Replace synchronous motor

Water leakage

1. Machine on an unbalanced 
surface
2. Leaking from the tank
3. Drainage valve damage
4. Water inlet damage
5. Water level is too high
6. Water distribution system is 
damaged
7. Cooling pads are dirty

1. Move the machine to an even 
surface
2. Repair or replace tank
3. Replace drainage valve
4. Replace the water inlet
5. Adjust the foat valve
6. Check or replace the warter 
distribution system
7. Clean the cooling pads

No air supply

1. Cooling pad or flter is blocked
2. Control panel is damaged
3. Mainboard is damaged
4. Fan button doesnt work
5. Motor phase

1. Clean or replace the cooling pad 
and flter
2. Replace the control panel
3. Replace the circuit board
4. Check the motor
5. Check the phase

No cooling

1. Shortage of water

2. Water level system failure
3. Water pump damaged
4. Cool button doesnt work
5. Mainboard is damaged

1. Check water levels, add water 
to tank
2. Replace water level sensor
3. Replace water pump
4. Replace control panel
5. Replace circuit board

Water tank and 
flter screen with 
preceipitation

1. High control mineral in water 
supply

1. Increase draingage 

PORTABLE 

frequecny

EVAPORATIVE AIR COOLER

1

2

.

Содержание Ouber PAC500

Страница 1: ...RTABLE EVAPORATIVE AIR COOLER INSTRUCTION MANUAL MODEL NO PAC500 NewTech Coolers by Fanmaster We reserve all rights of this manual We reserve the right to change or modify this manual without prior notice ...

Страница 2: ...ed service or repair T o make a claim under the warranty take the product with proof of purchase to the store where you purchased the product or contact Fanmaster Pty Ltd Fanmaster Pty Ltd will pay your reasonable direct expenses of claiming under this warranty You may submit details and proof of your expense claim to Fanmaster Pty Ltd for consideration This warranty is given by Fanmaster Pty Ltd ...

Страница 3: ...4 Check voltage Excessive noise 1 Fan blade dirty deformed or damaged 2 Motor wear 3 There are sundries blocking the outlet 1 Change fan blade or adjust bracket 2 Replace motor 3 Clear the sundries Fuse burnt out 1 Water pump damage 2 Synchronous motor damage 1 Replace water pump 2 Replace synchronous motor Water leakage 1 Machine on an unbalanced surface 2 Leaking from the tank 3 Drainage valve d...

Страница 4: ... motor and the water pump both of which can be repaired at low cost and often by a mechanically inclined homeowner 4 V entilation air The constant and high volumetric fow rate of air through the building reduces the age of air in the building dramatically Evaporative cooling increases humidity In dry climates this may improve comfort and decrease static electricity problems The pad itself acts as ...

Страница 5: ...nd cool ing pads moving the machine or when not in use long periods May result in an electric shock or damage Use 0 15 0 6MPa water pressure Temperature cannot exceed 45 C banned May result in the cooling pad to dissolve and plastic product deformation damage and affect the performance Do not damage destroy over bend and twist the power cord Please do not place heavy objects on the power cord Agei...

Страница 6: ...ed by the manufacturer its service agent or similary by a qualifed persons in order to avoid a hazard 4 PORTABLE EVAPORATIVE AIR COOLER 12 Operating instruction 1 Make sure the voltage is in accordance with the local voltage before use 2 Connect the plug into the power source the machine will be in standby mode Press the ON OFF button to turn on and off Once turned off the machine will be in stand...

Страница 7: ...LER assistance from an engineering design 5 Environment of use 1 Ambient temperature 25 C 45 C 2 Environment relative humidity 90 3 Water supply should make softening treatment 0 C temperature of water supply 45 C Pressure of water supply 0 15 0 6MPa 4 Deviation of voltage can not be more than 10 of rated voltage 5 No corrosive gases 6 No infammable and explosive gas or dust 6 Packing list Number ...

Страница 8: ...et weight 46KG Applicable area m2 30 60 Air outlet dimension mm 160x690 Noise 70dB Water consumption 3 10L H Machine IP IPX4 7 Specifcations PORTABLE EVAPORATIVE AIR COOLER 8 Wiring diagram 6 PORTABLE EVAPORATIVE AIR COOLER 9 Brief diagram of structure 10 Parts list LCD Control Panel Fan Motor 0 55KW Water Sumbersible Pump Synchronous motor Water Float Filter screen black Cooling Pad Water Level S...

Отзывы: