Fanimation Vetricco FP3120 Series Скачать руководство пользователя страница 6

6

How to Hang Your Ceiling Fan

Figure 1

Floor

Ceiling

No

less than

7 ft

WARNING

To avoid possible electrical shock, be sure electricity is 

turned off at the main fuse box before hanging.

NOTE: If you are not sure if the outlet box is grounded, 

contact a licensed electrician for advice, as it must be 

grounded for safe operation.

WARNING

The fan must be hung with at least 7´ of clearance from 

floor to blades (Figure 1)

WARNING

The outlet box must be securely anchored and capable 

of withstanding a load of at least 50 lbs.  Hanger bracket 

must seat 

fi

 rmly against outlet box.  If the outlet box is 

recessed, remove wallboard until bracket contacts box.  

If bracket and/or outlet box are not securely attached, 

the fan could wobble or fall.

CAUTION

Do not connect fan blades until the fan is completely 

installed.  Hanging fan with blades connected may result 

in damage to the fan blades.

WARNING

Failure to seat tab in groove could cause damage to 

electrical wires and possible shock or fire hazard.

WARNING

To avoid possible shock, do not pinch wires between the 

downrod/hanger ball assembly and the hanger bracket.

Ceiling Joist

Wood  Member

(2

˝

 x 4

˝

 Approx.)

Figure 2

Junction 

Box

Ceiling

Support

Cable

Hanger Bracket

Ceiling

Figure 3

Downrod/Hanger

Ball Assembly

Attach

Safety Cable to

Ceiling Support

Cable

Tab

NOTE: 

Supply wires and

fan wires omitted for clarity

1.

  Using the 

3

8

˝

 x 2

˝

 lag bolt and flat washer, attach 

safety cable to ceiling joist or wood structural member. 

The lag bolt will pass through the flat washer, safety 

cable loop, the junction box and into the building structure 

(Figure 2). You will first drill a ¼

˝

 pilot hole into the 

building structure to prevent splitting or cracking.

2.

  Securely attach the hanger bracket to ceiling junction 

box 

acceptable for ceiling support

NOTE:

 

 Ceiling support cable must be fastened between 

flat washer and ceiling junction box (Figure 2).

3.

  Make sure the electrical supply wires, including the 

hanger bracket grounding wire and safety cable are 

pulled through the downrod, between the hanger bracket 

and the junction box so that electrical connections can be 

made later. 

4.

  Carefully lift the fan and seat the downrod/hanger ball 

assembly on the hanger bracket that was just attached to 

the ceiling joist.  Be sure the groove in the ball is lined up 

with tab on the hanger bracket. (Figure 3)

5.

  Attach the safety cable to ceiling support cable. Slide 

cable clamp onto safety cable (from fan). Place the end 

of cable through the loop of ceiling support cable. Pull as 

much cable through loop as possible. Feed end of cable 

into clamp hole and firmly tighten screw (Figure 3).  Cut 

off excess safety cable.

Содержание Vetricco FP3120 Series

Страница 1: ...D AND SAVE THESE INSTRUCTIONS Model No FP3120 The Vetricco Ceiling Fan VETRICCO Fan Satin Nickel Finish shown with Plastic Blade Set VETRICCO Fan Glossy Black Finish shown with Plastic Blade Set Net Weight 17 1 kg 38 lbs ...

Страница 2: ... on implied warranties Fanimation will not be liable for incidental consequential or special damages arising out of or in conjunction with product use or performance except as may otherwise be accorded by law This warranty gives you special legal rights and you may also have other rights that vary from state to state 10 A certain amount of wobble is normal and should not be considered a problem or...

Страница 3: ...nlight Socket Plate Assembly Lower Glass Housing Cover Hardware Bags Fan Motor Housing Assembly Downrod Hanger Ball Assembly Hanger Bracket One Phillips head screwdriver One stepladder One blade screwdriver One wire stripper Three wire connectors supplied Ceiling Canopy Adapter Plate Plastic Blades C26 Remote Control Hardware bag Seven 20 x 14mm blade holder to fan motor hub screws Thirteen 3 16 2...

Страница 4: ... four wires Route the wires and support cable through the Downrod If your fan is to replace an existing light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician WARNING ...

Страница 5: ...pin Securely tighten the setscrew in the Hanger Ball A loose setscrew could create fan wobble 7 While pulling up on the hanger ball securely tighten the two 3 16 24 x 13mm setscrews in the downrod support Figure 3 NOTE The setscrews must be properly installed as described above or fan wobble could result 8 Slide the Motor Coupling Cover down until it touches the top of the Housing Figure 4 5 Insta...

Страница 6: ... Figure 3 Downrod Hanger Ball Assembly Attach Safety Cable to Ceiling Support Cable Tab NOTE Supply wires and fan wires omitted for clarity 1 Using the 3 8 x 2 lag bolt and flat washer attach safety cable to ceiling joist or wood structural member The lag bolt will pass through the flat washer safety cable loop the junction box and into the building structure Figure 2 You will first drill a pilot ...

Страница 7: ...Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until the blades is in place Noise and fan damage could result ORANGE FOR UP LIGHT 1 Setting the Code The remote unit has 16 different code combinations To prevent possible interference from or to other remote units such as garage door o...

Страница 8: ...t serve as guides for easier installation 2 Securely attach the Canopy Housing to the Hanger Bracket using the external lockwashers and knurled knobs supplied with your fan Figure 1b Figure 1a Figure 1b NOTE Supply wires and fan wires omitted for clarity NOTE This step is applicable after the neccessary wiring is completed see page 7 Screw 2 per blade holder Figure 1 Blade Holder WARNING To avoid ...

Страница 9: ...remove one screw from support flange Figure 1 Figure 2 Figure 3 2 Be sure to square or line up the corners of the Adapter Plate with the corners of the motor housing Securely attach the Adapter Plate to the motor shaft by tightening the screws Figure 2 CAUTION To avoid possible electrical shock be sure electricity is turned off before installing downlight assembly ...

Страница 10: ...the Downlight Socket Plate Assembly Figure 5 6 Securely attach Lower Glass by tightening Final Glass Fasteners 4 supplied with the fan Don t overtighten Figure 6 7 You have now completed the assembly of your ceiling fan Restore electrical power INSTALLATION NOTE Be sure to line up the curved slotted holes located on both Lower Housing Support Plates Figures 4 5 Purpose of these holes are for the c...

Страница 11: ...rasive cleaning agents are not required and should be avoided to prevent damage to finish Periodic light dusting of the Plastic blades is recommended A feather duster will work best Avoid using water cleansers or harsh rags which can warp and ruin the finish CAUTION Do not use water when cleaning your ceiling fan It could damage the motor or the finish and create the possibility of electrical shoc...

Страница 12: ...ion Set of 3 AP32225CH 11 Plastic Blade Set of 3 AP31210 12 Support Cable Bag Containing HDWFP3120 Ceiling Support Cable Cable Clamp Flat Washer Lag Bolt 3 8 x 2 Hardware Bag Containing 5 32 Threaded Rods 2 5 32 External Lockwasher 2 Knurled Knobs 2 Screw with spring washer 5 32 32 x 8 mm 4 Final Glass Fastener 4 Final Rubber Glass Sleeve 4 Wire Connectors 4 Blade Holder Mounting Hardware Bag Cont...

Страница 13: ...13 NOTE The illustration shown is not to scale or its actual configuration may vary The Vetricco FP3120 Exploded View 4 1 Figure 1 3 2a 8 12 ref 7 6 5 14 10 11 2b 2c 2d 2 13 12 Reversing Switch 9 ...

Страница 14: ...the motor flywheel are tight 4 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off 5 Some fan motors are sensitive to signals from solid state variable speed controls Solid state controls are not recommended choose an alternative control method 6 Tighten screws securel...

Страница 15: ......

Страница 16: ...10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com Copyright 2007 Fanimation 2007 08 ...

Отзывы: