1.

Check to see that you have received the following parts:

NOTE: 

If  you  are  uncertain  of  part  description,  refer  to

exploded view illustration.

This Manual Is Designed to Make it as Easy as Possible for You to Assemble,

Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver

One stepladder

Three wire connectors (supplied)

3

Installed Wire Length

Wire Size A.W.G.

4

1

.t

0

5

 

o

p

U

2

1

.t

0

0

1

-

0

5

Unpacking Instructions

For  your  convenience,  check-off  boxes  are  provided  next  to  each  step.  As  each  step  is  completed,  place  a  check

mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should

you be interrupted.

Before  assembling  your  ceiling  fan,  refer  to  section

on proper method of wiring your fan (page 4). If you

feel  you  do  not  have  enough  wiring  knowledge  or

experience,  have  your  fan  installed  by  a  licensed

electrician.

Do  not  install  or  use  fan  if  any  part  is  damaged  or

missing. This product is designed to use only those

parts  supplied  with  this  product  and/or  any

accessories designated specifically for use with this

product  by  Fanimation.  Substitution  of  parts  or

accessories not designated for use with this product

by  Fanimation  could  result  in  personal  injury  or

property damage.

WARNING

!

WARNING

!

One wire stripper

One 1/4” blade

screwdriver

Materials

Wiring  outlet  box  and  box  connectors  must  be  of  type

required  by  the  local  code.  The  minimum  wire  would  be  a

3-conductor (2-wire with ground) of the following size:

NOTE:

Place the parts from the loose parts bags in a small

container  to  keep  them  from  being  lost.  If  any  parts  are

missing contact your local retailer.

• Fan Motor Assembly
• Hanger Bracket Assembly with

screws

• Downrod/Hanger Ball Assembly
• Ceiling Canopy
• Canopy Screw Cover Assembly
• Motor Coupling Cover Assembly
• Blade Arm Set (5)
• Blade Set (5)
• Light Plate Assembly
• Socket Plate Assembly
• Three 40W Candelabra Light Bulbs
• Glass 
• C24 Remote Control
• Receiver Unit

• Hardware bags:

– 3/16-24 x 8mm

(blade to blade holder)

Washer Head Screw

3/16” Fiber Washer

(blade to blade holder)

– 1/4”-20 x 14mm

(blade arm to motor)

Pan Head Screw

– Phillips Screwdriver, 4”

Four Wire Connectors

Balance Kit

LIGHT PLATE

ASSEMBLY

SOCKET

PLATE

ASSEMBLY

BLADE SET (5)

BLADE ARM SET (5)

HARDWARE BAG

HANGER

BRACKET

ASSEMBLY

W/SCREWS

DOWNROD/

HANGER BALL

ASSEMBLY

CANOPY

SCREW

COVER

ASSEMBLY

MOTOR

COUPLING

COVER

FAN MOTOR

ASSEMBLY

40 WATT

CANDELABRA

LIGHT BULBS (3)

GLASS

CEILING

CANOPY

RECEIVER

UNIT

C24 REMOTE

CONTROL

Содержание The Ventana FP8032SB

Страница 1: ...Model No FP8032 OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS The Ventana Ceiling Fan Finish SB Net Weight 11 1 kg 24 48 lbs ...

Страница 2: ...the defective fan is returned to our national service center Proof of purchase is required Customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs or replacement 2 ONE YEAR MOTOR LABOR WARRANTY If your fan motor fails at any time within one year from the original purchase due to defects in materials or workmanship labor to repai...

Страница 3: ...ion Substitution of parts or accessories not designated for use with this product by Fanimation could result in personal injury or property damage WARNING WARNING One wire stripper One 1 4 blade screwdriver Materials Wiring outlet box and box connectors must be of type required by the local code The minimum wire would be a 3 conductor 2 wire with ground of the following size NOTE Place the parts f...

Страница 4: ...ollar savings could be realized with this simple step Electrical and Structural Requirements If your fan is to replace an existing light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of w...

Страница 5: ... 4 Route wires through motor coupling cover canopy screw cover and canopy Figure 4 5 Reinstall the hanger ball on the downrod as follows Route the three 80 inch wires through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin Securely tighten...

Страница 6: ... for advise as it must be grounded for safe operation The outlet box must be securely anchored Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING 2 Carefully lift the fan and seat the downrod hanger ball assembly on the hanger bracke...

Страница 7: ...n Replace battery cover on the transmitter Figure 2 RECEIVER UNIT DETAIL CODE SWITCHES Figure 3 2 To set the receiver unit code slide code switches to the same positions as set on your transmitter Figure 3 3 Slide the receiver unit into the open end of the hanger bracket Figure 4 4 Connect green wires from hanger bracket and hanger ball to bare ground wire using wire connector supplied Connect bla...

Страница 8: ...de of the outlet box Figure 6 CANOPY SHOULDER SCREWS 2 Figure 1 CANOPY COVER Figure 2 1 Remove one of the two shoulder screws in the hanger bracket Loosen the second shoulder screw without fully removing it Assemble canopy by rotating key slot in canopy over shoulder screw in hanger bracket Tighten shoulder screw Fully assemble and tighten second shoulder screw that was previously removed Figure 1...

Страница 9: ...gh the holes located on the bottom of the motor support Figure 2 NOTE Periodically check blade holder hardware and resecure if necessary 3 Remove one of the three screws in the support bracket at the bottom of the motor assembly Slightly loosen the remaining two screws Assemble the light plate assembly to the support bracket using the two key slots in the socket plate Replace the third screw and s...

Страница 10: ...ve finial nut glass support nut and rubber washer from threaded post on light socket plate Postion glass onto Light Socket Plate Post and secure with rubber washer and glass support nut Assemble finial nut onto threaded shaft Do not over tighten Figure 7 5 Remove one of the three screws in the housing light kit assembly Slightly loosen the remaining two screws Assemble the light socket plate to th...

Страница 11: ...dium and low fan speeds as well as fan off and light on off Infinite light levels are available by holding the light on off button Figure 3 Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until the blades are in place Noise and fan damage could result WARNING REVERSE SWITCH Figure 4 4...

Страница 12: ...s are not required and should be avoided to prevent damage to finish Do not use water when cleaning your ceiling fan It could damage the motor or the finish and create the possibility of electrical shock CAUTION Periodic light dusting of the blades is recommended A feather duster will work best How to Clean Your Ceiling Fan Blades Avoid using water cleansers or harsh rags which can warp and ruin t...

Страница 13: ...s are not recommended choose an alternative control method 6 Tighten screws securely 7 Tighten set screw securely 1 Blades not attached to fan 2 Loose screws in motor housing 3 Screws securing fan blade holders to motor flywheel are loose 4 Wire connectors inside housing rattling 5 Motor noise caused by solid state variable speed control 6 Screws holding blades to blade holders are loose 7 Lower h...

Страница 14: ... Blade Set 5 11 C24 Hand Held Remote Control 12 RECAN65 Receiver Unit 13 HDWFP8032SB s t r a P e s o o L y l b m e s s A g a B 15 14 4 r o t c e n n o C e r i W Washer Head Screw 3 16 24 x 8 mm 16 6 1 6 1 3 r e h s a W r e b i F 14mm w Lock 11 x 0 2 4 1 w e r c S d a e H n a P 4 Phillips Head Screw Driver Balance Kit HOW TO ORDER REPAIR PARTS When ordering repair parts always give the following in...

Страница 15: ...15 2 3 4 7 6 8 9 12 10 5 15 11 8 REF 8 REF 8 REF 14 1 13 NOTE The illustration shown is not to scale or its actual configurations may vary ...

Страница 16: ...Copyright 2009 2009 11 10983 Bennett Parkway Zionsville IN 46077 Toll Free 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Fanimation Website www fanimation com ...

Отзывы: