WARNING
Trouble
Probable Cause
Suggested Remedy
1. Check main and branch circuit fuses or circuit
breakers.
2. Check line wire connections to fan and switch wire
connections in the switch housings.
CAUTION: Make sure main power is turned off !
CAUTION: Make sure main power is turned off !
3. Replace with fresh battery.
1. Attach blades to fan before operating.
2. Check to make sure all screws in motor housing are
snug (not over-tight).
3. Check to make sure the screws which attach the fan
blade to the motor assembly are tight.
1. Tighten both setscrews securely in downrod support.
2. Tighten the setscrew in the downrod/hanger ball
assembly.
3. Check to be sure screws which attach the fan blade
to the motor assembly are tight.
4. Tighten the hanger bracket screws to the outlet box,
1. If possible, consider using a longer downrod (not
included, you can buy the longer downrod from
fanimation.com).
and secure outlet box.
For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan.
1. FAN WILL NOT START
2. FAN SOUNDS NOISY
3. FAN WOBBLES
EXCESSIVELY
4. NOT ENOUGH AIR
MOVEMENT
1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan, or loose
switch wire connections in the switch housing.
3. Dead battery in remote control.
1. Blades not attached to fan.
2. Loose screws in motor housing.
3. Screws securing fan blade to motor assembly are
loose.
4. Lower housing support set screw loose.
1. Setscrew in downrod support is loose.
2. Setscrew in downrod/hanger ball assembly is loose.
3. Screws securing fan blade to motor assembly are
loose.
4. Hanger bracket and/or ceiling outlet box is not
securely fastened.
4. Tighten set screw securely.
Troubleshooting