12

Assembling and Mounting the Fan Blades

Assembling and Mounting the Fan Blades (Continued)

NOTE:  Periodically check Blade Holder hardware and re-
secure if necessary. (see Maintenance below)

WARNING

To reduce the risk of personal injury, do not bend the 
blade holders when installing, balancing the blades or 
cleaning the fan. Do not insert foreign objects in between 
the rotating blades.

Switch Cup Assembly:

Figure 5

x  8

1/4 -20

SCREWS

Figure 6

HARDWARE USED:

2. 

Attach assembled blades and blade holders to 

the motor hub using the provided screws with lock 
washers. Make sure the screws securing the blade 
holders to the motor hub are tight and that the blade 
holders are properly seated. (Figure 2)

Figure 2

Screw
(2 per blade 
holder)

Motor
Assembly

Figure 3

Figure 4

3. 

Remove the six screws in the motor assembly

and retain the screws for reassembly in steps 4 
and 5. (Figure 3) 

 

4. 

Attach the adapter-switch cup to the support 

flange using three of the previously removed six 
screws and fully tighten. (Figure 4)  

5. 

Attach the inner-switch cup to the support flange  

using the remaining three screws and fully tighten. 
(Figure 5)  

  

6. 

Assemble the cover-switch cup assembly to the 

inner-switch cup by twisting in a clockwise direction. 

  

(Figure 6)

Adapter-Switch Cup

Inner-Switch 
Cup 

Inner-Switch 
Cup 

cover-switch 
cup assembly 

Содержание Levon Custom BPW7913BL

Страница 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Net Weight 18 96 lbs 8 6 kgs Model No MAD7912 The Levon Custom 8 Bladed Ceiling Fan...

Страница 2: ...f the fan and blades when cleaning painting or working near the fan Always turn off the power to the ceiling fan before servicing 4 Do not insert anything into the fan blades while the fan is operatin...

Страница 3: ...an How to Hang Your Ceiling Fan How to Wire Your Ceiling Fan Installing the Canopy Housing 4 5 5 7 9 10 11 Assembling and Mounting the Fan Blades 11 How to Operate Your Ceiling Fan 13 Maintenance How...

Страница 4: ...Motor Assembly Downrod Hanger Ball Assembly Ceiling Canopy blade screwdriver Four wire connectors supplied WARNING Do not install or use fan if any part is damaged or missing This product is designed...

Страница 5: ...draft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional energy and dollar savings could be realized with thi...

Страница 6: ...wo joists and takes the place of wooden blocking To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a...

Страница 7: ...e the hairpin clip and clevis pin from the bottom of downrod Retain the pin and clip for reinstallation in Step 4 Figure 2 Hairpin Clip Clevis Pin 1 Remove the hanger ball portion from the downrod han...

Страница 8: ...lows Route the two 80 in wires through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger bal...

Страница 9: ...ws and washers supplied with the outlet box Figure 3 NOTE Outlet box screws pass through slotted holes of the hanger bracket Figure 3 2 Pull the electric wires in the outlet box down through the openi...

Страница 10: ...Ground Listed Outlet Box Household Supply Black Wire from Supply Black Wire from Fan x 3 WIRE CONNECTORS HARDWARE USED NOTE If you feel that you do not have enough electrical wiring knowledge or exper...

Страница 11: ...ing up Assemble the blade to the blade holder with the carriage nuts flat washer and screws Make sure that the blades are fully seated against the blade holders Tighten screws with screwdriver provide...

Страница 12: ...washers Make sure the screws securing the blade holders to the motor hub are tight and that the blade holders are properly seated Figure 2 Figure 2 Screw 2 per blade holder Motor Assembly Figure 3 Fig...

Страница 13: ...dly Figure 3 4 Remote Control Setting and Speed RPM Setting Process Figure 4 For illustrative purposes only not intended to cover all types of controls 1 IMPORTANT Using a full range dimmer switch not...

Страница 14: ...eiling Fan continued Figure 5 Figure 6 5 The remote buttons instruct as below Figure 5 I minimum speed II low speed III medium low speed IV medium speed V medium high speed VI high speed Turns the fan...

Страница 15: ...ntaining HDWMAD7912 Blade Holder Mounting Hardware Bag Containing Blade Mounting Hardware Bag Containing Ref Description Part Motor Coupling Cover Assembly Fan Motor Assembly Blade Holder Set Switch C...

Страница 16: ...n o i t a r u g i f n o c s t r a p l a u t c a s t i r o e l a c s o t t o n s i n w o h s n o i t a r t s u l l i e h T y Exploded View Illustration 16 MAD7912 1 2 3 4 5 6 7 7a 7b 7c 8 11 9 10 purc...

Страница 17: ...Before discarding packaging materials be certain all parts have been removed How To Order Parts When ordering repair parts always give the following information Part Number Part Description Fan Model...

Страница 18: ...ed controls Solid state controls are not recommended choose an alternative control method 6 Tighten screws securely 3 FAN WOBBLES EXCESSIVELY 1 Setscrew and nut in downrod support is loose 2 Setscrew...

Страница 19: ...Copyright 2015 Fanimation 2015 08 V 01 10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com...

Страница 20: ...The Levon Custom 8 aspas Ventilador de techo Peso neto 8 6 kg 18 96 lb MANUAL DEL PROPIETARIO LEA Y GUARDE ESTAS INSTRUCCIONES Modelo N MAD7912...

Страница 21: ...propietario para ver los requisitos de soporte Si tiene dudas consulte a un electricista calificado Las aspas del ventilador deben instalarse por lo menos a 2 m 7 pies del suelo a fin de evitar un con...

Страница 22: ...para determinado fin hasta donde la ley lo permita Algunos estados no permiten limitaciones sobre las garant as impl citas Fanimation no se har responsable por da os accidentales resultantes o especi...

Страница 23: ...dor peque o para evitar que se extrav en Si faltan piezas p n gase en contacto con su proveedor local Materiales W 14 12 NOTA Si no est seguro de la descripci n de una pieza consulte la ilustraci n de...

Страница 24: ...salgunassugerencias para asegurar un rendimiento eficiente del producto Selecci n del lugar de montaje adecuado Los ventiladores de techo se deben instalar en el centro de la habitaci n a 2 13 m 7 pie...

Страница 25: ...tar posibles descargas el ctricas aseg rese de que la electricidad est desconectada en la caja de fusibles principal antes de realizar la instalaci n el ctrica Toda instalaci n el ctrica debe cumplir...

Страница 26: ...rte del barral Instale el barral en el acoplador Alinee los orificios del pasador en el barral con los orificios del soporte del mismo Figura 3 4 Instale el pasador y el pasador de horquilla y apriete...

Страница 27: ...NOTA Se deben revisar todos los tornillos de fijaci n y volver a ajustarlos cuando sea necesario antes de realizar la instalaci n 6 Vuelva a colocar la semiesfera en el barral como se indica a continu...

Страница 28: ...s de los orificios que se encuentran en el soporte de suspensi n Figura 3 2 Pase los cables el ctricos de la caja de distribuci n el ctrica a trav s de la abertura del soporte de suspensi n d blelosh...

Страница 29: ...e las aspas est n instaladas Podr a ocasionar ruidos y da os al motor ADVERTENCIA C mo realizar la instalaci n el ctrica del ventilador de techo 1 Conecte el conductor verde con conexi n a tierra de l...

Страница 30: ...gundo tornillo de reborde que antes hab a retirado y aj stelo Figura 1 2 Coloque y ajuste firmemente la cubierta para el tornillo de la base sobre los tornillos de reborde de la abrazadera para colgar...

Страница 31: ...y montaje de las aspas del ventilador y la caja del interruptor cont Tornillos 2 por soporte de aspas x 16 Aditamentos utilizados Tornillos con arandelas de seguridad FG NOTA Peri dicamente verifique...

Страница 32: ...a os ADVERTENCIA El receptor del sistema de los controladores NOTA se caracteriza por la funci n de aprendizaje autom tico No hay interruptores de frecuencia en la unidad del receptor El receptor ya q...

Страница 33: ...ada para evitar la obstrucci n de las palas las palas del ventilador el motor dejar a de funcionar tas 30 segundos de interrupci n Extraiga los obst culos antes de restaurarlo Protecci n sobre 80 W Cu...

Страница 34: ...contiene HDWMAD7912 Bolsa de accesorios para el montaje de los soportes de aspas que contiene Bolsa de accesorios para el montaje de aspas que contiene Soportes de aspas Unidad la copa de la interrup...

Страница 35: ...ece 35 MAD7912 1 2 3 4 5 6 7 7a 7b 7c 8 11 9 10 Se compra por separado Producto partes est n sujetas a cambios sin previo aviso NOTA OD LOXVWUDFLyQ TXH VH PXHVWUD QR HVWi KHFKD D HV FDOD VX FRQ JXUDFL...

Страница 36: ...nidad del Placa del luz Unidad del kit de iluminaci n AP791206 1 BPW7912 B7912 B7913 B7914 36 1 2 AP791204 Juego de aspa C mo hacer un pedido de piezas Al hacer un pedido de piezas de repuesto proporc...

Страница 37: ...e estado s lido variables Los controles de estado s lido no son recomendables Escoja un m todo de control alternativo 6 Ajuste bien los tornillos 3 EL VENTILADOR OSCILA EN EXCESO 1 El tornillo de fija...

Страница 38: ...15 Fanimation 2015 08 V 01 V 10983 Bennett Parkway Zionsville IN 46077 Llame sin cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 317 733 4113 isite nuestro sitio Web en www fa...

Отзывы: