Fanimation FP7410 Скачать руководство пользователя страница 15

15

Trouble Shooting

WARNING

For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan.

Trouble

Probable Cause

Suggested Remedy

1.  FAN  WILL  NOT  START

1.

  Fuse or circuit breaker blown.

2.

  Loose power line connections to the fan, or loose 

switch wire connections in the switch housing.

3.

  Reversing switch in neutral position.

1.

  Check main and branch circuit fuses or circuit 

breakers.

2.

  Check line wire connections to fan and switch wire 

connections in the switch housings.

CAUTION: Make sure main power is turned off !

3.

  Make sure reversing switch position is all the way to 

one side.

2.  FAN  SOUNDS  NOISY

1.

  Blades not attached to fan.

2.

  Loose screws in motor housing.

3.

  Screws securing fan blade holders to motor flywheel 

are loose.

4.

  Wire connectors inside housing rattling.

5.

  Motor noise caused by solid state variable speed 

control.

6.

  Screws holding blades to blade holders are loose.

7.

  Lower housing support set screw loose.

1.

  Attach blades to fan before operating.

2.

  Check to make sure all screws in motor housing are 

snug (not over-tight).

3.

  Check to make sure the screws which attach the fan 

blade holders to the motor flywheel are tight.

4.

  Check to make sure wire connectors in switch 

housing are not rattling against each other or against 

the interior wall of the switch housing.

CAUTION: Make sure main power is turned off !

5.

  Some fan motors are sensitive to signals from 

solid-state variable speed controls.  Solid-state controls 

are not recommended, choose an alternative control 

method.

6.

  Tighten screws securely.

7.

  Tighten set screw securely.

3.  FAN  WOBBLES

     EXCESSIVELY

1.

  Setscrew in downrod support is loose.

2.

  Setscrew in downrod/hanger ball assembly is loose.

3.

  Screws securing fan blade holders to motor hub are 

loose.

4.

  Blade holders not seated properly. 

5.

  Hanger bracket and/or ceiling outlet box is not

securely fastened.

6.

  Fan blades out of balance. 

1.

  Tighten both setscrews securely in downrod support. 

2.

  Tighten the setscrew in the downrod/hanger ball 

assembly. 

3.

  Check to be sure screws which attach the fan blade 

holders to the flywheel are tight. 

4.

  Check to be sure the fan blade holders seat firmly 

and uniformly to the surface of the motor housing. If 

holders are seated incorrectly, loosen the screws and 

retighten.

5.

  Tighten the hanger bracket screws to the outlet box, 

and secure outlet box. 

6.

  Interchanging position of fan blades can redistribute 

the weight and result in a smoother operation. For 

example, exchange blades in positions 1 and 3 or 1 and 

4. If this does not improve wobble, exchange 2 and 3 or 

2 and 4.

4.  NOT  ENOUGH  AIR

     MOVEMENT

1.

  If possible, consider using a longer downrod.  For 

example, use a 12” downrod instead of the 6” downrod 

that comes with your fan.

Содержание FP7410

Страница 1: ...eiling Fans Windpointe Fan Model Std Net Weight lbs Net Weight kgs 28 46 12 91 27 75 26 29 12 58 11 95 FP7300 FP7400 FP7410 FP7500 FP7510 FP7500RSP4LK 25 57 1 60 25 57 33 25 15 1 1 60 FP7410 4 Bladed...

Страница 2: ...mount of wobble is normal and should not be considered a problem or a defect LIMITED LIFETIME WARRANTY Extends to the original purchaser of a Fanimation Fan Important Safety Instructions WARNING To av...

Страница 3: ...ver One wire stripper Three wire connectors supplied Ceiling Canopy Blade Set not shown see parts list for more details Hardware bags 20 x 20 x 14 blade holder to fan motor hub screws with lockwashers...

Страница 4: ...need to be replaced Consult a qualified electrician if in doubt Energy Ef cient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the c...

Страница 5: ...nopy on fan shown with open side facing up Figure 3 5 Reinstall the Hanger Ball Figure 1 on the Downrod as follows Route the three 80 wires and cable through the Hanger Ball Position the Pin through t...

Страница 6: ...he flat washer safety cable loop and into the building structure Figure 2 You will first drill a pilot hole into the building structure to prevent splitting or cracking 2 Securely attach the hanger br...

Страница 7: ...isted Outlet Box Black Green Wire Ground from Hanger Bracket Green Wire Ground Black Fan Wire White Blue Green Wire Ground from Hanger Bowl Figure 1 WARNING To avoid possible electrical shock be sure...

Страница 8: ...Switch Cup Adapter assembly by removing three screws Figure 4a 7b Disassemble the Switch Cup Adapter Assembly with Light Fitter by removing three screws Figure 4b 8 Remove one of the three screws in...

Страница 9: ...y process Assembling and Mounting the Fan Blades and Switch Hsg cont d 9a Assemble the Adapter assembly on the Housing Support bracket and tighten three screws Securely attach the 9 pins witch cup con...

Страница 10: ...pull chains and fobs Figure 3 Bulb is pressurized and may shatter DO NOT TOUCH BULB WITH BARE HANDS Fingerprints may result in shorter bulb life Remove fingerprints with alcohol prior to use To reduce...

Страница 11: ...main fuse box Figure 1 3 If airflow is desired in the opposite direction turn the fan off and wait for the blades to stop turning Then slide the reverse switch to the opposite position and turn fan on...

Страница 12: ...ing HDWFP51 5 32 Threaded Rods 2 HDWHW50 5 32 External Lockwasher 2 Knurled Knobs 2 Blade Balance Kit BALKT Chain Coupler Chain Fob Wire Connectors 4 Blade Mounting Hardware Bag Containing HDWBM51 3 1...

Страница 13: ...20 x Phillips Head Screws with Lock 20 x 14mm Pan Head Screws with Lock Washers Model FP7500RSP4LK Washers Philips Screwdriver 4 Support Cable Bag Containing Ceiling Support Cable with Clamp Lag Bolt...

Страница 14: ...d View NOTE The illustration shown is not to scale or its actual configuration may vary Figure 1 7 11 5 4 3 1 2a 2b 2c 2d 2 8 7 8 7 8 FP7300 Blade Holders FP7400 FP7410 Blade Holders FP7500 FP7510 FP7...

Страница 15: ...other or against the interior wall of the switch housing CAUTION Make sure main power is turned off 5 Some fan motors are sensitive to signals from solid state variable speed controls Solid state con...

Страница 16: ...Copyright 2011 Fanimation 2011 10 V 01 10983 Bennett Parkway Zionsville IN 46077 Toll Free 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com...

Страница 17: ...techo FP7300 modelo de 3 aspas FP7400 modelo de 4 aspas FP7410 modelo de 4 aspas FP7500 modelo de 5 aspas FP7500RSP4LK modelo de 5 aspas FP7510 modelo de 5 aspas Modelo de ventilador Windpointe est nd...

Страница 18: ...ional Se requiere comprobante de venta El cliente se har responsable de todos los gastos de remoci n o reinstalaci n y env o del producto para reparaciones o sustituci n 2 GARANT A DE MANO DE OBRA DEL...

Страница 19: ...p ngase en contacto con su proveedor local Herramientas necesarias para el ensamblaje Materiales tama o del cable seg n el A W G Calibre de Alambre Estadounidense longitud del cable instalado 14 12 h...

Страница 20: ...ede ahorrar energ a adicional y dinero Requisitos el ctricos y estructurales Su nuevo ventilador de techo requiere una l nea de suministro el ctrico con conexi n a tierra de 120 voltios de CA 60 Hz ci...

Страница 21: ...el barral como se indica a continuaci n Pase los tres cables de 2 m 80 y el cable de seguridad a trav s de la semiesfera Pase el pasador a trav s de los dos orificios en el barral y alinee la semiesf...

Страница 22: ...a trav s de la arandela plana y el aro del cable de seguridad hacia adentro de la estructura del edificio Figura 2 Primero taladre un orificio gu a de 0 6 cm en la estructura del edificio para preveni...

Страница 23: ...alaci n el ctrica NOTA si no est seguro si la caja de distribuci n el ctrica tiene conexi n a tierra pida asesoramiento a un electricista autorizado ya que la conexi n a tierra es importante para un f...

Страница 24: ...la unidad de la caja del adaptador del interruptor retirando 3 tornillos Figura 4a ADVERTENCIA Para reducir el riesgo de lesiones personales no doble los soportes de aspas al instalarlos balancear la...

Страница 25: ...l interruptor de 9 pasadores al enchufe del mazo de cables dentro del adaptador Figura 6a 9b S LO FP7500RSP4LK Conecte el conector de 2 clavijas desde el colocador de iluminaci n de la carcasa de la c...

Страница 26: ...NO TOQUE LA BOMBILLA CON LAS MANOS DESPROTEGIDAS Las huellas dactilares en la bombilla pueden reducir la vida til de la misma Elimine las huellas dactilares con alcohol antes de usar la bombilla Para...

Страница 27: ...nvierno Direcci n de rotaci n En direcci n de las manecillasdel reloj En direcci n contraria a las manecillas del reloj Derecha Izquierda Posici n del interruptor 4 S LO FP7500RSP4LK l e r a b o r p m...

Страница 28: ...el montaje de aspas que contiene HDWBM51 HDWBM55 Tornillos con cabeza de arandela de 3 16 24 x 11 mm modelos FP7300 y FP7400 Tornillos con cabeza de arandela de 3 16 24 x 17 mm modelo FP7500 Tuercas...

Страница 29: ...s 4 Bolsa de accesorios para el montaje de aspas que contiene Tornillos con cabeza de arandela de 3 16 24 x 11 mm modelos FP7300 y FP7400 Tornillos con cabeza de arandela de 3 16 24 x 17 mm modelo FP7...

Страница 30: ...lustraci n que se muestra no est hecha a escala y su con guraci n real puede variar Figura 1 Soportes de aspas FP7300 Soportes de aspas FP7400 y FP7410 Soportes de aspas FP7500 FP7510 y FP7500RSP4LK 7...

Страница 31: ...los controles de velocidad de estado s lido variables Los controles de estado s lido no son recomendables Escoja un m todo de control alternativo 6 Ajuste bien los tornillos 7 Asegure bien los tornill...

Страница 32: ...11 Fanimation 2011 10 V 01 10983 Bennett Parkway Zionsville IN 46077 Llame Sin Cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 317 733 4113 Visite nuestro sitio Web en www fan...

Отзывы: