Fanimation FP5420OB Скачать руководство пользователя страница 4

4

Electrical and Structural Requirements

Your new ceiling fan will require a grounded electrical 
supply line of 120 volts AC, 60 Hz, 15 amp circuit.  The 
outlet box must be securely anchored and capable of 
withstanding a load of at least 50 lbs.  

Figure 1

 depicts 

different structural configurations that may be used for 
mounting the outlet box.

If your fan is to replace an existing light fixture, turn 
electricity off at the main fuse box at this time and remove 
the existing light fixture.

Ceiling

Ceiling

Joists

2

˝

 x 4

˝

Outlet

Box

Figure 1

WARNING

To avoid fire or shock, follow all wiring instructions 

carefully.  Any electrical work not described in these 

instructions should be done or approved by a licensed 

electrician.

WARNING

Turning off wall switch is not sufficent.  To avoid 

possible electrical shock, be sure electricity is turned 

off at the main fuse box before wiring.  All wiring must 

be in accordance with National and Local codes and the 

ceiling fan must be properly grounded as a precaution 

against possible electrical shock.

WARNING

To reduce the risk of fire, electrical shock, or personal 

injury, mount fan to outlet box marked acceptable 

for fan support of 22.7 kg (50 lbs) or less. Use screws 

supplied with outlet box.  Most outlet boxes commonly 

used for support of light fixtures are not acceptable for 

fan support and may need to be replaced.  Consult a 

qualified electrician if in doubt.

Energy Ef

fi

 cient Use of Ceiling Fans

Ceiling fan performance and energy savings rely 
heavily on the proper installation and use of the ceiling 
fan.  Here are a few tips to ensure efficient product 
performance.

Choosing the Appropriate Mounting Location

Ceiling fans should be installed, or mounted, in the middle 
of the room and at least 7 feet above the floor and 18 
inches from the walls. If ceiling height allows, install the fan 
8 - 9 feet above the floor for optimal airflow. Consult your 
Fanimation Retailer for optional mounting accessories.

Turn Off When Not in the Room

Ceiling fans cool people, not rooms. If the room is 
unoccupied, turn off the ceiling fan to save energy.

Using the Ceiling Fan Year Round
Summer Season:

 Use the ceiling fan in the counter-

clockwise direction.  The airflow produced by the ceiling 
fan creates a wind-chill effect, making you “feel” cooler. 
Select a fan speed that provides a comfortable breeze, 
lower speeds consume less energy.

Winter Season:

 Reverse the motor and operate the ceiling 

fan at low speed in the clockwise direction. This produces 
a gentle updraft, which forces warm air near the ceiling 
down into the occupied space.Remember to adjust your 
thermostat when using your ceiling fan - additional energy 
and dollar savings could be realized with this simple step!

Содержание FP5420OB

Страница 1: ...Model No FP5420PW The Celano Ceiling Fan Net Weight 9 07 kg 20 0 lbs OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS...

Страница 2: ...Extends to the original purchaser of a Fanimation Fan Important Safety Instructions WARNING To avoid fire shock and serious personal injury follow these instructions 1 Read your owner s manual and saf...

Страница 3: ...ket Plate Assembly Glass Frame Down Light Kit Lower Housing Cover C24 Remote Control Receiver Unit Downlight Socket Plate Assembly Downlight Glass Housing Assembly Lower Housing Cover Hardware Bags Fa...

Страница 4: ...mmonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt Energy Efficient Use of Ceiling Fans Ceiling fan pe...

Страница 5: ...ight and are properly seated Do not overtighten Figures 2a 2b Figure 1a Figure 2a Figure 1b Figure 2b Figure 3 Screw 3 Pin Setscrew Hanger Ball Figure 4 4 Remove the Hanger Ball by loosening the setsc...

Страница 6: ...in is captured in the groove in the top of the Hanger Ball Pull the Hanger Ball up tight against the pin Securely tighten the setscrew in the Hanger Ball A loose setscrew could create fan wobble 9 Whi...

Страница 7: ...ure 2 Outlet Box Hanger Bracket Outlet Box Hanger Bracket Screw 2 Supplied with Outlet Box Tab Downrod Hanger Ball Assembly WARNING Failure to seat tab in groove could cause damage to electrical wires...

Страница 8: ...IGHT to BLUE light wire Position all connected wires and receiver antenna to allow installation of ceiling canopy To install ceiling canopy see page 9 3 After making the wire connections the wires sho...

Страница 9: ...e electricity is turned off before installing downlight assembly Figure 1a Figure 1b NOTE This step is applicable after the necessary wiring is completed WARNING To avoid possible fire or shock make s...

Страница 10: ...mbly Figure 5 6 Carefully install the Glass Frame Light Kit Assembly into the Adapters slots Figure 6 6 Securely attach the Glass Frame Light Kit Assembly by twisting onto the Adapter plate Don t over...

Страница 11: ...o not over tighten Figure 2b 5 Securely attach the Lower Bowl Housing Assembly by twisting onto the Adapter plate Don t overtighten Figure 4 6 You have now completed the assembly of your ceiling fan R...

Страница 12: ...rasive cleaning agents are not required and should be avoided to prevent damage to finish Periodic light dusting of the blades is recommended A feather duster will work best Avoid using water cleanser...

Страница 13: ...he motor flywheel are tight 4 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power i...

Страница 14: ...522043PW 9 Downlight Socket Plate Assembly AP522041PW 10 Lower Glass Frame Assembly AP542050PW 11 Lower Housing Cover P542020PW 12 Wood Blade Set of 5 P542015 13 Receiver Unit RECAN68 14 Remote Contro...

Страница 15: ...NOTE The illustration shown is not to scale or its actual configuration may vary The Celano FP5420PW Exploded View 4 1 Figure 1 3 2a 8 7 10 11 6 5 13 14 15 12 2b 2c 2d 2 Reversing Switch 9 15...

Страница 16: ...10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com Copyright 2007 Fanimation 2007 11...

Отзывы: