Fanimation FP4620 Series The Zonix Скачать руководство пользователя страница 5

How to Assemble Your Ceiling Fan

Pin

Setscrew

Hanger

Ball

Figure 1

1. 

Remove the Hanger Ball by loosening the setscrew 

in the Hanger Ball until the ball falls freely down the 
Downrod. (Figure 1)  Remove the Pin from the Downrod, 
then remove the Hanger Ball.  Retain the Pin and Hanger 
Ball for reinstallation in Step 5.

2. 

The fan comes with blue, black and white 80

˝

 wires. 

Separate & untwist the three wires and safety cable. Route 
the wires through the downrod.

NOTE: 

 You will be using either the 6

˝

 downrod supplied with 

your fan or an optional downrod purchased separately.

3.

 Loosen the two setscrews in the Downrod Support.  Align 

the Clevis Pin holes in the Downrod with the holes in the 
Downrod Support.  Install the Clevis Pin and secure with 
the Hairpin Clip. (Figure 3)  Be sure to push the straight 
leg of the hairpin clip through the hole near the end of the 
clevis pin until the curved portion of the hairpin clip snaps 
around the clevis pin.  The hairpin clip must be properly 
installed to prevent the clevis pin from working loose. Pull 
on the Downrod to make sure the clevis pin is properly 
installed.

4. 

Route wires through Motor Coupling Cover, Canopy 

(with Canopy Screw Cover) on fan shown with open side 
facing up. (Figure 3)

5. 

Reinstall the Hanger Ball (Figure 1) on the Downrod 

as follows.  Route the three 80

˝

 wires and cable through 

the Hanger Ball.  Position the Pin through the two holes 
in the Downrod and align the Hanger Ball so the Pin is 
captured in the groove in the top of the Hanger Ball.  Pull 
the Hanger Ball up tight against the pin. 

Securely tighten 

the setscrew in the Hanger Ball.  A loose setscrew 
could create fan wobble.

6. 

While pulling up on the hanger ball, securely tighten the 

two setscrews with nuts in the downrod support. Slide the 
Motor Coupling Cover down on top of the motor housing.
(Figures 2 & 3)

7. 

Before installing fan, measure up approximately 6-9 

inches above top of Downrod/Hanger Ball Assembly.  Cut 
off excess wire and strip back insulation ½

˝

 from end of 

wire.

8. 

All set screws must be checked and retightened where 

necessary before installation.

9.

 You have now completed the upper assembly of your 

new ceiling fan.  You can now proceed with the hanging 
and the electrical wiring of your fan.

Clevis Pin

Motor

Coupling

Cover

Figure 2

Figure 3

Hairpin Clip

Downrod 

Support

WARNING

It is critical that the clevis pin in the downrod support 

is properly installed and the setscrews are securely 

tightened.  Failure to verify that the pin and setscrews 

are properly installed could result in the fan falling.

Setscrew (2)

Reverse 

Switch

5

Содержание FP4620 Series The Zonix

Страница 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Model No FP4620 The Zonix Ceiling Fan Net Weight 9 07 kg 20 lbs...

Страница 2: ...ry from state to state 10 A certain amount of wobble is normal and should not be considered a problem or a defect LIMITED LIFETIME WARRANTY Extends to the original purchaser of a Fanimation Fan Import...

Страница 3: ...Screw Cover Motor Coupling Cover Adapter Plate Lower Cover Assembly Wood Blades 3 CW40 Wall Control Adapter Plate Hardware Bags CW40 Wall Control Fan Motor Assembly Lower Cover Assembly Downrod Hanger...

Страница 4: ...n doubt Electrical and Structural Requirements Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here a...

Страница 5: ...n fan shown with open side facing up Figure 3 5 Reinstall the Hanger Ball Figure 1 on the Downrod as follows Route the three 80 wires and cable through the Hanger Ball Position the Pin through the two...

Страница 6: ...ure 2 Outlet Box Hanger Bracket Outlet Box Hanger Bracket Screw 2 Supplied with Outlet Box Tab Downrod Hanger Ball Assembly WARNING Failure to seat tab in groove could cause damage to electrical wires...

Страница 7: ...curely attach the Canopy Housing over the shoulder screws Figure 1a 3 Securely attach and tighten the Canopy Screw Cover over the shoulder screws in the Hanger Bracket utilizing the keyslot twist lock...

Страница 8: ...tach the Switch Cup Support Plate to the support flange by rotating plate and properly positioning screws in key slots Install fourth screw in remaining hole Fully tighten all four screws Figure 5 Fig...

Страница 9: ...tor or the blades and create the possibility of electrical shock Operating Instructions CW40 Wall Control Figure 1 Blade Cleaning Periodic light dusting of the blades is recommended A feather duster w...

Страница 10: ...Assembly AMA4620 7 Switch Cup Cover Assembly with Flat Head Screws 3 AP462010 8 Blade Set 3 AP462007 9 Wall Control CW40 10 Hardware Bag Containing HDWFP4620 Blade Balance Kit BALKT HDWHW4620 Wire Co...

Страница 11: ...The Zonix Model FP4620 Exploded View 1 3 4 2a 2b 2c 2d 2 7 NOTE The illustration shown is not to scale or its actual configuration may vary Product parts are subject to change without notice Figure 1...

Страница 12: ...other or against the interior wall of the switch housing CAUTION Make sure main power is turned off 5 Some fan motors are sensitive to signals from solid state variable speed controls Solid state con...

Страница 13: ......

Страница 14: ...Copyright 2008 Fanimation 2008 02 10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com...

Отзывы: