Fanimation Breckenfield FP7951 Скачать руководство пользователя страница 2

1.   LIMITED LIFETIME MOTOR WARRANTY - If any part of your fan motor fails, due to a defect in materials or workmanship during 

the lifetime of the original purchaser, Fanimation will provide the replacement part free of charge, when the defective fan is returned 

to our national service center.  Proof of purchase is required.  Customer shall be responsible for all costs incurred in the removal or 

reinstallation and shipping of the product for repairs or replacement.

2.   ONE YEAR MOTOR LABOR WARRANTY - If your fan motor fails at any time within one year from the original purchase, due to 

defects in materials or workmanship, labor to repair the motor will be provided free of charge at our national service center.  Purchaser 

will be responsible for labor charges after this one-year period.  Customer shall be responsible for all costs incurred in the removal or 

reinstallation and shipping of the product for repairs or replacement.

3.   If any other part of your fan fails at any time within one year after original purchase, due to a defect in materials or workmanship, we 

will repair, or replace, at our option, the defective part free of charge for parts and labor performed at our national service center.

4.   Because of varying climate conditions, this warranty does not cover changes in the finish, including rusting, pitting, corroding, 

tarnishing, or peeling.

5.  This warranty is void and does not apply to damage from improper installation, neglect, accident, misuse, exposure to extremes of 

heat or humidity, or as a result of any modification to the original product.

6.   All costs of removal and reinstallation of the fan are the sole responsibility of the owner of the fan and not the store that sold the fan 

or Fanimation.

7.   Fanimation reserves the right to modify or discontinue any product at any time and may substitute any part under this warranty.

8.   Under no circumstances may a fan be returned without prior authorization from Fanimation.  The receipt of purchase must ac-

company authorized returns and must be sent freight prepaid to Fanimation.  The fan to be returned must be properly packed to avoid 

damage in transit; Fanimation will not be responsible for any damage resulting from improper packaging.

9.   It is understood that any repair or replacement is the exclusive remedy available from Fanimation.  There is no other expressed or 

implied warranty.  Fanimation hereby disclaims any and all implied warranties, including, but not limited to those of merchantability and 

fitness for a particular purpose to the extent permitted by law.  Some states do not allow limitations on implied warranties.  Fanimation 

will not be liable for incidental, consequential, or special damages arising out of or in conjunction with product use or performance, 

except as may otherwise be accorded by law.  This warranty gives you special legal rights and you may also have other rights that vary 

from state to state.

10. A certain amount of wobble is normal and should not be considered a problem or a defect.

LIMITED LIFETIME WARRANTY

Extends to the original purchaser of a Fanimation Fan

Important Safety Instructions

WARNING: To avoid fire, shock and serious personal injury, follow these instructions.

1.   Read your owner’s manual and safety information before installing your new fan.  Review the accompanying assembly diagrams.

2.   Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power 

from being switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a warning device, such 

as a tag, to the service panel.

3.   Be careful of the fan and blades when cleaning, painting, or working near the fan.  Always turn off the power to the ceiling fan before 

servicing.

4.   Do not insert anything into the fan blades while the fan is operating.

5.   Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions

1.   To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.   All wiring and installation procedures must satisfy National Electrical Codes (ANSI/ NFPA 70-1999) and Local Codes.  The ceiling fan 

must be grounded as a precaution against possible electrical shock.  Electrical installation should be made or approved by a licensed 

electrician.

3.   The fan base must be securely mounted and capable of reliably supporting at least 50 lbs.  Consult a qualified electrician if in doubt.

4.   The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

5.   Follow the recommended instructions for the proper method of wiring your ceiling fan.  If you do not have adequate electrical 

knowledge or experience, have your fan installed by licensed electrician.

WARNING:

  Suitable for use with solid-state speed control.

WARNING:

  This product is designed to use only those parts supplied with this product and/or accessories designated specifically for 

use with this product.  Using parts and/or accessories not designated for use with this product could result in personal injury or property 

damage.

WARNING:

WARNING:  

 Use only with light kits marked suitable for use in damp locations.

WARNING:  

 To reduce the risk of electric shock, this fan must be installed with an isolating, general use wall control/switch.

  To reduce the risk of personal injury, do not bend the blade bracket (flange or blade holder) when installing the brackets, 

balancing the blades, or cleaning the fan.  Do not insert foreign objects in between rotating fan blades.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 

(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including 

interference that may cause undesired operation. If the intentional radiator can be classified as a Class B digital device or a PC 

peripheral, then shall include the following or equivalent:

Note:

 This equipment has been tested and found to comply with the limits for Class B digital device, pursuant to part 15 of the 

FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the

instructions, may cause harmful interference to radio or television reception, which can be determined by turning the 

equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

- Reorient or relocate the receiving antenna. 

- Increase the separation between the equipment and the receiver.

- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help. 

Note:

 For a Class A digital device, statements of 15. 105(a) must be included when appropriate for the device in question.

Содержание Breckenfield FP7951

Страница 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Model No FP7951 Net Weight 14kg 30 86 lbs The Breckenfield Ceiling Fan...

Страница 2: ...l disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel 3 B...

Страница 3: ...to Assemble Your Ceiling Fan 6 How to Hang Your Ceiling Fan 8 How to Wire Your Ceiling Fan 9 0 1 g n i s u o H y p o n a C e h t g n i l l a t s n I How to assemble the Blades and Light kit 11 How to...

Страница 4: ...ed with this product and or any accessories designated specifically for use with this product by Fanimation Substitution of parts or accessories not designated for use with this product by Fanimation...

Страница 5: ...rooms If the room is unoccupied turn off the ceiling fan to save energy Using the Ceiling Fan Year Round Summer Season Use the ceiling fan in the counter clockwise direction The airflow produced by th...

Страница 6: ...n the two set screws and locking nuts in the downrod support Figure 4 Pin Hanger Ball Set Screw Downrod Fan Motor Assembly Screw 3 Support Bracket Light Plate Assembly Figure 5 5 Remove one of the thr...

Страница 7: ...7 Route wires through motor coupling cover canopy screw cover and canopy Figure 7 8 Reinstall the hanger ball on the downrod as follows Route the three 80 inch wires through the hanger ball Position...

Страница 8: ...shers supplied with the outlet box Figure 2 NOTE Outlet box screws pass through slotted holes of the hanger bracket Figure 2 2 Pull the electric wires in the outlet box down through the opening in the...

Страница 9: ...ge the combination code in your transmitter and receiver 1 To set the transmitter code remove battery cover by pressing firmly below arrow and sliding cover off Slide code switches to your choice of u...

Страница 10: ...d be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box Figure 6 Figure 6 BLA...

Страница 11: ...de Blade holder Figure 2 Figure 3 HARDWARE USED x 10 1 4 20 x 14 mm SCREWS Motor Assembly 1 4 20 x 14 mm SCREWS 2 per assembly Blade Holder Socket Plate Assembly Socket Plate Single Pin Connector Moto...

Страница 12: ...third screw and securely tighten all three screws Figure 4 5 Insert light bulb into socket Figure 5 6 Remove the three trim screws of support bracket from the housing ring assembly Retain the screws...

Страница 13: ...es buttons for high medium and low fan speeds as well as buttons for fan off and light on off Infinite light levels are available by holding the light on off button Figure 3 Check to see that all conn...

Страница 14: ...ning agents are not required and should be avoided to prevent damage to finish Do not use water when cleaning your ceiling fan It could damage the motor or the finish and create the possibility of ele...

Страница 15: ...sing CAUTION Make sure main power is turned off 5 Tighten screws securely 1 Blades not attached to fan 2 Loose screws in motor housing 3 Screws securing fan blade holders to motor flywheel are loose 4...

Страница 16: ...0 AP795109 AP795114 Blade Set 11 AP795105 Hand Held Remote 12 TR24WH RECAN54 Receiver Unit 13 HDWFP7951 16 14 Washer Head Screw 3 16 24x7 5 mm 16 4 Phillips Head Screw driver Screw 1 4 20x14 mm w Lock...

Страница 17: ...el FP7951 Exploded View 1 3 4 2 7 10 NOTE The illustration shown is not to scale or its actual con guration may vary Product parts are subject to change without notice Figure 1 8 11 12 13 14 16 9 The...

Страница 18: ......

Страница 19: ...Copyright 2012 Fanimation 2012 05 V 01 10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com...

Страница 20: ...Ventilador de techo Modelo N FP7951 MANUAL DEL PROPIETARIO LEA Y GUARDE ESTAS INSTRUCCIONES The Breckenfield Peso neto 14 kg 30 86 lbs...

Страница 21: ...se de que la electricidad est desconectada en la caja de fusibles antes de realizar 1 la instalaci n el ctrica y no haga funcionar el ventilador sin las aspas Todos los procedimientos de conexi n el c...

Страница 22: ...mo realizar la instalaci n el ctrica del ventilador de techo 28 29 23 24 24 25 27 Instalaci n de la cubierta del capuch n C mo ensamblar el ventilador de techo C mo utilizar su ventilador de techo Man...

Страница 23: ...rar de completar todos los pasos y podr saber desde d nde retomar si fuera interrumpido NOTA Si no est seguro de la descripci n de una pieza consulte la ilustraci n del despiece 1 Veri que que haya re...

Страница 24: ...ventilador de techo a velocidad baja y en el sentido de las agujas del reloj Esto produce una suave corriente ascendente que obliga al aire c lido que se acumula cerca del techo a bajar al espacio oc...

Страница 25: ...n y las tuercas de seguridad en el soporte de la varilla interior Figura 4 Ranura de la bola colgante Pasador Tornillo de fijaci n Bola para colgar Tornillo 3 abrazadera de soporte Ensamble de la pla...

Страница 26: ...8 Vuelva a colocar la semiesfera en el barral como se indica a continuaci n Pase los tres cables de 2 03 m 80 a trav s de la semiesfera Pase el pasador a trav s de los dos orificios en el barral y al...

Страница 27: ...la caja de distribuci n el ctrica Pesta a Unidad del barral de la semiesfera ADVERTENCIA Si la pesta a no est en la ranura podr an producirse da os en los cables el ctricos y posibles descargas el ct...

Страница 28: ...ndo el conector de cables suministrado Conecte el cable blanco desde la unidad del receptor marcado AC IN N al cable blanco de suministro de electricidad utilizando el conector de cables suministrado...

Страница 29: ...tilador hasta que las aspas est n instaladas Podr a ocasionar ruidos y da os al motor ADVERTENCIA x 6 Aditamentos utilizados Conectores de cable Instalaci n de la cubierta del capuch n 2 Coloque y aju...

Страница 30: ...te del motor mediante los tornillos de 1 4 20 x 14 mm a trav s de los orificios ubicados al costado del soporte del motor Figura 2 soportes de las aspas y vuelva a ajustarlas si fuese necesario x 10 A...

Страница 31: ...ra 7 C mo ensamblar los Blades y kit de luz cont 4 Extraiga uno de los tres tornillos de la unidad de la placa Afloje levemente los otros dos tornillos Instale la placa de conexi n en la unidad de la...

Страница 32: ...cable pelado en los conectores de cables con la excepci n del cable de toma de tierra No utilice el ventilador hasta que las palas est n colocadas en su lugar ya que de lo contrario se podr a causar r...

Страница 33: ...antenimiento 1 El nico mantenimiento necesario para el ventilador de techo es una limpieza peri dica Al llevar a cabo la limpieza use s lo un cepillo suave o un pa o sin pelusas para evitar rayar el a...

Страница 34: ...erior de la caja del interruptor PRECAUCI N Aseg rese de que el suministro principal de electricidad est desconectado 5 Ajuste bien los tornillos 3 EL VENTILADOR OSCILA EN EXCESO 1 El tornillo de fija...

Страница 35: ...techo Cubierta de uni n del motor Bolsa de accesorios conectores de los cables 4 arandela de la cabeza del tornillo DE 3 16 24 x7 5 mm Arandela de fibr de 3 16 16 tornillo de cabeza troncoc nica de 1...

Страница 36: ...36 6 5 15 Modelo FP7951 Despiece 1 3 4 2 7 10 Figura 1 8 11 12 13 14 16 9 NOTA The Breckenfield...

Страница 37: ......

Страница 38: ...12 Fanimation 2012 05 V 01 10983 Bennett Parkway Zionsville IN 46077 Llame sin cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 317 733 4113 Visite nuestro sitio Web en www fan...