background image

NOTE: 

This step is applicable after the neccessary 

wiring is completed.

How to Install Your Canopy Housing

Shoulder Screw 

1. 

Assemble canopy by rotating key slot in canopy 

over shoulder screw in hanger bracket, taking care not 
to pinch the wires. Tighten shoulder screw. Fully 
assemble and tighten second shoulder screw that was 
previously removed. (Figure 1)

2. 

Securely attach and tighten the canopy screw cover

over the shoulder screws in the hanger bracket
utilizing the key slot twist-lock feature. (Figure 2)

WARNING

To avoid possible fire or shock, make sure that the
electrical wires are completely inside the canopy 
housing and not pinched between the housing and the
ceiling.

Canopy Screw
Cover

Ceiling 
Canopy

Figure 1

Figure 2

12

Figure 1

How to Assemble Your Ceiling Fan Blades

x  21

x  21

Flat Washers

3/16

-24

Serrated Head

Screws

HARDWARE USED:

 

3/16

-24 Serrated Head Screw 

with Flat Washer (3 per blade) 

INSTALLATION NOTE

Do not connect fan blades until the fan is completely
installed. Installing the fan with blades assembled may
result in damage to the fan blades.

WARNING

To reduce the risk of personal injury, do not bend the 
blades when installing, balancing or cleaning the fan. 
Do not insert foreign objects in between the rotating 
blades.

1. 

Carefully slide the blade through the slot as shown.

Securely fasten the seven blades with serrated head
screws with flat washers. Do not over-tighten.
(Figure 1)

Содержание 2483971

Страница 1: ...e Date ATTACH YOUR RECEIPT HERE AND REGISTER YOUR FAN AT FANIMATION COM READ AND SAVE THESE INSTRUCTIONS For best and quick service please provide date code You can find the date code on the Carton Ha...

Страница 2: ...e control unit operate the equipment CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to WARNING This product is designed...

Страница 3: ...e center 4 If any other part of your light kit fails at any time within five years after original purchase due to a defect in materials or workmanship we will repair or replace at our option the defec...

Страница 4: ...embly Not Included One Phillips head screwdriver One blade screwdriver One stepladder One wire stripper 1 Check to see that you have received the following parts NOTE If you are uncertain of part desc...

Страница 5: ...ur Fanimation Retailer for optional mounting accessories Turn Off When Not in the Room Ceiling fans cool people not rooms If the room is unoccupied turn off the ceiling fan to save energy Your new cei...

Страница 6: ...of wooden blocking To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician Figure 3...

Страница 7: ...om the bottom of the downrod Retain the pin and clip for reinstallation in Step 5 Figure 2 Figure 2 WARNING It is critical that the clevis pin in the downrod support is properly installed and the set...

Страница 8: ...screw in the hanger ball A loose set screw could create fan wobble Figure 7 8 Cut off excess lead wire approximately 6 to 9 inches above top of the downrod Strip insulation off 1 2 inch from the end...

Страница 9: ...ptions are not available For angled ceilings note the angle can be no more than 19 WARNING To avoid possible fire or shock be sure electricity is turned off at the main fuse box before hanging Figure...

Страница 10: ...l Figure 1 NOTE The remote unit has 32 different code other remote units simply change the combination code NOTE Factory setting is all up Do not use this position 2 Slide the receiver into the hanger...

Страница 11: ...RED BLACK WHITE BLK ANT GRAY YELLOW GREEN Ground Wire From Hanger Bracket GREEN Ground wire From Ceiling GREEN Ground Wire From Hanger Ball GREEN YELLOW Ground wire 2 From Receiver BLACK WHITE BLUE 4...

Страница 12: ...e the canopy housing and not pinched between the housing and the ceiling Canopy Screw Cover Ceiling Canopy Figure 1 Figure 2 12 Figure 1 How to Assemble Your Ceiling Fan Blades x 21 x 21 Flat Washers...

Страница 13: ...n the light kit Retain the screw for later and slightly loosen the remaining two screws Figure 3 4 If installing the light kit skip this step Assemble the light kit wire cover to the light kit using t...

Страница 14: ...d to control fan speed will damage the fan To reduce the risk of fire or electrical shock do not use a full range dimmer switch to control the fan speed Figure 1 2 Restore electrical power to the outl...

Страница 15: ...on the remote control with previously removed screw by screwdriver Figure 6 7 Remote functions Figure 7 Indicator LED light fan speed and light dimmer indicator button Tap once to turn off the fan Pre...

Страница 16: ...igure 1 Attach wall plate using the two provided screws Periodic cleaning of your new ceiling fan is the only maintenance necessary When cleaning use only a soft brush or lint free cloth to avoid scra...

Страница 17: ...l 4 Make sure reverse switch position is all the way to one side 4 Reverse switch in neutral position 1 Blades not attached to fan 1 Tighten both setscrews and nuts securely in downrod support 1 Setsc...

Страница 18: ...mber located on downrod support Hardware Bag Containing 3 16 24 Serrated Head Screws 22 Stainless Flat Washers 22 Blade Mounting Hardware Bag Containing Motor Coupling Cover Assembly Motor Assembly Do...

Страница 19: ...LP8377LBN Exploded View Illustration 1 2 3 4 5 6 7 9 10 12 14 13 11 14 8 14 NOTE The illustration shown is not to scale or its actual configuration may vary Product parts are subject to change withou...

Страница 20: ...2020 03V 01 Copyright 2020 Fanimation 10983 Bennett Parkway Zionsville IN 46077 Phone 888 567 2055 Outside U S 317 733 4113 FAX 866 482 5215 FANIMATION COM...

Страница 21: ...U Y REGISTRE SU VENTILADOR EN FANIMATION COM LEA Y GUARDE ESTAS INSTRUCCIONES Para ofrecer un servicio r pido y de calidad por favor suministre el c digo de fecha Puede encontrar el c digo de fecha en...

Страница 22: ...en tan solo 2 horas Asegure siempre por completo el compartimento de la pila Si el compartimento de la pila no est cerrado de forma segura deje de utilizar el mando a distancia del producto extraiga l...

Страница 23: ...per odo de un a o El cliente se har responsable de todos los gastos de remoci n o reinstalaci n y env o del producto para reparaciones o sustituci n 3 Si otra pieza del ventilador fallara dentro del...

Страница 24: ...letar todos los pasos y podr saber desde d nde retomar si fuera interrumpido 1 Verifique que haya recibido las siguientes piezas NOTA Si no est seguro de la descripci n de una pieza consulte la ilustr...

Страница 25: ...un flujo de aire ptimo Consulte en su tienda minorista de Fanimation para obtener accesorios de montaje opcionales Apague el ventilador cuando no se encuentre en la habitaci n Los ventiladores son pa...

Страница 26: ...rte de l mparas no son aptas para soporte de ventiladores y es posible que deban reemplazarse Consulte a un electricista calificado si tiene dudas ADVERTENCIA Apagar el interruptor de pared no es sufi...

Страница 27: ...ar Retener el pasador y clip para la reinstalaci n en el paso 5 Figura 2 Figura 2 5 Enrosque el soporte de la varilla y alinee los orificios de la clavija de horquilla en ambas piezas Instale la clavi...

Страница 28: ...2 2 8 6 c m 7 Vuelva a colocar la semiesfera en el barral como se indica a continuaci n Pase los cables de negro blanco azul rojo gris amarillo y cable de soporte para techo a trav s de la semiesfera...

Страница 29: ...el ctrica aseg rese de cortar la alimentaci n el ctrica de la caja de fusibles principal antes de colgar el ventilador Figura 1 ADVERTENCIA La caja de salida debe estar bien asegurada La abrazadera pa...

Страница 30: ...ilador tiene 32 combinaciones diferentes de c digos Para evitar posibles interferencias desde o hacia otros mandos a distancia modifique el c digo de combinaci n de su transmisor y receptor Para evita...

Страница 31: ...Conductor Negro Blanco Conductor Blanco Conductor Negro Conductor Azul Conductor Amarillo antena Verde Amarillo puesta a tierra 2 del Receptor Verdeo puesta a tierra del techo Verdeo puesta a tierra d...

Страница 32: ...empujarse con cuidado en el cuadro de juntura y de que no est n aprisioel techo Tornillo de reborde Figura 1 Figura 2 Capuch n de techo Cubierta para el tornillo del capuch n 32 C mo ensamblar las asp...

Страница 33: ...uarde los tornillos para pasos posteriores Afloje levemente los otros dos tronillos Figura 3 4 Si desea instalar el kit de iluminaci n s ltese este paso Instale la cubierta del cable del kit de ilumin...

Страница 34: ...los tipos de controles C mo utilizar su ventilador de techo Principal Caja De Fusibles 1 IMPORTANTE El uso de un regulador de la intensidad completa no incluido para controlar la velocidad del ventila...

Страница 35: ...ando a distancia con un tornillo retirados previamente Figura 6 Mando a distancia Interruptores Figura 5 Figura 6 C mo utilizar su ventilador de techo cont 7 Funciones del control remoto Figura 7 Luz...

Страница 36: ...efrigerante hacia abajo Invierno El ventilador funciona en el sentido de las agujas del reloj El flujo del aire fuerza el aire caliente hacia abajo sin una brisa visible 36 1 Instalaci n de la placa d...

Страница 37: ...rruptor est n flojas 3 Pila agotada del mando a distancia 4 Aseg rese de que el conmutador inversor est completamente a un lado 4 El conmutador inversor se encuentra en posici n neutra 4 Algunos motor...

Страница 38: ...ra el montaje de aspas que contiene Cubierta de uni n del motor Unidad del motor Unidad del barral de la semiesfera Capuch n de techo Unidad del soporte de suspensi n Lista de piezas Modelos N LP8377L...

Страница 39: ...BLITZ 1 2 3 4 5 6 7 9 10 12 14 13 11 14 8 14 Modelo LP8377LBN Ilustraci n del despiece NOTA La ilustraci n que se muestra no est hecha a escala y su c guraci n real y o terminaci n puede variar 39...

Страница 40: ...2020 03V 01 Copyright 2020 Fanimation 10983 Bennett Parkway Zionsville IN 46077 Llame Sin Cargo al 888 567 2055 Desde fuera de los EE UU llame al 317 733 4113 www fanimation com FAX 866 482 5215...