Instructions of key operation of the remote control are as follows:
1. Power: Press
key to turn ON / OFF the machine.
2. Mode: press
key to switch between cooling, dehumidification, fan and heating (single cold
with no such function) mode.
3. Up: press key to increase temperature and timing set value.
4. Down: press
key to reduce temperature and timing set value.
5. Fan: press
key to select high, medium and low wind speed output circularly.
6. Timer: press
key to set timing value. Timing value can be set with 1-24 hours and the timing
value is adjusted upwards or downwards by one hour.
7. Swing: Press the louver will swing up and down.
8. press
key to switch between Celsius and Fahrenheit.
9. Sleep Mode: Press
key to turn on the sleep mode.
IV. Protection function
3.1
、
Frost Protection Function:
In cooling, dehumidifying or economic power saving mode, if the temperature of the exhaust pipe
is too low, the machine will automatically enter protection status; if the temperature of the exhaust
pipe rises to a certain temperature, it can automatically revert to normal operation.
3.2
、
Overflow Protection Function:
When water in the water pan exceeds the warning level, the machine will automatically sound an
alarm, and the "FULL" indicator light will flash. At this point, you need to move the drainage pipe
connecting the machine or the water outlet to sewer or other drainage area to empty the water
(details see
Drainage Instruction
s at the end of this chapter). After the water is emptied, the
machine will automatically return to the original state.
3.3 Automatic Defrosting (cooling models have this function):
The machine has automatic defrosting function. Defrosting can be achieved through four - way
valve reversing.
3.4
、
Protection Function of the Compressor
To increase the service life of the compressor, it has a 3-minute delay booting protection function
after the compressor is turned off.
V. Installation and adjustment
1.Installation
:
Warning: before using the portable air conditioning, keep it upright for at least two hours.
The air conditioning can be easily moved in the room. In the moving process, ensure that the air
conditioning is in the upright position and the air conditioning should be placed on a flat surface. Do not
install and use the air conditioning in the bathroom or other humid environments.