The air conditioning is only suitable for indoor use, and not suitable for other applications. 

 

Follow local grid interconnection rules while installing the air conditioning and ensure 
that it is properly grounded. If you have any question on electrical installation, follow the 
instructions of the manufacturer, and if necessary, ask a professional electrician to install 
it.   

 

Place the machine in a flat and dry place and keep a distance of above 50cm between the 
machine and the surrounding objects or walls. 

 

After the air conditioning  is  installed, ensure that the power plug  is  intact and firmly 
plugged into the power outlet, and place the power cord orderly to prevent someone from 
being tripped or pulling out the plug. 

 

Do not put any object into the air inlet or outlet of the air conditioning. Keep the air inlet 
and outlet free from obstructions.   

 

When drainage pipes are installed, ensure that the drainage pipes are properly connected, 
and are not distorted or bended. 

 

While adjusting the upper and lower wind-guide  strips of the air outlet, pluck  it with 
hands gently to avoid damaging wind-guide strips. 

 

When moving the machine, make sure that it is in an upright position.   

 

The  machine  should  stay  away  from  gasoline,  flammable  gas,  stoves  and  other  heat 
sources.   

 

Don't disassemble, overhaul and modify the machine arbitrarily, otherwise it will cause a 
machine malfunction or even bring harm to persons and properties. To avoid danger, if a 
machine failure occurs, ask the manufacturer or professionals to repair it. 

 

Do not install and use the air conditioning in the bathroom or other humid environments.   

 

Do not pull the plug to turn off the machine. 

 

Do not place cups or other objects on the body to prevent water or other liquids from 
spilling into the air conditioning. 

 

Do not use insecticide sprays or other flammable substances near the air conditioning. 

 

Do not wipe or wash the air conditioning with chemical solvents such as gasoline and 
alcohol. When you need to clean the air conditioning, you must disconnect the power 
supply, and clean it with a half-wet soft cloth. If the machine is really dirty, scrub with a 
mild detergent.   

 

The appliance can be used by children aged from 8 years and above and persons with 

Содержание PAC-1030

Страница 1: ...INSTRUCTIONS MANUAL PAC 1030 PORTABLE AIR CONDITIONER Read and save these instructions for future reference ...

Страница 2: ...nd Adjustment IV Control Setting V Drainage Instructions VI Maintenance VII Troubleshooting VIII Appendix Thank you for choosing this luxurious and elegant portable air conditioning Please keep the manual for later review and read the manual carefully before use ...

Страница 3: ...nd lower wind guide strips of the air outlet pluck it with hands gently to avoid damaging wind guide strips When moving the machine make sure that it is in an upright position The machine should stay away from gasoline flammable gas stoves and other heat sources Don t disassemble overhaul and modify the machine arbitrarily otherwise it will cause a machine malfunction or even bring harm to persons...

Страница 4: ...re streamlined machine With cooling dehumidification and fan function Continuous Water Drainage Function Control panel with LED display The machine is beautiful and elegant Product is equipped with high quality remote control for easy operation It adopts a user friendly remote control design Outdoor interface is set high to facility assembly and keep the smooth flow of the heat pipe Air filtration...

Страница 5: ...ng process ensure that the air conditioning is in the upright position and placed on a flat surface Do not install and use the air conditioning in the bathroom or other environments where humidity is present 1 1 Install the heat pipe assembly as shown in Fig 1 screw the heat pipe assembly exhaust fitting end into the exhaust port on the rear panel Exhaust Pipe Assembly Window Sealing Plate Assembl...

Страница 6: ...distance to bring both ends of the assembly into contact with the window frame and fix various components of the assembly 1 3 Install the body 1 Move the machine with installed heat pipe and fittings before the window making sure that the distance between the body and walls or other objects shall be least 50 cm as shown in Fig 4 2 Elongate the exhaust pipe and snap the flat end of the exhaust pipe...

Страница 7: ...l be 280 1 500mm and this length is based on the specifications of the air conditioning Do not use extension tubes or replace it with other different hoses otherwise it may cause malfunction Exhaust host must be not blocked otherwise it may cause overheating IV Control Panel Setting I Operating instructions LED Control Panel is as follows 1 Power Key 2 Mode Selection Key 3 Sleep Key 4 Down Key 5 U...

Страница 8: ...e required temperature not available in fan or dehumidifying mode While setting the timer press the up key or down key to select the required time 6 Wind Speed Selection Key In cooling and fan mode press the key to select high or low wind speed operation This key in dehumidifying mode is invalid and the fan will forcibly choose low wind speed operation 7 Timing Key When the unit is turned on press...

Страница 9: ...to increase temperature and timing set value 6 Fan press to select high low wind speed 7 Sleep Mode Press to turn on the sleep mode III A Variety of Protection Functions 3 1 Frost Protection Function In cooling dehumidifying or economic power saving mode if the temperature of the exhaust pipe is too low the machine will automatically enter into protection status if the temperature of the exhaust p...

Страница 10: ...1 When the machine stops after the water is full turn off the machine power and unplug the power plug Notes Please move the machine carefully so as not to spill the water in the water pan at the bottom of the body 2 Place the water container below the side water outlet behind the body 3 Unscrew the drainage cover and unplug the water plug the water will automatically flow into the water container ...

Страница 11: ...ning and maintenance turn off the machine and unplug the plug 1 Clean the surface Clean with surface of machine with a wet soft cloth Don t use chemicals such as benzene alcohol gasoline etc otherwise the surface of the air conditioning will be damaged or even the whole machine will be damaged 2 Clean the filter screen If the filter screen is clogged with dust and the effectiveness of the air cond...

Страница 12: ...irectly tilt the body to discharge the water into other containers 2 Turn on the machine adjust it to low wind ventilation mode and maintain this state until the drainage pipe becomes dry so as to keep the inside of the body in a dry state and prevent it from mildewing 3 Turn off the machine unplug the power plug and wrap the power cord around the wrapping post install the water plug and the drain...

Страница 13: ...than 17 62 The cooling or heating effect is not good There is direct sunlight Pull the Curtain Doors or windows are open there are a lot of people or in cooling mode there are other sources of heat Close doors and windows and add new air conditioning The filter screen is dirty Clean or replace the filter screen The air inlet or outlet is blocked Clear obstructions Big Noise The air conditioning is...

Страница 14: ... the room temperature sensor and related circuitry Note If problems not listed in the table occur or recommended solutions do not work please contact the professional service organization VIII Appendix Schematic Diagram for Cooling Heating model For all the technical and specific parameters please refer to product nameplate Condenser Compressor Evaporator Capillary ...

Страница 15: ...parate collection systems for used electrical and electronic products Please help us to conserve the environment we live in DECLARATION OF CONFORMITY Herewith Amiridis Savvidis S A states that this product complies with the requirements of below directives EMC Directive 14 30 EU Low Voltage Directive 14 35 EU ErP Directive 09 125 EC CE Marking 93 68 EEC RoHS Directive 11 65 EU The detailed declara...