![F&F STR-3 Pico Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/fandf/str-3-pico/str-3-pico_manual_3068588009.webp)
- 9 -
power supply
185÷265 V AC
maximum load current (AC-1/AC-3)
3 A/1,5 A
power consumption
standby
0.15 W
on
0.4 W
control
triggered N level
switch-on time (adjustable)
1 s÷5 min.
power and programming indication
green LED
working temperature
-25÷50°C
terminal
2.5 mm² screw terminals
tightening torque
0.4 Nm
local control terminal
2×DY 1 mm²/l= 10 mm
dimensions
35×36×19 mm
mounting
flush-mounted box ø60
protection level
IP20
The application examples listed below can be downloaded from
the website www.fif.com.pl from the product subpage:
1. Wiring example: one local button mode.
2. Wiring example: two local button mode.
3. Group control example.
4. Example of extensive control with division into additional
groups of roller shutters.
Technical data
Application examples