background image

- 2 -

»

Automatic detection of the nature of the load: R+L, R+C and 

LED. The use of ESL lamps requires manual setting of the na-

ture of the load using the knob on the face of the dimmer;

»

Smooth brightening and dimming to extend the life of the con-

trolled lamp;

»

Adjustable brightening and dimming rates;

»

„Memory” of light intensity settings – after each switch-on, 

the lighting returns to the previously set brightness. Not ap-

plicable to ESL lamps;

»

Adjustment of the minimum illuminance level of the control-

led lamp (especially important for ESL lamps, requiring mini-

mum ignition and holding current);

»

ON mode – switching of the lighting to maximum brightness 

without dimming;

»

Control input galvanically isolated from the dimmer supply 

circuit.

The lighting can be controlled by a number of pushbuttons con-

nected in parallel and located at different points in the room. 

The receiver is switched on to the last set brightness level after 

a current pulse caused by pressing any momentary (bell) button 

connected to the relay. A short press of the button switches the 

lighting on. Pressing and holding the button (for more than 1 se-

cond) changes the brightness level in one direction (brightening 

or dimming). Each time the button is pressed again (for more 

than 1 second), it adjusts in the opposite direction.

Features

Functioning