- 1 -
OM-633
Power consumption limiters
with a voltage relay function
The OM-633 power consumption limiter is designed for au-
tomatic disconnection of the power supply of the electrical
installation circuit in case of exceeding the set value of power
consumed by the receivers in this circuit as well as for monito-
ring the power supply voltage of this receiver and protecting it
against the effects of voltage increase or decrease beyond the
set values.
»
Adjustable threshold of tripping power 1÷10 kW;
»
Protection against the drop of UL power supply voltage
(150÷210 V);
»
Protection against the rise of UL power supply voltage
(230÷260 V);
»
Counter of relay actuations with automatic disconnection
of system power supply after exceeding a set number of
actuations;
Purpose
Features
F&F Filipowski sp. j.
Konstantynowska 79/81, 95-200 Pabianice, POLAND
phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71
www.fif.com.pl; e-mail: [email protected]
Do not dispose of this device in the trash along with other waste!
According to the Law on Waste, electro coming from households free of char-
ge and can give any amount to up to that end point of collec� on, as well as
to store the occasion of the purchase of new equipment (in accordance with
the principle of old-for-new, regardless of brand). Electro thrown in the tra-
sh or abandoned in nature, pose a threat to the environment and human health.
Содержание OM-633
Страница 6: ... 6 Connection diagram ...