background image

Содержание LE-01MW

Страница 1: ...emote reading and config uration of the meter Compliance Purpose F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 23 83 48 42 227 09 71 www fif com pl e mail biuro fif com pl Donotdisposeofthisdeviceinthetrashalongwithotherwaste According to the Law on Waste electro coming from households free of charge and can give any amount to up to that end point of collec ...

Страница 2: ... days and weekends indication of network parameters compliance with MID RS 485 port Modbus RTU protocol backlit LCD display the possibility of a local reading of the indication of energy consumption also in the case of a power failure of the meter The LE 01MW meter precisely measures the amount of consu med electricity under the influence of flowing current and ap plied voltage Power consumption i...

Страница 3: ...ordance with the Modbus RTU standard via the RS 485 serial port The read out values of registers after conversion give results according to the indica tions on the indicator display Active energy consumed AE AE kWh Reactive energy AE kWh Phase voltage U V Phase current I A Frequency F Hz Active power P W Reactive power Q var Apparent power S VA Power factor cosϕ Description of measurement and conf...

Страница 4: ...he meter register The default meter address 1 The meter is marked with individual serial number allowing its unambiguous identification The marking is laser engraved and cannot be removed The meter has sealable input and output terminal covers to pre vent any attempts to bypass the meter Meter address Meter number Sealing ...

Страница 5: ... 5 Front panel ...

Страница 6: ... 6 1 LIN power input 3 LOUT power output N N wire neutral 23 RS 485 output A 24 RS 485 output GND 25 RS 485 output B Wiring diagram ...

Страница 7: ... display shows cyclically the following measured values The list of displayed parameters and the frequency of switching the displayed parameter can be parameterized via the RS 485 interface Data displayed on the LCD ...

Страница 8: ...cuit or single receiver to terminal 3 output phase L and to N 6 Connect terminals 23 24 and 25 to the RS 485 network Program for test reading of the counted energy value and for basic settings of the meter parameters Available at www fif com pl on the device s subpage For communication of the meter with the computer the USB CN USB 485 converter or any RS 485 USB standard is required installation 2...

Страница 9: ...0 2000 pulses kWh communication port RS 485 communication protocol Modbus RTU transmission parameters 1200 2400 4800 9600 bps parity NONE ODD EVEN stop bits 1 read out signalling red LED working temperature 25 55 C terminal 100 A 25 mm screw terminals RS 485 1 mm screw terminals tightening torque 0 4 Nm dimensions 1 module 18 mm mounting on TH 35 rail ingress protection IP51 _________________ fact...

Страница 10: ...clares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE and MID Declaration of Conformity along with the ref erences to the standards in relation to which conformity is de clared can be found www fif com pl on the product subpage Dimensions Warranty CE declaration ...

Страница 11: ...sure that all cables are connected correctly It is essential to observe the operating conditions of the meter supply voltage humidity temperature To avoid electric shock or damage to the meter turn off the power supply whenever the connection is changed Do not make any changes to the unit yourself Doing so can re sult in damage to or improper operation of the device which in turn can pose a threat...

Страница 12: ......

Отзывы: