J1, J2, J3 jumper configuration:
J1: switching on or off the chime in the door station
a)
jumper put on – audible chime
b)
jumper removed – chime off
J2: fit the cable in the video line depending on the number of monitors in the system:
a)
1 monitor: jumper put on + resistor
on the cables between video and ground
b)
2 monitors: jumpers in two monitors put on
c)
3 monitors: jumper removed in first monitor,
put on in monitors 2 and 3
d)
4 monitors: jumper removed in first
and second monitor, put on in 3 and 4
J3: switching on or off the backlight of the call button
and the signboard in KK-04 door station:
a)
jumper put on – backlight on
b)
jumper removed – backlight off
In case of door stations other than KK-04,
the jumper must be removed
.
1) audio-red
2) ground-blue
3) camera power supply-yellow
4) video-white
8) (+) of power supply-red
9) (-) of power supply-black
10)
connection to the control input of the door
automaton, it is a closing contact
of the NO relay (dry contact).
Do not connect voltages greater than 24 V,
the current should not exceed 150 mA
.
Dimensions: 282×135×23 mm
MK-06WF
Cursors
Menu exit
Menu
Door automaton control
connection
of the DC 14.5 V
power supply
connection
to the control input
of the door automaton