- 6 -
power supply
18÷24 V AC
21÷27 V DC
maximum load current (AC-1)
5 A*
frequency of microwaves radiation
5.8 GHz
radiation power
10 mW
detection field
360°
detection radius (adjustable)
for h= 2.5 m
1÷10 m
activation threshold (adjustable)
2÷2000 lx
switching time (adjustable)
5 s÷12 min.
activation delay
1 s
power consumption
0.9 W
terminal
1.0 mm² screw terminals
tightening torque
0.25 Nm
working temperature
-25÷50°C
dimensions
ø103, H= 44 mm
mounting surface
mounting height
2÷6 m
ingress protection
IP20
__________
* Load of a resistive nature [AC-1].
For loads of a different nature (e.g. LED lighting),
the maximum load current may be significantly
lower.
More information:
www.fif.com.pl/en/content/24-wskazowki
Technical data
Содержание DRM-02 24 V
Страница 5: ...5 3 terminal connection 4 terminal connection Wiring diagram...
Страница 8: ......