background image

- 4 -

1. Disconnect the power supply.

2. Install the sensor in a selected place.

3. Connect the wires according to the wiring diagram.

4. Set the area of the detection field, the sensitivity of the twili-

ght sensor and the activation time.

After activation the motion sensor is inactive for the first 

10 seconds.

Mounting

Description of device

Содержание DRM-01 24 V

Страница 1: ...n during the day When motion is detected after dusk the lighting will be switched on and will remain on as long as motion is detected When the movement stops the light rema ins switched on for a speci...

Страница 2: ...temperature The detection range the brightness level that activates the sensor and the time of operation back up are set using the knobs described later in this manual The sensor is designed for indoo...

Страница 3: ...e towards the sun Detection area SENS The detection radius of the sensor can be adjusted from 1 m to 10 m parameters given for a sensor mounted at a height of 2 5 m Turning the knob clockwise max incr...

Страница 4: ...ed place 3 Connect the wires according to the wiring diagram 4 Set the area of the detection field the sensitivity of the twili ght sensor and the activation time After activation the motion sensor is...

Страница 5: ...5 3 terminal connection 4 terminal connection Wiring diagram...

Страница 6: ...vation threshold adjustable 2 2000 lx switching time adjustable 5 s 12 min activation delay 1 s power consumption 0 9 W terminal 1 0 mm screw terminals tightening torque 0 25 Nm working temperature 25...

Страница 7: ...that the device is in conformity with the essential requirements of The Directive 2014 53 EU of the European Parliament and of the Council of 16 April 2014 on the harmonisation of the laws of the Mem...

Страница 8: ......

Отзывы: