background image

- 5 -

1. Disconnect the power supply.

2. Make a mounting hole in the substrate/fit a ø60 mm flush-mo-

unted box.

3. Undermine the hooks and remove the external cover of the 

sensor.

4. Connect the wires as shown in the diagram.

5. Insert the main body into the mounting hole/flush-mounted 

box and screw in place.

6. Set the area of the detection field, the sensitivity of the twili-

ght automatic control unit and the switch-on time.

7. Assemble the external cover of the sensor.

8. Switch on the power supply to the sensor.

The sensor is inactive for the first 30 seconds after the 

power supply is switched on. During this time, the PIR 

system warms up.

Do not install the sensor in the immediate vicinity of he-

ating, air-conditioning and lighting devices.

If the motion sensor is installed too close to the switched 

light source, the system may be activated, which means 

that the sensor will automatically switch on and off the 

light source. It is necessary to move the sensor to an ap-

propriate distance away from the light source.

Mounting

Содержание DR-08

Страница 1: ...t disappearance in the course of time measurement starts the support time from the beginning The specific of operation al lows using the DR 08 as a presence sensor The motion sensor is equipped with a...

Страница 2: ...he range of 3 s 9 min Changes in temperature can affect the motion detec tion The motion sensor can work indoors and outdoors in places where it is not exposed to direct rain or snowfall and to the po...

Страница 3: ...within the range of 3 sec to 9 min Turning the control knob right increases the switching on time turning left reduces the switching on time The sensitivity of the twilight sensor The sensitivity of...

Страница 4: ...4 Installation height of the sensor Detection angle range of the sensor Detection area ceiling mounting...

Страница 5: ...on time 7 Assemble the external cover of the sensor 8 Switch on the power supply to the sensor The sensor is inactive for the first 30 seconds after the power supply is switched on During this time th...

Страница 6: ...6 Wiring diagram Dimensions...

Страница 7: ...nsumption standby 0 10 W on 0 45 W terminal 1 0 mm screw terminals tightening torque 0 25 Nm working temperature 10 40 C dimensions external 105 mm H 71 5 mm groove 50 mm H 43 mm mounting hole 51 mm s...

Страница 8: ...declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration...

Отзывы: