Mounting the pipe chain drive (optional)
The chain drive is suitable for 1-inch pipe.
2.6
Mounting the CE cover
Placement of the CE cover is mandatory if the iM.60 is installed within reach (lower than 2.5 m above the
subsurface) of humans or animals.
2.7
Connecting the iM.60
You may connect to the iM.60 as an I/O network module or as a traditional terminal.
Make sure that the iM.60 is well and properly grounded according to the guidelines.
Install the cables in such a way that they cannot become damaged and so that they can easily be
replaced in the event of malfunction. Limit the length of the cables much as possible.
Low-voltage and high-voltage wires may not be placed parallel to each other but may cross each other.
When using metal ducts, Fancom advises grounding the ducts at the ends and at as many other places
as possible.