Before you can use the eYeGrow the correct IP addresses have to be scanned: 

1.

Use an IP scanner to detect the cameras

. A reccomended software is Advanced IP Scanner, and can be

found at this link: 

https://www.advanced-ip-scanner.com/

2.

Check the MAC Address on the eYeGrow camera box (00:19:B8:02:xx:xx) and match the IP address to the
MAC Address.

3.

Go to the internet browser and enter the IP address of the camera. The browser will open and shows the
overview screen:

RJ45 ethernet cable (eYeGrow)

 

1. Orange/white

2. Orange

3. Green/white

4. Blue

5. Blue/white

6. Green

7. Brown/white

8. Brown

Ethernet in from

5-port switch or

previous eYeGrow

24V in

from 5-port 

switch

+

-

Содержание eYeGrow

Страница 1: ...eYeGrow Pig group weigher MANUAL STU4004...

Страница 2: ...e original English version of this manual produced by PigTek For the latest information about product installation and operation please contact the customer service dept and or the technical service d...

Страница 3: ...ged products or goods costs of transportation lost sales lost orders lost income increased overhead labor and incidental costs and operational inefficiencies Some jurisdictions prohibit limitations on...

Страница 4: ...ling the eYeGrow 2 3 1 Mount the eYeGrow 2 3 2 Connect the eYeGrow and Switch 5 port 4 3 3 Scan the IP adresses of the eYeGrow 5 4 Using the eYeGrow 6 4 1 Sensor Settings 6 4 2 Working with the overvi...

Страница 5: ...and animals Example of a practical application of the described functionality Calculation example Before installing and commissioning the eYeGrow read the safety instructions provisions and conditions...

Страница 6: ...d 7 1 2 ft 2 3m above the pen Animals are weighed from 88 18 lbs 40 kilograms The software starts showing measurements between 88 18 and 110 23 lbs 40 and 50 kilograms Install the eYeGrow as follows 1...

Страница 7: ...ow Example configurations are shown below NOTES Kits can be assembled with or without the adjusting flats and at any desired angle from 0 to 90 degrees to help you achieve the optimal 7 55 ft height f...

Страница 8: ...nd connect 24V DC cables to the next eYeGrow box 2 Open the Switch 5 port and connect the 24V DC cable to the first eYeGrow box 3 Connect each eYeGrow box with an ethernet cable to the Switch 5 port 4...

Страница 9: ...m 2 Check the MAC Address on the eYeGrow camera box 00 19 B8 02 xx xx and match the IP address to the MAC Address 3 Go to the internet browser and enter the IP address of the camera The browser will o...

Страница 10: ...average growth yesterday Readings today Readout of the number of readings today Uniformity Readout of the percentage how many pigs meets the average weight 10 10 Standard deviation Readout of the sta...

Страница 11: ...measured data from the start of the rearing batch Update table and graph Set the From and To date and click Update to update the data in the graph and table Download graph Open the Chart context menu...

Страница 12: ...sor to restart the sensor Cleaning of dust fly faeces has been undertaken once per rearing batch using a streak free screen cleaner and microfibre cloth Use the correct cleaning products to avoid scra...

Страница 13: ...ation speed Max 100 Mb Ethernet wired Cat 5 max 100 meter Housing Plastic housing ABS UL94 V 0 Protection class IP54 Dimensions l w h 300 240 140mm Weight unpacked 2 4kg Ambient climate Operating temp...

Страница 14: ...provisions of the 1 Low voltage directive 2014 35 EU according to NEN EN IEC 61010 1 2010 2 EMC directive 2014 30 EU Emission according to NEN EN IEC 61000 6 3 2007 Immunity according to NEN EN IEC 61...

Отзывы: