Fancom 747
6. Settings
18
Curve
In houses with heavier animals, a high occupancy and mixed males and
females, it is advisable to enter the upper and lower limits in the computer
via a curve. The heavier the animals become and the higher the
occupancy, the higher the lower limit should be. The lighter, female
animals will be proportionally more frequently on the scales. By setting
Lower%
lower, the computer will refuse to accept a number of the lighter
weights. This will not influence the weight spread.
1.
Press
Acceptation settings,
then 3×.
The following text will appear on the display:
2.
At
Curve
enter whether the computer should take the lower and
upper limit from the curve.
3.
Use to select the bending point (max. 10 bending points).
4.
Enter the day number and the lower and upper limit corresponding to
this bending point.
5.
Make these settings for the other bending points in this curve.
Example :
Lower limit (%)
30%
Upper limit (%)
30%
Acceptation weight (calculated)
1000g
The computer calculates the acceptation lower
and upper limit:
Acc. lower limit
1000g - 30% = 700g
Acc. upper limit
1000g + 30% = 1300g
Uniformity calculation
Curve YES
Day_1 Lower% Upper%
1 30 30
3×