Fanaway MYA Скачать руководство пользователя страница 2

  Fanaway Mya Installation Instructions 

 

 

2  | 

P a g e                                       M Y A - M E N A R D S   V e r s i o n 1 . 0   1 / 2 0 2 1  

                                     

 

 

 

 

THANK YOU FOR PURCHASING 

 
Thank you for purchasing this quality Fanaway product. To ensure correct function and safety, please 
read and follow all instructions before assembly, installation and use of this ceiling fan.

 

Please keep 

instructions for future reference.

 

 

SAFETY PRECAUTIONS 

Read and Save These Instructions 

This product conforms to UL standard 507. 

1. 

WARNING -To avoid possible electrical shock, before installing or servicing your fan, disconnect the 
power by turning off the circuit breaker of the fuse box to the outlet box. 

2. 

WARNING - To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked 
“acceptable for fan support of 70 lbs (31.8 kg) or more” and use the mounting screws provided with 
the outlet box and/or support directly from building structure. Most outlet boxes commonly used for 
the  support  of  luminares  may  not  be  acceptable  for  fan  support  and  may  need  to  be  replaced. 
Consult a qualified electrician if in doubt. 

3.  Suitable for use with solid-state speed controls 

4. 

WARNING - To reduce the risk of personal injury, do not bend the blade brackets when installing the 
blade brackets balancing the blades, or cleaning the fan. Do not insert foreign objects in between 
rotating fan blades. 

5. 

CAUTIONS - All wiring  must be in accordance with the National  Electrical Code (ANSI/NFPA 70) 
and  local  electrical  codes.  Electrical  installation  should  be  performed  by  a  qualified  licensed 
electrician. 

6. 

To reduce the risk of injury to person, the fan must be mounted with a minimum of 7 feet clearance 
from the bottom edge of the blades to the floor. 

7. 

After  marking  electrical  connections,  spliced  conductors  should  be  turned  upward  and  pushed 
carefully up into the outlet box. The wires should be spread apart with the grounded conductor and 
the equipment-grounding conductor on one side of the outlet box. 

8. 

This  equipment  has  been tested  and  found to comply  with  the  limits for  a Class B  digital  device, 
pursuant  to  part  15  of  the  FCC  rules.  These  limits  are  to  provide  reasonable  protection  against 
harmful  interference  in  a  residential  installation. This  equipment  generates,  uses  and can  radiate 
radio frequency energy and if not installed and used in accordance with the instructions may cause 
harmful interference to radio communications. 

9.  CAUTION - To reduce the risk of electric shock, disconnect the electrical supply circuit to the fan 

before installing light kit. 

10. The light kit plate weight is 1.56kg. 

Содержание MYA

Страница 1: ...pport beaconlighting us www beaconlighting us US Patent 8317470 8807938 8790085 9255584 8851841 V1 0 1 2021 FANAWAY MYA CEILING FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ...

Страница 2: ...d the blade brackets when installing the blade brackets balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades 5 CAUTIONS All wiring must be in accordanc...

Страница 3: ...purchase for inspection or replacement Check whether the ceiling fan has been damaged during transport Do not operate install any product which appears damaged in any way Return the complete product...

Страница 4: ...he weight of the moving fan at least 70 lbs Do not use a plastic outlet box Figures 2 3 below show different ways to mount the outlet box A not included NOTE The ceiling fan must be installed in a loc...

Страница 5: ...center of the ceiling mounting bracket D Install the ceiling mounting bracket D on the outlet box B with the mounting screws F provided with the outlet box and washers E provided with fan Fig 5 HANGIN...

Страница 6: ...s shown in Fig 7 2 Connect the household neutral supply wire white to the receiver input wire white AC IN N 3 Connect the household ground wire to the fan mounting bracket ground wire green and fan bo...

Страница 7: ...assembly up to the mounting bracket and let the L shape slot on the hanging canopy 3 go through the two canopy screws with star washer 2 Fig 8b Turn the hanging canopy 3 until it locks in place at the...

Страница 8: ...e slots 2 3 Secure screw 2 to the light kit plate Tighten all three screws Do not over tighten 4 Connect the quick connector of fan assembly to the quick connector of the light kit assembly Fig 9 5 Lo...

Страница 9: ...up the transmitter by the holder USING YOUR CEILING FAN SETTING DIP SWITCHES When two or more fans are located near each other you may desire to have the receiver transmitter for each fan set to a dif...

Страница 10: ...PERATING THE REMOTE Before you start using the remote take the time to read through this section and get familiar with the buttons and function of each button LED Indicator The red LED indicator on th...

Страница 11: ...to move during operation due to the fact that they are mounted on a rubber grommet If the fan was mounted rigidly to the ceiling it would cause excessive vibration Movement of a few centimetres is qu...

Страница 12: ...ibility of an electrical shock 3 Ensure that the fan does not come in contact with any organic solvents or cleaners 4 To clean the fan blade wipe with only a damp clean cloth with NO organic solvents...

Страница 13: ...ificado 3 Apto para utilizarse con controles de velocidad de estado s lido 4 ADVERTENCIA Para disminuir el riesgo de que se produzcan lesiones personales no doble los soportes de las aspas al instalar...

Страница 14: ...do con las instrucciones puede causar interferencia da ina con las comunicaciones de radio 9 PRECAUCI N Para reducir el riesgo de descarga el ctrica desconecte el circuito de suministro el ctrico del...

Страница 15: ...emplacen Compruebe si el ventilador de techo se da durante el transporte No ponga en funcionamiento ni instale ning n producto que presente cualquier tipo de da o Regrese el producto completo al lugar...

Страница 16: ...g de peso No use una caja de salida de pl stico Las figuras 2 3 siguientes muestran tres tipos distintos de armado de la caja de salida A no incluida NOTA El ventilador de techo debe instalarse en un...

Страница 17: ...armado en el techo D Instale el soporte de armado en el techo D en la caja de salida B con los tornillos de armado F suministrados con la caja de salida y las arandelas E incluidas con el ventilador F...

Страница 18: ...ecte el cable de tierra de la casa al cable de tierra del soporte del ventilador verde y al cable de tierra de la carcasa del ventilador 4 Conecte el cable de salida del receptor negro AL MOTOR VIVO a...

Страница 19: ...asta el soporte de armado y deje que la ranura en forma de L del flor n 3 pase por los dos tornillos del flor n con una arandela de estrella 2 Fig 8b Gire el flor n 3 hasta que encaje en su lugar en l...

Страница 20: ...o 2 al soporte del conjunto de luces Apriete los tres tornillos No los apriete en exceso 4 Conecte el conector r pido del conjunto del ventilador al conector r pido del conjunto del juego de luces Fig...

Страница 21: ...exceda la potencia m xima nominal Fig 11 9 Para terminar instale la pantalla de la l mpara en la placa del juego de luces gir ndola en sentido horario INSTALACI N DEL SOPORTE DEL TRANSMISOR Fig 12 Ins...

Страница 22: ...uebe que los interruptores DIP del transmisor y receptor remotos se corresponden Si no se corresponden el transmisor no funcionar Fig 15 INSTALACI N DE LA BATER A DEL CONTROL REMOTO El control remoto...

Страница 23: ...de la luz El control remoto tiene funci n de memoria Si el ventilador o la luz se apagan mediante el interruptor de aislamiento lo memorizar y restablecer el ltimo estado al encenderlo de nuevo FUNCI...

Страница 24: ...periodo de ajuste de 24 horas y la mayor a de los ruidos asociados con el nuevo ventilador desaparecer n en dicho periodo de tiempo Todos los motores el ctricos producen un cierto ruido Tenga en cuent...

Страница 25: ...eto lb C F VENTILADOR BI 36 MYA E26 XXX Extra alta 120 0 46 54 92W 285 3042 43 55 4 17 2 3 05 Media alta 120 0 34 27 35W 219 2146 70 78 49 17 2 3 05 Baja 120 0 23 12 48W 170 1332 89 106 8 17 2 3 05 Es...

Отзывы: