background image

 

 

 

 
Installation of the carbon filter 

  

FIG.11 

 

1. 

Remove the filter frame from the 

unit. 

2. 

Separate the filter fixer from the filter 

frame. 

3. 

Remove the active carbon filter from 

its plastic bag. 

4. 

Insert the active carbon filter into the 

filter frame. 

5. 

Fix the filter by reassembling the 

fixer onto the filter frame. 

6. 

Re-fit the filter frame inside the unit.

 

 

FIG.12 

 

 
 

Содержание TCB-8063HI series

Страница 1: ...PORTABLE AIR CONDITIONER INSTRUCTION MANUAL for TCB 8063HI series Read and retain these instructions for future reference ...

Страница 2: ...ed 3 Timer 1 24 hours Working temperature Cooling 18 32o C Heating 7 25o C Exhaust pipe Ø 142 x 1500mm Net weight 27 5 kg Dimension WxDxH 420 x 405 x 790 mm REMARK 1 Measuring condition for above is as per EN 14511 Cooling DB 35 C WB 24 C Heating DB 20 C WB 12 C DB temperature of dry bulb room temperature WB temperature of wet bulb relative humidity 2 Test condition for data in our rating label is...

Страница 3: ...f the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with appliance ELECTRICAL SAFETY For indoor use only Switch off and unplug when not in use Do not use in humid or wet environments Fig 3 Do not pull the unit along by the cord IF THE SUPPLY CORD IS DAMAGED IT MUST BE REPLACED BY AN ELECTRICIAN OR SIMILARLY QUALIFIED PERSON TO AVOI...

Страница 4: ...int Accessories FIG 7 13 Exhaust hose 14 Adaptor for insertion over hose and into window spacer or into hole in the wall window 15 Cover for adaptor 16 Foam strip for filling the open window space 17 Foam strip for filling the open window space 18 Foam strip for filling the open window space and with hole for connection to exhaust hose 19 Drain tube for continuous drainage 20 Active carbon filter ...

Страница 5: ...window spacer and slide window across so that spacer is held securely This technique may also be used for sash windows Note Take care to maintain protection against intruders 2 Using the adaptor FIG 10 FIG 9 Cut a 152mm diameter hole in the wall or window Feed exhaust hose through the window or wall and attach the threaded adaptor from the outside as shown When not in use plug the hole with the co...

Страница 6: ...e expelled moist air to build up causing the unit to overheat and shut down The hose may be extended from 300mm to 1500mm but for maximum efficiency use the shortest length possible WARNING The length of the exhaust pipe is specially designed according to the specification of this product Do not replace or prolong it with your own private hose as this could cause the unit to mal function ...

Страница 7: ...nit 2 Separate the filter fixer from the filter frame 3 Remove the active carbon filter from its plastic bag 4 Insert the active carbon filter into the filter frame 5 Fix the filter by reassembling the fixer onto the filter frame 6 Re fit the filter frame inside the unit FIG 12 ...

Страница 8: ...or j Sleep function operation indicator k Ionizer indicator optional l Water Full indicator Turning ON OFF Adjust the louvers to desired angle and position Press ON OFF button the unit will start to work If the ambient temperature is higher than 23 o C the unit will work in cool mode higher than 20oC but below or equal to 23oC the unit will work in ventilation model below 20 o C the unit will work...

Страница 9: ...hour s you set as you press TIMER button If the timer button is not pressed the unit will work continuously 2 By pressing the timer but without turning on the other functions you can PRE SET the time for the machine to work For example if you press the timer to 2 the unit will work automatically after 2 hours Sleep function 1 In cooling mode by pressing the SLEEP button the set temperature will in...

Страница 10: ...To start Ionizer button please press Ionizer button This function can clean the air improve the air quality Self diagnosis This machine is equipped with self diagnosis function If something is wrong in the machine the LED will show the word E1 or E2 As this time please call your service centre EFFICIENCY BOOSTING This unit is equipped with energy efficiency boosting function by adding the water to...

Страница 11: ...ed level the cooling will return to work 3 On the contrary the heating will switch off if the ambient temperature is higher than the set one still the ventilation keeps working on the set level As the ambient temperature drops below the selected level the heating will return to work 4 This machine is equipped with ANTI FROST function While using the heating function during low temperature sometime...

Страница 12: ...Remove the drain knob rubber plug from the drain hole and allow the water to drain out 4 When the container is almost full replace the rubber plug in the drain hole and empty the water tray 5 Repeat until the unit is emptied 6 Replace the rubber plug and tighten the drain knob firmly 7 Switch on the unit the full water or compressor operating indicator should not be flashing FIG 16 If you wish to ...

Страница 13: ...be OD 18mm Extended drain tube OD 18mm Original drain tube FIG 19 Special caution for heating function While using the heating function please note 1 Install the exhaust pipe well in order to exhaust the cool air to outdoor Please refer to the instruction manual for installation method 2 Fix the drainage to be continuous one i e drain the water by water tube 3 Working range for heating function is...

Страница 14: ...aning the filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water no hotter than 40o C Dry thoroughly before replacing Notice Never operate the unit without the filters End of season storage Drain any water in the unit before completely operating the unit on ventilation only mode for a few hours to thoroughl...

Страница 15: ...many people in the room Is there something in the room producing lots of heat The machine seems to do nothing Is the filter dusty contaminated Is the air intake or output blocked up Is the room temperature below your selected temperature Too noisy Is the machine positioned unevenly so as to create vibration Is the floor underneath the machine uneven The compressor doesn t run Is so it is possible ...