Leveling Accuracy Adjustment
Prerequisites for ensuring leveling accuracy
1
Accurate leveling must first ensure that the installation position of the door sensor and the magnetic
isolation plate is very accurate, that is, it is required to be installed in the elevator:
•
The length of the magnetic plate of each door must be accurate and consistent;
•
The bracket must be firm.
The installation position of the magnetic isolation board must be very accurate. When the car is in the flat
position, the center point of the magnetic isolation board coincides with the center point of the distance
between the two door sensor, otherwise the leveling point of the station will appear.
Move, that is, upper and lower are higher than the flat point or lower than the flat point.
2
If a magnetic induction switch is used, it should be ensured that the magnetic isolation plate is inserted
deeply enough during installation, otherwise it will affect the operation time of the induction switch,
resulting in the phenomenon of high and low level in the leveling layer of the landing.
3
In order to ensure the leveling, the system also requires the elevator to have a short crawl before parking.
•
Check the elevator feedback speed through D01.13 to determine if there is crawling speed when parking.
4
In the actual adjustment, you should first adjust an intermediate layer until it is leveled. Then based on this
parameter, adjust the other layers.
5
By adjusting the speed loop ratio of the F08 group and adjusting the integral gain, it should be ensured that
the parking position is repetitive when the elevator is parked from the up and down to the middle floor.
Parameters
Range
Value
F03.00
Acc.
0.020 - 9.999
0.700m/s
2
F03.01
Rapid Acc. at beginning
0.020 - 9.999
0.350m/s
3
F03.02
Rapid Acc. at end
0.020 - 9.999
0.600m/s
3
F03.03
Dec.
0.020 - 9.999
0.700m/s
2
F03.04
Rapid Dec. at beginning
0.020 - 9.999
0.600m/s
3
F03.05
Rapid Dec. at end
0.020 - 9.999
0.350m/s
3
F03.13
Rapid Dec. at stop
0.020 - 9.999
0.350m/s
3
Содержание MONT72 Series
Страница 1: ...V1 0 2018 09 MONT72 Series Elevator Controller User Manual MONT72 Series Elevator Controller ...
Страница 3: ...Version and Revision Records Version time 2018 9 Version V1 0 Chapter Content V1 0 issue ...
Страница 7: ......
Страница 9: ......
Страница 15: ......
Страница 43: ......
Страница 81: ......
Страница 99: ......