F02: Start & Stop Parameters
Ref. Code
Function Description
Setting Range [Default]
F02.00
Start delay time
0.000 - 4.999 [0.000s]
When MONT72 receives the run command, it will wait for the delay time set by F02.00 and then start running.
•
When controlled by keypad (F00.05 = 0), F02.00 is invalid.
F02.01
Brake open delay time
0.000 - 4.999 [0.000s]
Defines the time from zero-speed running to output brake-open command.
•
F02.01 enables MONT72 to enter running status before the brake open, so as to alleviate the impact at
start.
F02.02
Retention time of start zero-speed
0.000 - 4.999 [0.500s]
Defines the retention time from brake-open to output with speed. During the retention time, the motor has
output torque, which makes more comfortable.
•
F06.00 = 4 (no weighing auto-compensation is used), the value of F02.02 should exceed 0.5s.
F02.03
Start speed
0.000 - 0.400 [0.000m/s]
Defines the initial speed required for starting the controller.
•
The start speed, when properly set, can minimize the start jerk.
F02.04
Retention time of start speed
0.000 - 4.999 [0.000s]
Defines the time in which MONT72 runs at start speed (F02.03).
F02.05
Brake close delay time
0.000 - 4.999 [0.200s]
Defines the time interval from zero-speed running to output brake-closed command.
F02.06
Retention time of stop zero-speed
0.000 - 4.999 [0.300s]
Defines the time during which the motor runs at zero-speed and has output torgue at stop, which makes
more comfortable.
F02.07
Contactor close delay time
0.000 - 4.999 [0.000s]
Defines the running contactor delay release time after the run command is revoked.
F02.08
Start ramp time
0.000 - 2.000 [0.000s]
Defines the time that elevator takes to accelerate from zero to the rated speed (F00.02).
•
F02.08 = 0, the elevator starts from start speed directly.
Atzero-speed running
F02.08
F02.00 F02.01
F02.02
F02.04
F02.03
F00.02
F02.05
F02.06
F02.07
Speed
Time
Brake
Controller is in running
Contactor output
Run command
Objective speed
0
6
Содержание MONT72 Series
Страница 1: ...V1 0 2018 09 MONT72 Series Elevator Controller User Manual MONT72 Series Elevator Controller ...
Страница 3: ...Version and Revision Records Version time 2018 9 Version V1 0 Chapter Content V1 0 issue ...
Страница 7: ......
Страница 9: ......
Страница 15: ......
Страница 43: ......
Страница 81: ......
Страница 99: ......