1.  Installation 

Find a suitable place where to mount the GSM gateway following these guide lines: 

  Make sure the GSM coverage is good before the GSM gateway is mounted.  

Place the Gateway near a window if possible. 

  Make sure the LEDs on both sides are visible. 

  Make sure there is a power source, 230 VAC or 12-24 VDC reachable.  

  Connect the antenna. Place the antenna as far away from the Gateway as possible. 

The antenna can be placed on any magnetic metal surface.  

  Connect the Fältcom ECII Flex to the Phone input.  

Use the 122033 Modular cable and the terminal connector if required. 

1.1  PIN code 

Note: The GSM gateway must always be turned off before inserting or removing the SIM card. Please 
see section “Turn off the GSM Gateway” before removing a SIM card. 

Choose whether the PIN code should be activated or deactivated. 

1.1.1  PIN code deactivated 

Use a mobile phone or other equipment to deactivate the PIN code on the SIM card.  

1.1.2  PIN code activated 

The PIN code must be set to “1234”. Use a mobile phone or other equipment to set the PIN code to 
“1234”. 

At startup the GSM Gateway will automatically change the PIN code to a random 4-digit code to 
prevent misusage of the SIM card. If the SIM card is to be used later; use the PUK code to unlock the 
SIM. 

1.2  Startup 

Start the GSM Gateway:  

 

Gently insert the SIM-card into the GSM unit as shown in the pictures above. 

Make sure the cut corner of the SIM is on the left side and the connector pads facing down. 

  Connect the power cable.  

The startup might take up to 30 seconds before the GSM Gateway has established a 
connection with the GSM network. For information on how to understand the LED indications, 
please see section 2 and section 3 below.  

1.3  Turn off the GSM Gateway 

1.  Remove the DC power connector from the GSM Gateway. 
2.  Push the RESET button with a short push to turn the unit off. 

1.4  Change SIM card 

If the SIM-card needs to be changed; the new SIM-card must have “1234” as PIN-codes or have the 
PIN-code deactivated.  

1.  Turn off the GSM Gateway; remove the DC power connector from the GSM Gateway. 
2.  Push the RESET button with a short push to turn the unit off. 
3.  Remove the old SIM and insert the new SIM as shown in the pictures above.  
4.  Connect the power cable.  

Содержание 252236

Страница 1: ...GSM Gateway 252236 User Manual Art No 162236M V3 21D 2016 02 18...

Страница 2: ...t alarm 8 5 SMS functionality 9 5 1 Low battery voltage indication 9 5 2 Dial tone battery alarm Dial tone 2 11 5 3 Status 12 5 4 Reset 13 5 5 Ask for the current Gain 13 5 6 Change the Gain 13 6 Upgr...

Страница 3: ...G The product complies with the following standards norms EN 55022 2006 and A1 2007 EN 55024 1998 and A1 2001 and A2 2003 EN 60950 2006 and ETSI EN 301 511 Ume Sweden January 2013 Mikael L ngstr m CEO...

Страница 4: ...the lift phone F ltcom ECII Flex and Power SIM Lift phone F ltcom ECII Flex in LIFT CAR TELE PHONE ANT Power Supply 12 24 VDC 230 VAC OR Battery ANTENNA SIM PIN code Activated or deactivated PIN code...

Страница 5: ...se a mobile phone or other equipment to set the PIN code to 1234 At startup the GSM Gateway will automatically change the PIN code to a random 4 digit code to prevent misusage of the SIM card If the S...

Страница 6: ...nformation please see section 5 3 LED Indicators LED Status Indicates PWR STAT 1000 ms ON 1000 ms OFF Normal status 100 ms ON 1500 ms OFF Backup power in use PHONE Red LED OFF Phone device is On hook...

Страница 7: ...ngth Green LED S1 S2 Signal strength OFF OFF Bad ON OFF Good default 15 83 dBm ON ON Very good default 25 63 dBm Flash OFF Good Backup power in use Flash Flash Very good Backup power in use LED levels...

Страница 8: ...by a change of the normal dial tone see section 5 2 below The first battery test is made after 48 hours and the following every 24 hour During a battery test a load is connected to the battery and th...

Страница 9: ...t changed The GSM will acknowledge a correct programming by returning a SMS In the example below the battery alarm level is changed to 4 0 V 4000 mV In this example a Low battery voltage indication wi...

Страница 10: ...ge level the following is sent from the GSM Gateway Both functions described above are switched off by sending the following to the GSM Gateway The Battery replaced SMS Bares function described above...

Страница 11: ...taken off hook To deactivate the Dial tone battery alarm dial tone 2 send the SMS below to the GSM Gateway The GSM will acknowledge a correct programming by returning a SMS To reactivate the dial ton...

Страница 12: ...l strength signal strength in dBm S H L Highest signal during last 24h lowest signal during last 24h since last restart UT Uptime counter presented in days hours and minutes LC Last called number not...

Страница 13: ...word Gain The default Access code is 1111 and can be changed using the F ltcom Manager SW If the SMS is correct the Gateway will return the Gain settings Description table of the gain SMS Parameter De...

Страница 14: ...rameter for signals from alarm receiver to Flex 4 20 POTS GSM Gain parameter for signals from Flex to the alarm receiver 3 20 If the received parameters are outside the range the Gateway will set the...

Страница 15: ...local distributor Use a standard USB mini USB cable to connect the GSM Gateway to the PC Install the F ltcom Manager tool on your PC Connect the GSM Gateway to the PC using a standard USB mini B USB...

Страница 16: ...y F ltcom or your local distributor Note The FW file always has the file extension bin e g gatewayFW bin Click on Update During the update you can follow the progress in the status bar Note Be careful...

Страница 17: ...able the Battery fault alarm but still charge the battery If the lift has a battery backup system the battery in the Gateway can be removed uncheck the Mounted battery box to disable all battery charg...

Страница 18: ...not improve try positive values If the receiver has trouble receiving and deciphers DTMF sent by the emergency alarm try adjusting the POTS PHONE to GSM 6 2 6 POTS1 power saving Note Do not use this...

Страница 19: ...ass IP 20 External power 10 28 VDC Power consumption At rest 12V 180mA 24V 95mA Ongoing call 12V 330mA 24V 160mA Battery type NiMH 4 8V 1250mAh Battery power consumption At rest 120 mA Ongoing call 30...