19
ENGLISH
OPERATION
WHEN TO TURN ON THE HOOD?
Switch on the hood at least one minute before starting to cook to direct fumes
and vapours towards the suction surface.
After cooking, leave the hood operating until complete extraction of all vapours
and odours. By means of the Timer function, it is possible to set auto switch-off
function which will allow the hood to turn off automatically after 15 minutes of
operation.
WHICH SPEED IS TO BE SELECTED?
1st speed:
maintains the circulation of clean air with low electricity consumption.
2nd speed:
normal conditions of use.
3rd speed:
presence of strong odours and vapours.
4th speed:
rapid disposal of odours and vapours.
WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?
The metal filters must be cleaned every 30 hours of operation.
For further details see the
“MAINTENANCE”
chap.
TOUCH PUSHBUTTON PANEL
ON/OFF (Blue led steady on)
Motor on/off and Speed 1
ON/OFF (blue led flashing)
If pressed for more than 3 seconds, it activates the 24h cycle (1h ON
-> 3h
OFF -> 1h ON)
the function deactivates if:
- The motor turns off (key
)
- After 24h
Speed 2 activation
Speed 3 activation
Speed 4 activation for a few minutes only
Light on/off
TIMER
(Red LED flashing)
Auto switch-off after 15 min.
The function deactivates (red LED off ) if:
- The motor turns off (key
).
- The speed is changed.
FILTER ALARM
(red LED steady on)
Anti-grease filter maintenance after approximately 30 hours of op-
eration.
Press the meter for 3 seconds to reset.
If the pushbutton panel is completely inactive, before contacting the
Technical assistance service, disconnect power temporarily to the ap-
pliance (about 5“), possibly by acting on the main switch, to restore
normal operation.
If this measure has no effect, contact the Technical assistance service.
FUMES DISCHARGE
EXTERNAL EXHAUST HOOD (SUCTION)
In this version the fumes and vapours are discharged outside
through the exhaust pipe.
To this end, the hood outlet fitting must be connected via a
pipe, to an external output.
The outlet pipe must have:
• a diameter not less than that of the hood fitting.
• a slight slope downwards (drop) in the horizontal sections to prevent conden-
sation from flowing back into the motor.
• the minimum required number of bends.
• the minimum required length to avoid vibrations and reduce the suction per-
formance of the hood.
You are required to insulate the pipes if it passes through cold environments.
In the presence of motors with 800m3/h or higher, a check valve is present to
prevent external air flowing back.
Deviation for Germany:
when the kitchen hood is used at the same time as appliances that are powered by
energy other than electricity, the negative pressure in the room must not exceed 4 Pa
(4 x 10-5 bar).
HOOD WITH INTERNAL RECIRCULATION (FILTERING)
In this model, the air passes through an optional filter unit in
the ceiling to be purified and recycled in the environment.
In this version the check valve must not be assembled: remove it if it is
on the air outlet fitting of the motor.
ASSEMBLY INSTRUCTIONS
only intended for qualified personnel
The hood can be installed in various configurations.
The generic assembly steps apply to all installations; for each case,
follow the specific steps provided for the required installation.
Содержание Luce LUCE90E3BL
Страница 2: ...2 46 600 max 572 320 318 255 121 258 max 1218 898 596 8 mm LUCE ISOLA 32 KG 800 m3 h...
Страница 33: ...33 2 13 AS NZS 60335 2 31 2013 A4 2020...
Страница 34: ...34 8 1 5 65 25 6 EN60335 2 31...
Страница 35: ...35 70 C III 800 3 4 4 x 10 5 15 I II III IV 30 1 3 24 1 3 1 24h 2 3 4 3 15 30 3 5...
Страница 36: ...36 RAEE RAEE 15 Magic Steel 1 55 C 9...
Страница 65: ...65 NOTE NOTES...
Страница 66: ...66 NOTE NOTES...
Страница 67: ...67 NOTE NOTES...