ELECTRICAL CONNECTION

(Intended only for qualiied personnel)

Disconnect the equipment from electrical mains power supply before carry-
ing out any operations on the hood.
Ensure that the wires inside the hood are not disconnected or cut:
in the event of damage, contact your nearest Servicing Department.

Refer to qualiied personnel for electrical connections.
Connection must be carried out in compliance with the provisions of law in force.

Before connecting the hood to the electrical mains power supply, check that:
•  voltage supply corresponds with what is reported on the data plate located inside the 

hood;

•  the electrical system is compliant and can withstand the load (see the technical specii-

cations located inside the hood);

•  the power supply plug and cable do not come into contact with temperatures exceed-

ing 158°F (70 °C);

•  the power supply system is efectively and properly connected to earth in compliance 

with regulations in force;

•  the socket used to connect the hood is within reach.

In case of:
•  devices itted with cables without a plug: the type of plug to use is a ''standardised'' one. 

The wires must be connected as follows: yellow-green for grounding, blue for neutral 
and brown for the live. The plug must be connected to an adequate safety socket.

•  ixed equipment not provided with a power supply cable and plug, or any other device 

that ensures disconnection from the electrical mains, with an opening gap of the con-
tacts that enables total disconnection in overvoltage category III conditions.

 

Said disconnection devices must be provided in the mains power supply in compliance 
with installation regulations.

The cable must not be cut of by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety regulations.

FUMES DISCHARGE

EXTERNAL EXHAUST HOOD (SUCTION)

In this version the fumes and vapours are discharged outside through 
the exhaust pipe.
To this end, the hood outlet itting must be connected via a pipe, to an 
external output.

The outlet pipe must have:
•  a diameter not less than that of the hood itting.
•  a slight slope downwards (drop) in the horizontal sections to prevent condensation from 

lowing back into the motor.

•  the minimum required number of bends.

•  the minimum required length to avoid vibrations and reduce the suction performance of 

the hood.

  You are required to insulate the pipes if it passes through cold environments.
  In the presence of motors with 800m

3

/h or higher, a check valve is present to prevent 

external air lowing back.

HOOD WITH INTERNAL RECIRCULATION (FILTERING)

In this model, the air passes through the charcoal ilters to be puriied 
and recycled in the environment.

Ensure that the active carbon ilters are assembled into the hood, if not, 
install them as indicated in the assembly instructions. 

In this version the check valve must not be assembled: remove it if it is on the air 
outlet itting of the motor.

ASSEMBLY INSTRUCTIONS

Intended only for qualiied personnel

The hood can be installed in various conigurations.

The generic assembly steps apply to all installations; for each case, follow 
the speciic steps provided for the required installation.

OPERATION

WHEN TO TURN ON THE HOOD?

Switch on the hood at least one minute before starting to cook to direct fumes and vapours 
towards the suction surface.
After cooking, leave the hood operating until complete extraction of all vapours and odours. 
By means of the Timer function, it is possible to set auto switch-of function which will allow 
the hood to turn of automatically after 15 minutes of operation.

WHICH SPEED IS TO BE SELECTED?

1st speed:

 maintains the circulation of clean air with low electricity consumption.

2nd speed:

 normal conditions of use.

3rd speed:

 presence of strong odours and vapours.

4th speed:

 rapid disposal of odours and vapours.

WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?

The metal ilters must be cleaned every 30 hours of operation. 
The active carbon ilters must be replaced every 3-4 months, depending on the use of the 
hood.
For further details refer to the 

“MAINTENANCE” 

section.

ELECTRONIC PUSHBUTTON PANEL

Motor ON/OFF

Upon start-up, the speed is that stored at the previous operation.

Increase speed from 1 to 4

Speed 4 is only active for a few min-
utes, then speed 3 activates.

The speeds are indicated by the LEDs 
on the keys:

 

Speed 1

 Speed 2

 Speed 3

 Speed 4 

("+" LED lashing)

Reduce speed from 4 to 1

 

Light on/of

TIMER

 (red LED lashing)

Auto switch-of after 15 min.
The function deactivates (red LED of ) if:
- The TIMER key (

) is pressed again.

- The ON/OFF key (

) is pressed.

FILTER ALARM

 (red LED steady on with (

) of)

Anti-grease ilter maintenance after approximately 30 hours of operation.
Press (

) the meter for 3 seconds to reset.

Содержание flipper

Страница 1: ...EN INSTRUCTIONS BOOKLET FR MODE D EMPLOI ES MANUAL DE INSTRUCCIONES IT LIBRETTO ISTRUZIONI lipper FDPLI36W5SW FDPLI36W5SB lipper...

Страница 2: ...510 mm 4 1 8 106 mm 16 405 mm 20 5 8 525 mm 4 1 2 115 mm 7 3 4 198 mm 7 7 8 200 mm 15 1 4 389 mm max 15 380 mm 13 3 4 348 mm 13 3 4 350 mm 1 1 8 29 mm 5 16 8 mm 1 8 6 mm 55lb 25 kg FLIPPER Cod FDPLI36...

Страница 3: ...e hood FR Sortie alternative arri re le moteur d passe de l arri re de la hotte de 3 8 10 mm ES Salida alternativa posterior el motor sobresale 3 8 10 mm en la parte posterior de la campana IT Uscita...

Страница 4: ...Installation avec sortie verticale Mesures pour l installation 1 Fixation de la hotte 2 ES Instalaci n con salida vertical Medidas para la instalaci n 1 Fijaci n de la campana 2 IT Installazione con u...

Страница 5: ...3 and suction pipe assembly 4 FR Installation du clapet anti retour 3 et montage du tuyau d aspiration 4 ES Instalaci n de la v lvula antirretorno 3 y montaje del tubo de aspiraci n 4 IT Installazion...

Страница 6: ...ing 6 FR Installation avec une sortie arri re Mesures pour l installation 5 Repositionnement du moteur 6 ES Instalaci n con salida posterior Medidas para la instalaci n 5 Reubicaci n del motor 6 IT In...

Страница 7: ...7 7 2 8 9 10 10 11 11 3 V7 x4 T 1 Panel control connector 5 Power cable 6 7 V8 x2 4 T EN Motor repositioning 7 FR Repositionnement du moteur 7 ES Reubicaci n del motor 7 IT Riposizionamento motore 7...

Страница 8: ...nillos de seguridad obligatorios IT Viti di sicurezza obbligatorie EN Check valve installation 8 Hood fastening 9 FR Installation du clapet anti retour 8 Fixation de la hotte 9 ES Instalaci n de la v...

Страница 9: ...9 G H 1 2 V3 x6 3 3 4 3 3 1 2 2 1 1 4 1 4 6 mm 1 4 6 mm 1 4 6 mm V4 x2 5 L H V5 x2 3 L 2 13 11 12 EN Optional chimney FR Chemin e en option ES Camino opcional IT Camino opzionale...

Страница 10: ...10 2 2 1 2 2 4 3 3 4 15 16 14 1 4 4 3 2 EN Assembly of optional ilter 15 16 FR Montage du iltre en option 15 16 ES Montaje del iltro opcional 15 16 IT Montaggio iltro opzionale 15 16...

Страница 11: ...1 2 2 4 3 3 4 18 19 2 1 V3 x2 EN Assembly of optional Carbon Zeo ilter 18 FR Montage du Carbon Zeo iltre 18 ES Montaje del iltro Carbon Zeo 18 IT Montaggio iltro Carbon Zeo 18 KACL941 3 3 4 3 3 1 2 2...

Страница 12: ...ing the or cleaning the equipment The Manufacturer declines all responsibility for any damage caused directly or in directly to persons things and pets as a consequence of failing to comply with the s...

Страница 13: ...length to avoid vibrations and reduce the suction performance of the hood You are required to insulate the pipes if it passes through cold environments In the presence of motors with 800m3 h or highe...

Страница 14: ...the environment The active carbon ilters must be replaced on average every 3 4 months under normal con ditions of use See assembly instructions to replace the active carbon ilters LIGHTING The range h...

Страница 15: ...onnes aux choses et aux animaux domestiques suite au non respect des mises en garde de s curit indiqu es dans ce manuel Il est tr s important que ce manuel d instructions soit conserv avec l appareil...

Страница 16: ...e au minimum pour viter toute vibration et r duire la capacit aspirante de la hotte Il est n cessaire d isoler la tuyauterie si elle passe par des endroits non chauf s Pour emp cher les retours d air...

Страница 17: ...se L air pur est ainsi ren voy dans la pi ce Les iltres au charbon actif doivent tre remplac s en moyenne tous les 3 4 mois dans des conditions d utilisation normales Pour le remplacement des iltres a...

Страница 18: ...eza en el mismo El Fabricante declina toda responsabilidad por posibles da os que puedan ser pro vocados directa o indirectamente a personas animales o cosas debido al incumpli miento de las advertenc...

Страница 19: ...nima indispensable para evitar vibraciones y reducir la capacidad aspirante de la campana Es necesario aislar la tuber a si pasa a trav s de ambientes fr os Para impedir retornos de aire desde el ext...

Страница 20: ...stituidos cada 3 4 meses en condiciones de uso normal Para sustituir los iltro de carb n activo consulte las instrucciones de montaje ILUMINACI N La campana cuenta con iluminaci n mediante bombillas d...

Страница 21: ...irettamente essere causati a persone cose ed animali domestici con seguenti alla mancata osservanza delle avvertenze di sicurezza indicate in questo libretto molto importante che questo libretto istru...

Страница 22: ...ca nel motore il numero minimo indispensabile di curve la lunghezza minima indispensabile per evitare vibrazioni e di ridurre la capacit aspiran te della cappa E necessario isolare la tubazione se pas...

Страница 23: ...2 SMALTIMENTO A FINE VITA Il simbolo del cestino barrato riportato sull apparecchiatura in suo possesso indi ca che il prodotto un RAEE cio un Riiuto derivante dalle Apparecchiature Elettriche ed Elet...

Страница 24: ...FALMEC S p A 31029 VITTORIO VENETO Treviso ITALY Zona Industriale Via dell Artigianato 42 www falmec com Code 110033057 Ed 00 2017 Code Serial Number...

Отзывы: