background image

INSTALLATION  MANUAL

falmecau.com

Downdraft

Содержание Downdraft Series

Страница 1: ...INSTALLATION MANUAL falmecau com Downdraft...

Страница 2: ...510 715 738 1026 max 400 220 92 84 341 103 275 109 90 1081 220 90 308 109 103 879 46 kg Downdraft 120 37 kg 109 341 92 798 726 824 738 1 5 336 275 104 715 max 400 781 781 220 90 92 82 237 390 5 Downd...

Страница 3: ...3 Downdraft 90 120 Downdraft 90 120 349 246 97 92 191 540mm quota minima con curva 90 Falmec 321 361 471 540mm using 90 bend Falmec 781 715 max 400 738 474 241 92 1 5 84 109 Remote motor...

Страница 4: ...4 396 510 510 737 879 Rear view side front hood 70 24 B 1 4 2 4 57 32 6 D 1 3 8 mm 6 mm Downdraft 90 120 Downdraft 90 120 Motor PIN INSTALLATION WITH BACK MOTOR...

Страница 5: ...5 810 mm 1110 mm 98 mm 60 mm 715 mm motor pin 738 mm max 1 2 7 0 m m 5 7 m m 2 1 Ideal size PRELIMINARY OPERATIONS Recess hole dimensions 1 fixing to the support surface 2...

Страница 6: ...6 230V 3seconds 230V 3 4 5 PRELIMINARY OPERATIONS PRELIMINARY OPERATIONS Temporary electrical connection 3 Opening the hood for installation 4 5...

Страница 7: ...7 Configuration with front motor Remove the cover 6 remove the metal side panels 7 fix motor KACL784 8 1 7 8 6 KACL 784...

Страница 8: ...8 Configuration with back motor Remove the cover 9 remove the metal side panels 10 fix motor KACL784 11 1 10 11 9 KACL 784...

Страница 9: ...9 Installing the carbon zeolite filter optional 12 Front motor 13 back motor 14 AIR AIR AIR AIR KACL 930 TYPE B TYPE A MAGNET TYPE A TYPE A 12 13 14 CARBON ZEO LITE FILTER INSTALLATION...

Страница 10: ...CL 798 15 Replace the original inlet 15 with the bracket fixing the motor to the hood 16 secure the motor to the hood if the air exhaust is on the front 17 For other directions see 18 19 6 OUTLET 16 1...

Страница 11: ...11 360 AIR 19 x 8 4 2 1 180 3 90 5 x 8 6 OUTLET Side movement of the air exhaust 18 KACL 798...

Страница 12: ...12 360 AIR 6 OUTLET Configuration with back motor 1 21 22 20 KACL 798...

Страница 13: ...13 Rectangular pipes 23 round pipes 24 90 220 Motor Motor 23 24 ONLY FALMEC MOTORS ONLY FALMEC MOTORS CONFIGURATION WITH REMOTE MOTOR...

Страница 14: ...14 25 Onboard motor 25 Remote motor 26 26 ELECTRICAL CONNECTION...

Страница 15: ...15 Magnets Brackets fixing to the TOP 27 Fixing the control unit to the hood 28 Hand anti crushing warning 29 29 28 27...

Страница 16: ...using the or cleaning the equipment The Manufacturer declines all responsibility for any damage caused directly or in directly to persons things and pets as a consequence of failing to comply with the...

Страница 17: ...sence of motors with 800m3 h or higher a check valve is present to prevent external air lowing back Deviation for Germany when the kitchen hood is used at the same time as appliances that are powered...

Страница 18: ...created by following the procedure below Disconnect the power to the hood before starting the procedure 1 CREATE A NEW CODE The procedure is to be carried out on the radio control Press LIGHT and TIM...

Страница 19: ...cedure Remove the ilter as described in the instructions Place the 4 ilters 3 x type A and 1 x type B in a domestic oven at 200 C for about 2 hours When the ilter has cooled down reit the 4 ilters ont...

Страница 20: ...ct by building materials of any kind will be required to be removed and reinstalled by the customer 10 PR Kitchens Washrooms has a service network in all metropolitan areas and most regional areas Whe...

Страница 21: ...21 NOTE NOTES...

Страница 22: ...22 NOTE NOTES...

Страница 23: ...23 NOTE NOTES...

Страница 24: ...o Treviso Italy falmec com Australia PR Kitchen Washroom Systems 83 Bangholme Rd Dandenong South VIC 3175 Australia 61 3 9700 9100 info prks com au New Zealand PR Kitchen Washroom Systems NZ P O Box 5...

Отзывы: